1. Evaluation of the Microsemi CRP, an automated hematology analyzer for rapid 3-part WBC differential and CRP using whole blood.
Nomura N; Saito K; Ikeda M; Yuasa S; Pastore M; Chabert C; Kono E; Sakai A; Tanaka H; Ikemoto T; Takubo T
Int J Lab Hematol; 2015 Aug; 37(4):466-73. PubMed ID: 25496069
[TBL] [Abstract][Full Text] [Related]
2. Basic evaluation of Pentra MS CRP, a new automated hematology analyzer for rapid 5-part WBC differential and CRP using a small volume of whole blood.
Inaba T; Nomura N; Ishizuka K; Yoshioka K; Takahashi M; Yuasa S; Saito K; Fujitomo Y; Nakanishi M; Fujita N
Int J Lab Hematol; 2015 Apr; 37(2):208-16. PubMed ID: 24915801
[TBL] [Abstract][Full Text] [Related]
3. [Utility of microsemi LC-667CRP in point of care testing system for acute inflammatory disease].
Inaba T; Yuasa S; Taniguchi H; Nakashima K; Nagaoka H; Fujita N
Rinsho Byori; 2010 Jul; 58(7):664-9. PubMed ID: 20715509
[TBL] [Abstract][Full Text] [Related]
4. Evaluation and comparison of the new Mindray BC-6200 hematology analyzer with ADVIA 2120i.
Kulik K; Kwiecień I; Chełstowska B; Rutkowska E; Rzepecki P
Int J Lab Hematol; 2021 Jun; 43(3):395-402. PubMed ID: 33270987
[TBL] [Abstract][Full Text] [Related]
5. [Basic Evaluation of Microsemi LC-767CRP as POCT Model for Simultaneous Measurement of CBC and CRP].
Inaba T; Ikeda M; Saitoh K; Yuasa S; Mishima N; Ogura K; Oku N; Kodama M; Fujitomo Y; Nakanishi M; Fujita N
Rinsho Byori; 2016 Feb; 64(2):152-6. PubMed ID: 27311278
[TBL] [Abstract][Full Text] [Related]
6. Performance evaluation of new Abbott Alinity hq hematology analyzer.
Woo KS; Jeong IH; An GD; Lim HH; Han JY
Int J Lab Hematol; 2019 Oct; 41(5):657-663. PubMed ID: 31271528
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of Mindray BC-5000 hematology analyzer: a new miniature 5-part WBC differential instrument.
Xiang D; Yue J; Lan Y; Sha C; Ren S; Li Y; Li M; Wang C
Int J Lab Hematol; 2015 Oct; 37(5):597-605. PubMed ID: 25944368
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of the automated hematology analyzer ADVIA® 120 for cerebrospinal fluid analysis and usage of unique hemolysis reagent.
Tanada H; Ikemoto T; Masutani R; Tanaka H; Takubo T
Int J Lab Hematol; 2014 Feb; 36(1):83-91. PubMed ID: 23937551
[TBL] [Abstract][Full Text] [Related]
9. Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement.
Srivastava A; Koul V; Dwivedi SN; Upadhyaya AD; Ahuja A; Saxena R
Int J Lab Hematol; 2015 Aug; 37(4):483-5. PubMed ID: 25418886
[TBL] [Abstract][Full Text] [Related]
10. Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.
Guerti K; Vertessen F; Daniëls L; Van Der Planken M
Int J Lab Hematol; 2009 Apr; 31(2):132-41. PubMed ID: 19267810
[TBL] [Abstract][Full Text] [Related]
11. Development of a new point-of-care testing system for measuring white blood cell and C-reactive protein levels in whole blood samples.
Kotani K; Minami T; Abe T; Sato J; Taniguchi N; Yamada T
Clin Chim Acta; 2014 Jun; 433():145-9. PubMed ID: 24642344
[TBL] [Abstract][Full Text] [Related]
12. Performance evaluation of the Abbott CELL-DYN Emerald for use as a bench-top analyzer in a research setting.
Khoo TL; Xiros N; Guan F; Orellana D; Holst J; Joshua DE; Rasko JE
Int J Lab Hematol; 2013 Aug; 35(4):447-56. PubMed ID: 23279758
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.
Bhuta UM; Ulstein H
Lab Hematol; 2003; 9(3):167-74. PubMed ID: 14521325
[TBL] [Abstract][Full Text] [Related]
14. Fast bedside measurement of blood count and C-reactive protein in newborns compared with conventional methods.
Papa F; Rongioletti M; Majolini MB; Collegiani V; Vaccarella C; Notarmuzi ML; Cortesi M; Pasqualetti P; Cicchese M; Agostino R; Liumbruno GM
Clin Lab; 2012; 58(9-10):951-7. PubMed ID: 23163111
[TBL] [Abstract][Full Text] [Related]
15. Performance evaluation of the XPEN60 CRP&SAA, a novel automated hematology analyzer, in detecting complete blood count, C-reactive protein, and serum amyloid A.
Zong Z; Kan L; Luo Y; Wang C; Wang X; Wang M; Xiong D; Zhang X
J Clin Lab Anal; 2020 Sep; 34(9):e23395. PubMed ID: 32519385
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of Mindray BC-3600 hematology analyzer in a university hospital.
Shu G; Lu H; Du H; Shi J; Wu G
Int J Lab Hematol; 2013 Feb; 35(1):61-9. PubMed ID: 22925195
[TBL] [Abstract][Full Text] [Related]
17. Blast flagging of the Sysmex XN-10 hematology analyzer with supervised cell image analysis: Impact on quality parameters.
Petrone J; Jackups R; Eby CS; Shimer G; Anderson J; Frater JL
Int J Lab Hematol; 2019 Oct; 41(5):601-606. PubMed ID: 31162809
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the automated hematology analyzer Sysmex XT-2000iV™ compared to the ADVIA® 2120 for its use in dogs, cats, and horses: Part I--precision, linearity, and accuracy of complete blood cell count.
Bauer N; Nakagawa J; Dunker C; Failing K; Moritz A
J Vet Diagn Invest; 2011 Nov; 23(6):1168-80. PubMed ID: 22362798
[TBL] [Abstract][Full Text] [Related]
19. Immunoturbidimetric Assay for Determination of Peripheral Blood C Reactive Protein on the Pentra MS CRP Hematology Analyzer.
Xiang D; Yue J; Liu P; Sun J; Ren S; Sha C; Wang C
Clin Lab; 2019 Jun; 65(6):. PubMed ID: 31232024
[TBL] [Abstract][Full Text] [Related]
20. [The relevance of a simultaneous measurement of WBC and CRP as a POCT(point of care testing) of the inflammatory markers running title: the POCT(point of care testing) of WBC and CRP].
Miyazaki M
Rinsho Byori; 2002 Nov; 50(11):1029-34. PubMed ID: 12491598
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]