BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

304 related articles for article (PubMed ID: 25502182)

  • 1. Newborn blood spot screening test using multiplexed real-time PCR to simultaneously screen for spinal muscular atrophy and severe combined immunodeficiency.
    Taylor JL; Lee FK; Yazdanpanah GK; Staropoli JF; Liu M; Carulli JP; Sun C; Dobrowolski SF; Hannon WH; Vogt RF
    Clin Chem; 2015 Feb; 61(2):412-9. PubMed ID: 25502182
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dried Blood Spot Screening System for Spinal Muscular Atrophy with Allele-Specific Polymerase Chain Reaction and Melting Peak Analysis.
    Wijaya YOS; Nishio H; Niba ETE; Shiroshita T; Kato M; Bouike Y; Tode C; Ar Rochmah M; Harahap NIF; Nurputra DK; Okamoto K; Saito T; Takeuchi A; Lai PS; Yamaguchi S; Shinohara M
    Genet Test Mol Biomarkers; 2021 Apr; 25(4):293-301. PubMed ID: 33877896
    [No Abstract]   [Full Text] [Related]  

  • 3. Multiplex Droplet Digital PCR Method Applicable to Newborn Screening, Carrier Status, and Assessment of Spinal Muscular Atrophy.
    Vidal-Folch N; Gavrilov D; Raymond K; Rinaldo P; Tortorelli S; Matern D; Oglesbee D
    Clin Chem; 2018 Dec; 64(12):1753-1761. PubMed ID: 30352867
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detection of Spinal Muscular Atrophy Using a Duplexed Real-Time PCR Approach With Locked Nucleic Acid-Modified Primers.
    Pan J; Zhang C; Teng Y; Zeng S; Chen S; Liang D; Li Z; Wu L
    Ann Lab Med; 2021 Jan; 41(1):101-107. PubMed ID: 32829585
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Newborn Screening for Spinal Muscular Atrophy: DNA Preparation from Dried Blood Spot and DNA Polymerase Selection in PCR.
    Takeuchi A; Tode C; Nishino M; Wijaya YOS; Niba ETE; Awano H; Takeshima Y; Saito T; Saito K; Lai PS; Bouike Y; Nishio H; Shinohara M
    Kobe J Med Sci; 2019 Nov; 65(3):E95-E99. PubMed ID: 32029694
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Genetic screening of spinal muscular atrophy using a real-time modified COP-PCR technique with dried blood-spot DNA.
    Ar Rochmah M; Harahap NIF; Niba ETE; Nakanishi K; Awano H; Morioka I; Iijima K; Saito T; Saito K; Lai PS; Takeshima Y; Takeuchi A; Bouike Y; Okamoto M; Nishio H; Shinohara M
    Brain Dev; 2017 Oct; 39(9):774-782. PubMed ID: 28522225
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spinal Muscular Atrophy: Advanced Version of Screening System with Real-Time mCOP-PCR and PCR-RFLP for SMN1 Deletion.
    Niba ETE; Rochmah MA; Harahap NIF; Awano H; Morioka I; Iijima K; Takeshima Y; Saito T; Saito K; Takeuchi A; Lai PS; Bouike Y; Matsuo M; Nishio H; Shinohara M
    Kobe J Med Sci; 2019 Jul; 65(2):E49-E53. PubMed ID: 31956256
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spinal Muscular Atrophy: New Screening System with Real-Time mCOP-PCR and PCR-RFLP for SMN1 Deletion.
    Niba ETE; Rochmah MA; Harahap NIF; Awano H; Morioka I; Iijima K; Takeshima Y; Saito T; Saito K; Takeuchi A; Lai PS; Bouike Y; Matsuo M; Nishio H; Shinohara M
    Kobe J Med Sci; 2019 Jul; 65(2):E44-E48. PubMed ID: 31956255
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High Incidence of Severe Combined Immunodeficiency Disease in Saudi Arabia Detected Through Combined T Cell Receptor Excision Circle and Next Generation Sequencing of Newborn Dried Blood Spots.
    Al-Mousa H; Al-Dakheel G; Jabr A; Elbadaoui F; Abouelhoda M; Baig M; Monies D; Meyer B; Hawwari A; Dasouki M
    Front Immunol; 2018; 9():782. PubMed ID: 29713328
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SMA Diagnosis: Detection of SMN1 Deletion with Real-Time mCOP-PCR System Using Fresh Blood DNA.
    Niba ETE; Ar Rochmah M; Harahap NIF; Awano H; Morioka I; Iijima K; Saito T; Saito K; Takeuchi A; Lai PS; Bouike Y; Nishio H; Shinohara M
    Kobe J Med Sci; 2017 Dec; 63(3):E80-E83. PubMed ID: 29434179
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Presymptomatic Diagnosis of Spinal Muscular Atrophy Through Newborn Screening.
    Chien YH; Chiang SC; Weng WC; Lee NC; Lin CJ; Hsieh WS; Lee WT; Jong YJ; Ko TM; Hwu WL
    J Pediatr; 2017 Nov; 190():124-129.e1. PubMed ID: 28711173
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spinal muscular atrophy patient detection and carrier screening using dried blood spots on filter paper.
    Harahap NI; Harahap IS; Kaszynski RH; Nurputra DK; Hartomo TB; Pham HT; Yamamoto T; Morikawa S; Nishimura N; Rusdi I; Widiastuti R; Nishio H
    Genet Test Mol Biomarkers; 2012 Feb; 16(2):123-9. PubMed ID: 21942573
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incorporating Spinal Muscular Atrophy Analysis by Next-Generation Sequencing into a Comprehensive Multigene Panel for Neuromuscular Disorders.
    Tan CA; Westbrook MJ; Truty R; Kvitek DJ; Kennemer M; Winder TL; Shieh PB
    Genet Test Mol Biomarkers; 2020 Oct; 24(10):616-624. PubMed ID: 32721234
    [No Abstract]   [Full Text] [Related]  

  • 14. SMA screening system using dried blood spots on filter paper: application of COP-PCR to the SMN1 deletion test.
    Kato N; Sa'Adah N; Ar Rochmah M; Harahap NI; Nurputra DK; Sato H; Sadewa AH; Astuti I; Haryana SM; Saito T; Saito K; Nishimura N; Nishio H; Takeuchi A
    Kobe J Med Sci; 2015 Jan; 60(4):E78-85. PubMed ID: 25791416
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a Multiplex Real-Time PCR Assay for the Newborn Screening of SCID, SMA, and XLA.
    Gutierrez-Mateo C; Timonen A; Vaahtera K; Jaakkola M; Hougaard DM; Bybjerg-Grauholm J; Baekvad-Hansen M; Adamsen D; Filippov G; Dallaire S; Goldfarb D; Schoener D; Wu R
    Int J Neonatal Screen; 2019 Dec; 5(4):39. PubMed ID: 33072998
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nested PCR Amplification Secures DNA Template Quality and Quantity in Real-time mCOP-PCR Screening for SMA.
    Wijaya YOS; Niba ETE; Rochmah MA; Harahap NIF; Awano H; Takeshima Y; Saito T; Saito K; Takeuchi A; Lai PS; Bouike Y; Nishio H; Shinohara M
    Kobe J Med Sci; 2019 Jul; 65(2):E54-E58. PubMed ID: 31956257
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-throughput genetic newborn screening for spinal muscular atrophy by rapid nucleic acid extraction from dried blood spots and 384-well qPCR.
    Czibere L; Burggraf S; Fleige T; Glück B; Keitel LM; Landt O; Durner J; Röschinger W; Hohenfellner K; Wirth B; Müller-Felber W; Vill K; Becker M
    Eur J Hum Genet; 2020 Jan; 28(1):23-30. PubMed ID: 31363188
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Droplet Digital PCR Method for Severe Combined Immunodeficiency Newborn Screening.
    Vidal-Folch N; Milosevic D; Majumdar R; Gavrilov D; Matern D; Raymond K; Rinaldo P; Tortorelli S; Abraham RS; Oglesbee D
    J Mol Diagn; 2017 Sep; 19(5):755-765. PubMed ID: 28826609
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-throughput multiplexed T-cell-receptor excision circle quantitative PCR assay with internal controls for detection of severe combined immunodeficiency in population-based newborn screening.
    Gerstel-Thompson JL; Wilkey JF; Baptiste JC; Navas JS; Pai SY; Pass KA; Eaton RB; Comeau AM
    Clin Chem; 2010 Sep; 56(9):1466-74. PubMed ID: 20660142
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Multiplex, Droplet Digital PCR Assay for the Detection of T-Cell Receptor Excision Circles and Kappa-Deleting Recombination Excision Circles.
    Profaizer T; Slev P
    Clin Chem; 2020 Jan; 66(1):229-238. PubMed ID: 31672859
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.