These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 25491846)

  • 1. New generation super alloy candidates for medical applications: corrosion behavior, cation release and biological evaluation.
    Reclaru L; Ziegenhagen R; Unger RE; Eschler PY; Constantin F
    Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():411-20. PubMed ID: 25491846
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative corrosion study of "Ni-free" austenitic stainless steels in view of medical applications.
    Reclaru L; Ziegenhagen R; Eschler PY; Blatter A; Lemaître J
    Acta Biomater; 2006 Jul; 2(4):433-44. PubMed ID: 16765883
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influences of passivating elements on the corrosion and biocompatibility of super stainless steels.
    Yoo YR; Jang SG; Oh KT; Kim JG; Kim YS
    J Biomed Mater Res B Appl Biomater; 2008 Aug; 86(2):310-20. PubMed ID: 18161790
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrochemical study of Type 304 and 316L stainless steels in simulated body fluids and cell cultures.
    Tang YC; Katsuma S; Fujimoto S; Hiromoto S
    Acta Biomater; 2006 Nov; 2(6):709-15. PubMed ID: 16935040
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro corrosion resistance of Lotus-type porous Ni-free stainless steels.
    Alvarez K; Hyun SK; Fujimoto S; Nakajima H
    J Mater Sci Mater Med; 2008 Nov; 19(11):3385-97. PubMed ID: 18545945
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cultures and co-cultures of human blood mononuclear cells and endothelial cells for the biocompatibility assessment of surface modified AISI 316L austenitic stainless steel.
    Stio M; Martinesi M; Treves C; Borgioli F
    Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():1081-91. PubMed ID: 27612806
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Properties of super stainless steels for orthodontic applications.
    Oh KT; Kim YS; Park YS; Kim KN
    J Biomed Mater Res B Appl Biomater; 2004 May; 69(2):183-94. PubMed ID: 15116408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biocompatibility evaluation of surface-treated AISI 316L austenitic stainless steel in human cell cultures.
    Martinesi M; Bruni S; Stio M; Treves C; Bacci T; Borgioli F
    J Biomed Mater Res A; 2007 Jan; 80(1):131-45. PubMed ID: 16983653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution.
    Assis SL; Rogero SO; Antunes RA; Padilha AF; Costa I
    J Biomed Mater Res B Appl Biomater; 2005 Apr; 73(1):109-16. PubMed ID: 15660438
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ni-Cr based dental alloys; Ni release, corrosion and biological evaluation.
    Reclaru L; Unger RE; Kirkpatrick CJ; Susz C; Eschler PY; Zuercher MH; Antoniac I; Lüthy H
    Mater Sci Eng C Mater Biol Appl; 2012 Aug; 32(6):1452-60. PubMed ID: 24364945
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion Resistance of Stainless Steels Intended to Come into Direct or Prolonged Contact with the Skin.
    Ziegenhagen R; Reclaru L; Ardelean LC; Grecu AF
    Materials (Basel); 2019 Mar; 12(6):. PubMed ID: 30934640
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of boron addition on injection molded 316L stainless steel: mechanical, corrosion properties and in vitro bioactivity.
    Bayraktaroglu E; Gulsoy HO; Gulsoy N; Er O; Kilic H
    Biomed Mater Eng; 2012; 22(6):333-49. PubMed ID: 23114463
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corrosion behavior of sensitized duplex stainless steel.
    Torres FJ; Panyayong W; Rogers W; Velasquez-Plata D; Oshida Y; Moore BK
    Biomed Mater Eng; 1998; 8(1):25-36. PubMed ID: 9713683
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Corrosion and haemocompatibility of 316L stainless steel with electroplated Rh film].
    Liu J; Yang D; Liang C; Guo L; Kong L; Cai Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Jun; 18(2):169-72. PubMed ID: 11450526
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In-vitro long term and electrochemical corrosion resistance of cold deformed nitrogen containing austenitic stainless steels in simulated body fluid.
    Talha M; Behera CK; Sinha OP
    Mater Sci Eng C Mater Biol Appl; 2014 Jul; 40():455-66. PubMed ID: 24857514
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro biocompatibility evaluation of surface-modified titanium alloys.
    Treves C; Martinesi M; Stio M; Gutiérrez A; Jiménez JA; López MF
    J Biomed Mater Res A; 2010 Mar; 92(4):1623-34. PubMed ID: 19437430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The corrosion and biological behaviour of titanium alloys in the presence of human lymphoid cells and MC3T3-E1 osteoblasts.
    Zhang YM; Chai F; Hornez JC; Li CL; Zhao YM; Traisnel M; Hildebrand HF
    Biomed Mater; 2009 Feb; 4(1):015004. PubMed ID: 18981540
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Duplex stainless steels for osteosynthesis devices.
    Cigada A; Rondelli G; Vicentini B; Giacomazzi M; Roos A
    J Biomed Mater Res; 1989 Sep; 23(9):1087-95. PubMed ID: 2777835
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of nitrogen and cold working on structural and mechanical behavior of Ni-free nitrogen containing austenitic stainless steels for biomedical applications.
    Talha M; Behera CK; Sinha OP
    Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():196-203. PubMed ID: 25492189
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.