These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 25510349)

  • 1. Provisional hybrid 2-stent Strategy utilizing bioresorbable vascular scaffold and drug-eluting metal stent: "T-stenting and small protrusion" technique.
    Miyazaki T; Latib A; Colombo A
    Catheter Cardiovasc Interv; 2015 Oct; 86(4):682-5. PubMed ID: 25510349
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The absorb bioresorbable vascular scaffold in coronary bifurcations: insights from bench testing.
    Džavík V; Colombo A
    JACC Cardiovasc Interv; 2014 Jan; 7(1):81-8. PubMed ID: 24332424
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials.
    Doi H; Maehara A; Mintz GS; Yu A; Wang H; Mandinov L; Popma JJ; Ellis SG; Grube E; Dawkins KD; Weissman NJ; Turco MA; Ormiston JA; Stone GW
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1269-75. PubMed ID: 20129555
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Severe Neointimal Hyperplasia of Neoplastic Carina Following Bioresorbable Scaffold Implantation Using T-Stenting and Small Protrusion Technique: Insights From Optical Frequency Domain Imaging.
    Kawamoto H; Ruparelia N; Figini F; Latib A; Colombo A
    JACC Cardiovasc Interv; 2015 Nov; 8(13):e207-9. PubMed ID: 26476605
    [No Abstract]   [Full Text] [Related]  

  • 6. Bioresorbable vascular scaffold use for coronary bifurcation lesions: A substudy from GHOST EU registry.
    Naganuma T; Colombo A; Lesiak M; Capodanno D; Gori T; Nef H; Caramanno G; Naber C; Di Mario C; Ruparelia N; Capranzano P; Wiebe J; Araszkiewicz A; Geraci S; Kawamoto H; Pyxaras S; Mattesini A; Münzel T; Tamburino C; Latib A
    Catheter Cardiovasc Interv; 2017 Jan; 89(1):47-56. PubMed ID: 27414021
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modified T-stenting with intentional protrusion of the side-branch stent within the main vessel stent to ensure ostial coverage and facilitate final kissing balloon: the T-stenting and small protrusion technique (TAP-stenting). Report of bench testing and first clinical Italian-Korean two-centre experience.
    Burzotta F; Gwon HC; Hahn JY; Romagnoli E; Choi JH; Trani C; Colombo A
    Catheter Cardiovasc Interv; 2007 Jul; 70(1):75-82. PubMed ID: 17585382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bioresorbable vascular scaffold restenosis: intravascular imaging evaluation.
    Fabris E; Kilic ID; Caiazzo G; Serdoz R; Foin N; Sinagra G; Di Mario C
    J Cardiovasc Med (Hagerstown); 2016 Dec; 17 Suppl 2():e132-e135. PubMed ID: 26599682
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sequential Proximal Optimizing Technique in Provisional Bifurcation Stenting With Everolimus-Eluting Bioresorbable Vascular Scaffold: Fractal Coronary Bifurcation Bench for Comparative Test Between Absorb and XIENCE Xpedition.
    Derimay F; Souteyrand G; Motreff P; Guerin P; Pilet P; Ohayon J; Darremont O; Rioufol G; Finet G
    JACC Cardiovasc Interv; 2016 Jul; 9(13):1397-406. PubMed ID: 27388830
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term clinical and angiographic outcomes after implantation of sirolimus-eluting stents with a "modified mini-crush" technique in coronary bifurcation lesions.
    Yang HM; Tahk SJ; Woo SI; Lim HS; Choi BJ; Choi SY; Yoon MH; Park JS; Zheng M; Hwang GS; Kang SJ; Shin JH
    Catheter Cardiovasc Interv; 2009 Jul; 74(1):76-84. PubMed ID: 19360861
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The ABSORB bioresorbable vascular scaffold: A novel, fully resorbable drug-eluting stent: Current concepts and overview of clinical evidence.
    Rizik DG; Hermiller JB; Kereiakes DJ
    Catheter Cardiovasc Interv; 2015 Oct; 86(4):664-77. PubMed ID: 26386235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Randomized study of the crush technique versus provisional side-branch stenting in true coronary bifurcations: the CACTUS (Coronary Bifurcations: Application of the Crushing Technique Using Sirolimus-Eluting Stents) Study.
    Colombo A; Bramucci E; Saccà S; Violini R; Lettieri C; Zanini R; Sheiban I; Paloscia L; Grube E; Schofer J; Bolognese L; Orlandi M; Niccoli G; Latib A; Airoldi F
    Circulation; 2009 Jan; 119(1):71-8. PubMed ID: 19103990
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility and efficacy of bioresorbable vascular scaffolds use for the treatment of in-stent restenosis and a bifurcation lesion in a heavily calcified diffusely diseased vessel.
    Naganuma T; Costopoulos C; Latib A; Sato K; Miyazaki T; Colombo A
    JACC Cardiovasc Interv; 2014 May; 7(5):e45-6. PubMed ID: 24746654
    [No Abstract]   [Full Text] [Related]  

  • 14. Clinical outcomes following bioresorbable scaffold implantation for bifurcation lesions: Overall outcomes and comparison between provisional and planned double stenting strategy.
    Kawamoto H; Latib A; Ruparelia N; Miyazaki T; Sticchi A; Naganuma T; Sato K; Figini F; Chieffo A; Carlino M; Montorfano M; Colombo A
    Catheter Cardiovasc Interv; 2015 Oct; 86(4):644-52. PubMed ID: 26013748
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A next-generation bioresorbable coronary scaffold system: from bench to first clinical evaluation: 6- and 12-month clinical and multimodality imaging results.
    Verheye S; Ormiston JA; Stewart J; Webster M; Sanidas E; Costa R; Costa JR; Chamie D; Abizaid AS; Pinto I; Morrison L; Toyloy S; Bhat V; Yan J; Abizaid A
    JACC Cardiovasc Interv; 2014 Jan; 7(1):89-99. PubMed ID: 24139932
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence and short-term clinical outcomes of small side branch occlusion after implantation of an everolimus-eluting bioresorbable vascular scaffold: an interim report of 435 patients in the ABSORB-EXTEND single-arm trial in comparison with an everolimus-eluting metallic stent in the SPIRIT first and II trials.
    Muramatsu T; Onuma Y; García-García HM; Farooq V; Bourantas CV; Morel MA; Li X; Veldhof S; Bartorelli A; Whitbourn R; Abizaid A; Serruys PW;
    JACC Cardiovasc Interv; 2013 Mar; 6(3):247-57. PubMed ID: 23517836
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Kissing drug eluting balloons for in-stent restenosis complicating bifurcations treated with drug-eluting stents.
    Raja Y; Doshi SN; Townend JN
    Catheter Cardiovasc Interv; 2012 Feb; 79(3):392-6. PubMed ID: 21805583
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Absorb Bioresorbable Vascular Scaffold in Complex Coronary Bifurcation Interventions: Insights From an In Vivo Multimodality Imaging Study.
    Bennett J; Vanhaverbeke M; Vanden Driessche N; Adriaenssens T; Hiltrop N; Desmet W; Sinnaeve P; Dubois C
    Circ Cardiovasc Interv; 2016 Aug; 9(8):. PubMed ID: 27512090
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Management of distal/bifurcation left main restenosis after drug eluting stents implantation: single center experience.
    Rigatelli G; Cardaioli P; Dell'Avvocata F; Giordan M; Vassilev D; Fraccaro C; Roncon L; Faggian G
    Cardiovasc Revasc Med; 2014 Mar; 15(2):76-9. PubMed ID: 24560299
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A true bifurcational stenosis treated with a bioresorbable vascular scaffold and a drug-eluting metallic stent: Degradable meets durable.
    Wiebe J; Hamm C; Nef H
    Catheter Cardiovasc Interv; 2015 Jun; 85(7):1184-8. PubMed ID: 25581885
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.