These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

275 related articles for article (PubMed ID: 25492195)

  • 1. Surface engineering of a Zr-based bulk metallic glass with low energy Ar- or Ca-ion implantation.
    Huang L; Zhu C; Muntele CI; Zhang T; Liaw PK; He W
    Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():248-55. PubMed ID: 25492195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Ni-free ZrCuFeAlAg bulk metallic glass with potential for biomedical applications.
    Liu Y; Wang YM; Pang HF; Zhao Q; Liu L
    Acta Biomater; 2013 Jun; 9(6):7043-53. PubMed ID: 23429233
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Zr-based bulk metallic glass for future stent applications: Materials properties, finite element modeling, and in vitro human vascular cell response.
    Huang L; Pu C; Fisher RK; Mountain DJ; Gao Y; Liaw PK; Zhang W; He W
    Acta Biomater; 2015 Oct; 25():356-68. PubMed ID: 26162585
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Macrophage responses to a Zr-based bulk metallic glass.
    Huang L; Zhang T; Liaw PK; He W
    J Biomed Mater Res A; 2014 Oct; 102(10):3369-78. PubMed ID: 24166768
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biocompatible Ni-free Zr-based bulk metallic glasses with high-Zr-content: compositional optimization for potential biomedical applications.
    Hua N; Huang L; Chen W; He W; Zhang T
    Mater Sci Eng C Mater Biol Appl; 2014 Nov; 44():400-10. PubMed ID: 25280721
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro study on Zr-based bulk metallic glasses as potential biomaterials.
    Wang YB; Zheng YF; Wei SC; Li M
    J Biomed Mater Res B Appl Biomater; 2011 Jan; 96(1):34-46. PubMed ID: 21061358
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design, characterization and testing of Ti-based multicomponent coatings for load-bearing medical applications.
    Shtansky DV; Gloushankova NA; Sheveiko AN; Kharitonova MA; Moizhess TG; Levashov EA; Rossi F
    Biomaterials; 2005 Jun; 26(16):2909-24. PubMed ID: 15603786
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Responses of bone-forming cells on pre-immersed Zr-based bulk metallic glasses: Effects of composition and roughness.
    Huang L; Cao Z; Meyer HM; Liaw PK; Garlea E; Dunlap JR; Zhang T; He W
    Acta Biomater; 2011 Jan; 7(1):395-405. PubMed ID: 20709197
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enhanced antimicrobial properties, cytocompatibility, and corrosion resistance of plasma-modified biodegradable magnesium alloys.
    Zhao Y; Jamesh MI; Li WK; Wu G; Wang C; Zheng Y; Yeung KW; Chu PK
    Acta Biomater; 2014 Jan; 10(1):544-56. PubMed ID: 24140607
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tribological behavior of a Ni-free Zr-based bulk metallic glass with potential for biomedical applications.
    Hua N; Chen W; Wang W; Lu H; Ye X; Li G; Lin C; Huang X
    Mater Sci Eng C Mater Biol Appl; 2016 Sep; 66():268-277. PubMed ID: 27207063
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biocompatibility study on Ni-free Ti-based and Zr-based bulk metallic glasses.
    Li TH; Wong PC; Chang SF; Tsai PH; Jang JSC; Huang JC
    Mater Sci Eng C Mater Biol Appl; 2017 Jun; 75():1-6. PubMed ID: 28415381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tailoring surface properties of biomedical polymers by implantation of Ar and He ions.
    Manso M; Valsesia A; Lejeune M; Gilliland D; Ceccone G; Rossi F
    Acta Biomater; 2005 Jul; 1(4):431-40. PubMed ID: 16701824
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface Mechanoengineering of a Zr-Based Bulk Metallic Glass via Ar-Nanobubble Doping To Probe Cell Sensitivity to Rigid Materials.
    Huang L; Tian M; Wu D; Duscher G; Liaw PK; He W
    ACS Appl Mater Interfaces; 2017 Dec; 9(50):43429-43437. PubMed ID: 29171273
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biological relevance of ion energy in performance of human endothelial cells on ion-implanted flexible polyurethane surfaces.
    Ozkucur N; Richter E; Wetzel C; Funk RH; Monsees TK
    J Biomed Mater Res A; 2010 Apr; 93(1):258-68. PubMed ID: 19557788
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Zr61Ti2Cu25Al12 metallic glass for potential use in dental implants: biocompatibility assessment by in vitro cellular responses.
    Li J; Shi LL; Zhu ZD; He Q; Ai HJ; Xu J
    Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2113-21. PubMed ID: 23498239
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of calcium ion implantation on human bone cell interaction with titanium.
    Nayab SN; Jones FH; Olsen I
    Biomaterials; 2005 Aug; 26(23):4717-27. PubMed ID: 15763251
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Degradation of Zr-based bulk metallic glasses used in load-bearing implants: A tribocorrosion appraisal.
    Zhao GH; Aune RE; Mao H; Espallargas N
    J Mech Behav Biomed Mater; 2016 Jul; 60():56-67. PubMed ID: 26773648
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Antimicrobial behavior of Cu-bearing Zr-based bulk metallic glasses.
    Huang L; Fozo EM; Zhang T; Liaw PK; He W
    Mater Sci Eng C Mater Biol Appl; 2014 Jun; 39():325-9. PubMed ID: 24863231
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving biocompatibility of zirconia surface by incorporating Ca ions.
    Sasaki K; Hayashi T; Asakura M; Ando M; Kawai T; Ban S
    Dent Mater J; 2015; 34(3):336-44. PubMed ID: 25948140
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro biocompatibility of an ultrafine grained zirconium.
    Saldaña L; Méndez-Vilas A; Jiang L; Multigner M; González-Carrasco JL; Pérez-Prado MT; González-Martín ML; Munuera L; Vilaboa N
    Biomaterials; 2007 Oct; 28(30):4343-54. PubMed ID: 17624424
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.