BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 25504268)

  • 1. Stand-alone mapping using different transluminal mapping catheters--an accurate and safe way to isolate all pulmonary veins with the cryoballoon?
    Schade A; Schumacher B; Dietrich JW; Langbein A; Groschup G; Koucky K; Krug J; Stahl C; Müller P; Nentwich K; Roos M; Deneke T
    J Interv Card Electrophysiol; 2015 Jan; 42(1):33-41. PubMed ID: 25504268
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Verification of pulmonary vein isolation during single transseptal cryoballoon ablation: a comparison between the classical circular mapping catheter and the inner lumen mapping catheter.
    Chierchia GB; Namdar M; Sarkozy A; Sorgente A; de Asmundis C; Casado-Arroyo R; Capulzini L; Bayrak F; Rodriguez-Mañero M; Ricciardi D; Rao JY; Overeinder I; Paparella G; Brugada P
    Europace; 2012 Dec; 14(12):1708-14. PubMed ID: 22772051
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: a feasibility study.
    Chierchia GB; de Asmundis C; Namdar M; Westra S; Kuniss M; Sarkozy A; Bayrak F; Ricciardi D; Casado-Arroyo R; Rodriguez Manero M; Rao JY; Smeets J; Brugada P
    Europace; 2012 Jul; 14(7):962-7. PubMed ID: 22411731
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of electrical ostial pulmonary vein isolation verified with a spiral inner lumen mapping catheter during second-generation cryoballoon ablation.
    Miyazaki S; Kajiyama T; Watanabe T; Taniguchi H; Nakamura H; Hamaya R; Kusa S; Igarashi M; Hachiya H; Hirao K; Iesaka Y
    J Cardiovasc Electrophysiol; 2017 Aug; 28(8):870-875. PubMed ID: 28497857
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Single transseptal big Cryoballoon pulmonary vein isolation using an inner lumen mapping catheter.
    Chun KJ; Bordignon S; Gunawardene M; Urban V; Kulikoglu M; Schulte-Hahn B; Nowak B; Schmidt B
    Pacing Clin Electrophysiol; 2012 Nov; 35(11):1304-11. PubMed ID: 22882344
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The time course of exit and entrance block during cryoballoon pulmonary vein isolation.
    Andrade J; Khairy P; Dubuc M; Deyell MW; Roy D; Talajic M; Thibault B; Guerra PG; Rivard L; Macle L
    Europace; 2014 Apr; 16(4):500-4. PubMed ID: 23918789
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.
    Anter E; Tschabrunn CM; Contreras-Valdes FM; Li J; Josephson ME
    Heart Rhythm; 2015 Sep; 12(9):1927-34. PubMed ID: 26001505
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulmonary vein re-mapping after cryoballoon ablation for atrial fibrillation.
    Yokoyama K; Tokuda M; Matsuo S; Isogai R; Tokutake K; Kato M; Narui R; Tanigawa S; Yamashita S; Inada K; Yoshimura M; Yamane T
    Europace; 2018 Jun; 20(6):943-948. PubMed ID: 29016768
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cryoballoon ablation for pulmonary vein isolation in patients with atrial fibrillation: preliminary results using novel short-tip cryoballoon.
    Koektuerk B; Yorgun H; Koektuerk O; Turan CH; Aksoy MN; Turan RG; Gorr E; Bansmann PM; Hoppe C; Horlitz M
    J Interv Card Electrophysiol; 2016 Oct; 47(1):91-98. PubMed ID: 27189156
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures.
    Ciconte G; Velagić V; Mugnai G; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Sieira J; Di Giovanni G; Baltogiannis G; Brugada P; de Asmundis C; Chierchia GB
    Europace; 2016 Jan; 18(1):71-7. PubMed ID: 26445821
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success.
    Dorwarth U; Schmidt M; Wankerl M; Krieg J; Straube F; Hoffmann E
    J Interv Card Electrophysiol; 2011 Dec; 32(3):205-11. PubMed ID: 21594628
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pressure-guided cryoballoon isolation of the pulmonary veins for the treatment of paroxysmal atrial fibrillation.
    Siklódy CH; Minners J; Allgeier M; Allgeier HJ; Jander N; Keyl C; Weber R; Schiebeling-Römer J; Kalusche D; Arentz T
    J Cardiovasc Electrophysiol; 2010 Feb; 21(2):120-5. PubMed ID: 19793145
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An apparent way of achieving proof of pulmonary vein disconnection during cryoballoon ablation.
    Schwagten B; DE Greef Y; Acou WJ; Stockman D
    Pacing Clin Electrophysiol; 2012 Nov; 35(11):e337-40. PubMed ID: 21819420
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Single-catheter approach to pulmonary vein reisolation in selected patients : Data from a prospective registry.
    Lauschke J; Schneider R; Wissmann J; Tischer T; Bänsch D
    Herz; 2016 Nov; 41(7):625-629. PubMed ID: 26883899
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cryoballoon pulmonary vein isolation with real-time recordings from the pulmonary veins.
    Chun KR; Fürnkranz A; Metzner A; Schmidt B; Tilz R; Zerm T; Köster I; Nuyens D; Wissner E; Ouyang F; Kuck KH
    J Cardiovasc Electrophysiol; 2009 Nov; 20(11):1203-10. PubMed ID: 19602018
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reduction of procedure duration and radiation exposure with a dedicated inner lumen mapping catheter during pulmonary vein cryoablation.
    Peyrol M; Sbragia P; Quatre A; Orabona M; Casalta AC; Boccara G; Zerrouk Z; Guenoun M; Lévy S; Paganelli F
    Pacing Clin Electrophysiol; 2013 Jan; 36(1):24-30. PubMed ID: 23078045
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study.
    Reddy VY; Sediva L; Petru J; Skoda J; Chovanec M; Chitovova Z; Di Stefano P; Rubin E; Dukkipati S; Neuzil P
    J Cardiovasc Electrophysiol; 2015 May; 26(5):493-500. PubMed ID: 25644659
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a novel spiral mapping catheter for real-time recordings from the pulmonary veins during cryoballoon ablation of atrial fibrillation.
    Kühne M; Knecht S; Altmann D; Ammann P; Schaer B; Osswald S; Sticherling C
    Heart Rhythm; 2013 Feb; 10(2):241-6. PubMed ID: 23041571
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial experience with the high-density mesh ablation catheter for pulmonary vein isolation.
    De Greef Y; Stockman D; Duytschaever M; Vandekerckhove Y; Tavernier R
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1286-93. PubMed ID: 19796345
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon.
    Pott A; Petscher K; Messemer M; Rottbauer W; Dahme T
    J Interv Card Electrophysiol; 2016 Dec; 47(3):333-339. PubMed ID: 27448816
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.