These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 25511064)

  • 21. Ion release from orthodontic brackets in 3 mouthwashes: an in-vitro study.
    Danaei SM; Safavi A; Roeinpeikar SM; Oshagh M; Iranpour S; Omidkhoda M
    Am J Orthod Dentofacial Orthop; 2011 Jun; 139(6):730-4. PubMed ID: 21640878
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparative study on corrosion behaviour of Nitinol and stainless steel orthodontic wires in simulated saliva solution in presence of fluoride ions.
    Mirjalili M; Momeni M; Ebrahimi N; Moayed MH
    Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2084-93. PubMed ID: 23498236
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The effects of lubrication on the static frictional resistance of orthodontic brackets.
    Al-Mansouri N; Palmer G; Moles DR; Jones SP
    Aust Orthod J; 2011 Nov; 27(2):132-8. PubMed ID: 22372269
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Exposure to the oral environment enhances the corrosion of metal orthodontic appliances caused by fluoride-containing products: Cytotoxicity, metal ion release, and surface roughness.
    Chantarawaratit PO; Yanisarapan T
    Am J Orthod Dentofacial Orthop; 2021 Jul; 160(1):101-112. PubMed ID: 33966956
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Static frictional resistances of polycrystalline ceramic brackets with metal slot inserts.
    Rajakulendran J; Jones S
    Aust Orthod J; 2006 Nov; 22(2):147-52. PubMed ID: 17203579
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biodegradation of the orthodontic bracket system.
    Maijer R; Smith DC
    Am J Orthod Dentofacial Orthop; 1986 Sep; 90(3):195-8. PubMed ID: 3463194
    [TBL] [Abstract][Full Text] [Related]  

  • 27. In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.
    Eliades T; Athanasiou AE
    Angle Orthod; 2002 Jun; 72(3):222-37. PubMed ID: 12071606
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Topographic and chemical surface modifications to metal brackets after a period in the mouth.
    Houb-Dine A; Bahije L; Oualalou Y; Benyahia H; Zaoui F
    Int Orthod; 2017 Sep; 15(3):515-528. PubMed ID: 28755866
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Galvanic corrosion between various combinations of orthodontic brackets and archwires.
    Bakhtari A; Bradley TG; Lobb WK; Berzins DW
    Am J Orthod Dentofacial Orthop; 2011 Jul; 140(1):25-31. PubMed ID: 21724083
    [TBL] [Abstract][Full Text] [Related]  

  • 30. In vitro determination of genotoxicity and cytotoxicity induced by stainless steel brackets with and without surface coating in cultures of oral mucosal cells.
    Ahuja D; Jose NP; Kamal R; Panduranga V; Nambiar S; Isloor AM
    BMC Oral Health; 2024 Oct; 24(1):1233. PubMed ID: 39415190
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires.
    Kim H; Johnson JW
    Angle Orthod; 1999 Feb; 69(1):39-44. PubMed ID: 10022183
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The effect of fluoride ions on the corrosion behaviour of Ti metal, and Ti6-Al-7Nb and Ti-6Al-4V alloys in artificial saliva.
    Milošev I; Kapun B; Selih VS
    Acta Chim Slov; 2013; 60(3):543-55. PubMed ID: 24169708
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Corrosion-related changes on Ti-based orthodontic brackets in acetic NaF solutions: surface morphology, microhardness, and element release.
    Kang EH; Park SB; Kim HI; Kwon YH
    Dent Mater J; 2008 Jul; 27(4):555-60. PubMed ID: 18833769
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An in vitro comparison of nickel and chromium release from brackets.
    Haddad AC; Tortamano A; Souza AL; Oliveira PV
    Braz Oral Res; 2009; 23(4):399-406. PubMed ID: 20027447
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An investigation of the corrosion behavior of zinc-coated stainless steel orthodontic wires: the effect of physical vapor deposition method.
    Karandish M; Hajipour N; Yazdani H; Mahdavi M; Rahsepar M
    BMC Oral Health; 2024 May; 24(1):501. PubMed ID: 38725023
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An overview of orthodontic material degradation in oral cavity.
    Chaturvedi TP; Upadhayay SN
    Indian J Dent Res; 2010; 21(2):275-84. PubMed ID: 20657101
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances.
    Petoumenou E; Arndt M; Keilig L; Reimann S; Hoederath H; Eliades T; Jäger A; Bourauel C
    Am J Orthod Dentofacial Orthop; 2009 Jan; 135(1):59-65. PubMed ID: 19121502
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of metal release from new and recycled bracket-archwire combinations.
    Gürsoy S; Acar AG; Seşen C
    Angle Orthod; 2005 Jan; 75(1):92-4. PubMed ID: 15747821
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Galvanic corrosion of Class II amalgam restorations in contact with orthodontic brackets/bands.
    Beague TP
    N Y State Dent J; 1992 Nov; 58(9):48-9. PubMed ID: 1436891
    [No Abstract]   [Full Text] [Related]  

  • 40. Pure titanium orthodontic brackets.
    Hamula DW; Hamula W; Sernetz F
    J Clin Orthod; 1996 Mar; 30(3):140-4. PubMed ID: 8975013
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.