184 related articles for article (PubMed ID: 25493523)
21. Lung 4D-IMRT treatment planning: an evaluation of three methods applied to four-dimensional data sets.
Ehler ED; Tomé WA
Radiother Oncol; 2008 Sep; 88(3):319-25. PubMed ID: 18703249
[TBL] [Abstract][Full Text] [Related]
22. A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.
Roland T; Hales R; McNutt T; Wong J; Simari P; Tryggestad E
Med Phys; 2012 Jan; 39(1):195-205. PubMed ID: 22225288
[TBL] [Abstract][Full Text] [Related]
23. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.
Admiraal MA; Schuring D; Hurkmans CW
Radiother Oncol; 2008 Jan; 86(1):55-60. PubMed ID: 18082905
[TBL] [Abstract][Full Text] [Related]
24. Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer.
Valdes G; Robinson C; Lee P; Morel D; Low D; Iwamoto KS; Lamb JM
Med Dosim; 2015; 40(1):64-9. PubMed ID: 25542785
[TBL] [Abstract][Full Text] [Related]
25. Motion-weighted target volume and dose-volume histogram: a practical approximation of four-dimensional planning and evaluation.
Zhang G; Feygelman V; Huang TC; Stevens C; Li W; Dilling T
Radiother Oncol; 2011 Apr; 99(1):67-72. PubMed ID: 21397967
[TBL] [Abstract][Full Text] [Related]
26. Dosimetric comparison of treatment plans based on free breathing, maximum, and average intensity projection CTs for lung cancer SBRT.
Tian Y; Wang Z; Ge H; Zhang T; Cai J; Kelsey C; Yoo D; Yin FF
Med Phys; 2012 May; 39(5):2754-60. PubMed ID: 22559646
[TBL] [Abstract][Full Text] [Related]
27. A preliminary investigation of re-evaluating the irradiation dose in hepatocellular carcinoma radiotherapy applying 4D CT and deformable registration.
Xu H; Gong G; Yin Y; Liu T
J Appl Clin Med Phys; 2021 Feb; 22(2):13-20. PubMed ID: 33452706
[TBL] [Abstract][Full Text] [Related]
28. A clinical 3D/4D CBCT-based treatment dose monitoring system.
Qin A; Gersten D; Liang J; Liu Q; Grill I; Guerrero T; Stevens C; Yan D
J Appl Clin Med Phys; 2018 Nov; 19(6):166-176. PubMed ID: 30306710
[TBL] [Abstract][Full Text] [Related]
29. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking.
Keall PJ; Joshi S; Vedam SS; Siebers JV; Kini VR; Mohan R
Med Phys; 2005 Apr; 32(4):942-51. PubMed ID: 15895577
[TBL] [Abstract][Full Text] [Related]
30. Comparing the accuracy of four-dimensional photon dose calculations with three-dimensional calculations using moving and deforming phantoms.
Vinogradskiy YY; Balter P; Followill DS; Alvarez PE; White RA; Starkschall G
Med Phys; 2009 Nov; 36(11):5000-6. PubMed ID: 19994509
[TBL] [Abstract][Full Text] [Related]
31. Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers.
Liu Q; Liang J; Zhou D; Krauss DJ; Chen PY; Yan D
Int J Radiat Oncol Biol Phys; 2018 Jul; 101(4):985-997. PubMed ID: 29976511
[TBL] [Abstract][Full Text] [Related]
32. Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT.
Liu G; Hu F; Ding X; Li X; Shao Q; Wang Y; Yang J; Quan H
Radiat Oncol; 2019 Jan; 14(1):1. PubMed ID: 30621744
[TBL] [Abstract][Full Text] [Related]
33. 4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters.
Sothmann T; Gauer T; Werner R
PLoS One; 2017; 12(2):e0172810. PubMed ID: 28231337
[TBL] [Abstract][Full Text] [Related]
34. The dosimetric differences in calculating lung SBRT plans on different image data sets: Comparison of the free breathing scan to both the average intensity projection scan and to the sum of calculations on each respiratory phase of the 4DCT scan.
Gaetani Liseo F; Lautenschlaeger T; Ewing M; Langer M
Med Dosim; 2019 Autumn; 44(3):291-299. PubMed ID: 30097226
[TBL] [Abstract][Full Text] [Related]
35. Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations.
Flampouri S; Jiang SB; Sharp GC; Wolfgang J; Patel AA; Choi NC
Phys Med Biol; 2006 Jun; 51(11):2763-79. PubMed ID: 16723765
[TBL] [Abstract][Full Text] [Related]
36. Potential dosimetric benefits of four-dimensional radiation treatment planning.
Starkschall G; Britton K; McAleer MF; Jeter MD; Kaus MR; Bzdusek K; Mohan R; Cox JD
Int J Radiat Oncol Biol Phys; 2009 Apr; 73(5):1560-5. PubMed ID: 19231098
[TBL] [Abstract][Full Text] [Related]
37. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion.
Rietzel E; Chen GT; Choi NC; Willet CG
Int J Radiat Oncol Biol Phys; 2005 Apr; 61(5):1535-50. PubMed ID: 15817360
[TBL] [Abstract][Full Text] [Related]
38. Evaluation of dosimetric uncertainty caused by MR geometric distortion in MRI-based liver SBRT treatment planning.
Han S; Yin FF; Cai J
J Appl Clin Med Phys; 2019 Feb; 20(2):43-50. PubMed ID: 30697915
[TBL] [Abstract][Full Text] [Related]
39. The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer.
Wu QJ; Thongphiew D; Wang Z; Chankong V; Yin FF
Med Phys; 2008 Apr; 35(4):1440-51. PubMed ID: 18491539
[TBL] [Abstract][Full Text] [Related]
40. Influence of Respiratory Motion on Dose Distribution in Gastric Mucosa-associated Lymphoid Tissue Lymphoma Radiotherapy.
Matsumoto T; Toya R; Shimohigashi Y; Yamaguchi K; Watakabe T; Matsuyama T; Fukugawa Y; Kai Y; Oya N
Anticancer Res; 2024 Feb; 44(2):687-694. PubMed ID: 38307577
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]