These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

290 related articles for article (PubMed ID: 25521914)

  • 1. A feasibility study of Fricke dosimetry as an absorbed dose to water standard for 192Ir HDR sources.
    deAlmeida CE; Ochoa R; Lima MC; David MG; Pires EJ; Peixoto JG; Salata C; Bernal MA
    PLoS One; 2014; 9(12):e115155. PubMed ID: 25521914
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy.
    El Gamal I; Cojocaru C; Mainegra-Hing E; McEwen M
    Phys Med Biol; 2015 Jun; 60(11):4481-95. PubMed ID: 25988983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validating Fricke dosimetry for the measurement of absorbed dose to water for HDR
    Salata C; David MG; de Almeida CE; El Gamal I; Cojocaru C; Mainegra-Hing E; McEwen M
    Phys Med Biol; 2018 Apr; 63(8):085004. PubMed ID: 29488467
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quality assurance of HDR 192Ir sources using a Fricke dosimeter.
    Austerlitz C; Mota H; Almeida CE; Allison R; Sibata C
    Med Phys; 2007 Apr; 34(4):1348-53. PubMed ID: 17500465
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Absorbed dose distribution measurements in brachytherapy using ferrous sulphate gel and magnetic resonance imaging.
    Olsen DR; Hellesnes J
    Br J Radiol; 1994 Nov; 67(803):1121-6. PubMed ID: 7820406
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry: numerical and experimental proof-of-principle.
    Sarfehnia A; Stewart K; Seuntjens J
    Med Phys; 2007 Dec; 34(12):4957-61. PubMed ID: 18196821
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources.
    Antonovic L; Gustafsson H; Carlsson GA; Carlsson Tedgren A
    Med Phys; 2009 Jun; 36(6):2236-47. PubMed ID: 19610313
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Direct measurement of absorbed dose to water in HDR 192Ir brachytherapy: water calorimetry, ionization chamber, Gafchromic film, and TG-43.
    Sarfehnia A; Kawrakow I; Seuntjens J
    Med Phys; 2010 Apr; 37(4):1924-32. PubMed ID: 20443514
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
    Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ
    Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a water calorimetry-based standard for absorbed dose to water in HDR 192Ir brachytherapy.
    Sarfehnia A; Seuntjens J
    Med Phys; 2010 Apr; 37(4):1914-23. PubMed ID: 20443513
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
    Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
    Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of the correction factors used in Fricke dosimetry for HDR
    David MG; Salata C; de Almeida CE
    Phys Med; 2021 Apr; 84():50-55. PubMed ID: 33845419
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.
    Zilio VO; Joneja OP; Popowski Y; Rosenfeld A; Chawla R
    Med Phys; 2006 Jun; 33(6):1532-9. PubMed ID: 16872060
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.
    Tölli H; Johansson KA
    Phys Med Biol; 1998 Nov; 43(11):3183-94. PubMed ID: 9832010
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sci-Sat AM: Brachy - 03: Feasibility study of the determination of absorbed dose to water using a fricke based system.
    Gamal IE; Cojocaru C; Ross C; Marchington D; McEwen M
    Med Phys; 2012 Jul; 39(7Part4):4645. PubMed ID: 28516646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of absorbed dose-to-water for an HDR (192)Ir source with ionization chambers in a sandwich setup.
    Araki F; Kouno T; Ohno T; Kakei K; Yoshiyama F; Kawamura S
    Med Phys; 2013 Sep; 40(9):092101. PubMed ID: 24007170
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical note: fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism.
    Lliso F; Pérez-Calatayud J; Carmona V; Ballester F; Puchades V; Granero D
    Med Phys; 2003 Apr; 30(4):651-4. PubMed ID: 12722817
    [TBL] [Abstract][Full Text] [Related]  

  • 20. EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources.
    Taylor RE; Rogers DW
    Med Phys; 2008 Nov; 35(11):4933-44. PubMed ID: 19070227
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.