These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 25495865)

  • 21. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer.
    Medeiros FA; Weinreb RN
    J Glaucoma; 2006 Oct; 15(5):364-70. PubMed ID: 16988597
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment.
    Pensyl D; Sullivan-Mee M; Torres-Monte M; Halverson K; Qualls C
    Eye (Lond); 2012 Oct; 26(10):1349-56. PubMed ID: 22878449
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Factors influencing intermethod agreement between goldmann applanation, pascal dynamic contour, and ocular response analyzer tonometry.
    Sullivan-Mee M; Lewis SE; Pensyl D; Gerhardt G; Halverson KD; Qualls C
    J Glaucoma; 2013 Aug; 22(6):487-95. PubMed ID: 22407388
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes.
    Hager A; Loge K; Schroeder B; Füllhas MO; Wiegand W
    J Glaucoma; 2008 Aug; 17(5):361-5. PubMed ID: 18703945
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature.
    Franco S; Lira M
    Clin Exp Optom; 2009 Nov; 92(6):469-75. PubMed ID: 19694758
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST.
    Tejwani S; Dinakaran S; Joshi A; Shetty R; Sinha Roy A
    Indian J Ophthalmol; 2015 Nov; 63(11):815-20. PubMed ID: 26669331
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of intraocular pressure in LASIK and LASEK patients using the Reichert Ocular Response Analyzer and Goldmann applanation tonometry.
    Kirwan C; O'Keefe M
    J Refract Surg; 2008 Apr; 24(4):366-70. PubMed ID: 18500086
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Evaluation of the Ocular Response Analyzer in ocular hypertension, glaucoma, and normal populations. Prospective study on 329 eyes].
    Streho M; Dariel R; Giraud JM; Verret C; Fenolland JR; Crochelet O; May F; Maurin JF; Renard JP
    J Fr Ophtalmol; 2008 Dec; 31(10):953-60. PubMed ID: 19107070
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Corvis ST Tonometer for Measuring Postoperative IOP in LASIK Patients.
    Hong J; Yu Z; Jiang C; Zhou X; Liu Z; Sun X; Xu J
    Optom Vis Sci; 2015 May; 92(5):589-95. PubMed ID: 25871871
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Impact of dehydration and fasting on intraocular pressure and corneal biomechanics measured by the Ocular Response Analyzer.
    Uysal BS; Duru N; Ozen U; Arikan Yorgun M; Akcay E; Caglayan M; Cagil N
    Int Ophthalmol; 2018 Apr; 38(2):451-457. PubMed ID: 28255839
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The relationship between measurement method and corneal structure on apparent intraocular pressure in glaucoma and ocular hypertension.
    Nessim M; Mollan SP; Wolffsohn JS; Laiquzzaman M; Sivakumar S; Hartley S; Shah S
    Cont Lens Anterior Eye; 2013 Apr; 36(2):57-61. PubMed ID: 23253796
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of Rebound Tonometry, Perkins Applanation Tonometry and Ocular Response Analyser in Mucopolysaccharidosis Patients.
    Wasielica-Poslednik J; Butsch C; Lampe C; Elflein H; Lamparter J; Weyer V; Pitz S
    PLoS One; 2015; 10(8):e0133586. PubMed ID: 26317991
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Goldmann Applanation Tonometer Versus Ocular Response Analyzer for Measuring Intraocular Pressure After Descemet Stripping Automated Endothelial Keratoplasty.
    Feizi S; Faramarzi A; Masoudi A; Azari AA; Veisi A
    Cornea; 2018 Nov; 37(11):1370-1375. PubMed ID: 29877927
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of corneal biomechanical properties using an ocular response analyser to examine aphakic and pseudophakic patients after congenital cataract surgery.
    Simsek T; Soba DO; Tırhış MH; Yılmazbaş P; Öztürk F
    Acta Ophthalmol; 2016 May; 94(3):e198-203. PubMed ID: 26521752
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in patients with glaucoma.
    Vandewalle E; Vandenbroeck S; Stalmans I; Zeyen T
    Eur J Ophthalmol; 2009; 19(5):783-9. PubMed ID: 19787598
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Influence of ocular pulse amplitude on ocular response analyzer measurements.
    Xu G; Lam DS; Leung CK
    J Glaucoma; 2011 Aug; 20(6):344-9. PubMed ID: 20852442
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: corneal biomechanical and tonometric implications.
    Moreno-Montañés J; Maldonado MJ; García N; Mendiluce L; García-Gómez PJ; Seguí-Gómez M
    Invest Ophthalmol Vis Sci; 2008 Mar; 49(3):968-74. PubMed ID: 18326720
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of cornea on intraocular pressure measurement by ICARE PRO and ORA.
    Pluháček F; Unzeitigová A; Marešová K; Rybář J
    Cesk Slov Oftalmol; 2019; 75(3):111-118. PubMed ID: 31779459
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An ultra-high-speed Scheimpflug camera for evaluation of corneal deformation response and its impact on IOP measurement.
    Leung CK; Ye C; Weinreb RN
    Invest Ophthalmol Vis Sci; 2013 Apr; 54(4):2885-92. PubMed ID: 23482466
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
    Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D
    Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.