BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

75 related articles for article (PubMed ID: 25533109)

  • 1. Comparison of the renal hyperemic effects of papaverine and dopamine in patients with renal artery stenosis.
    Protasiewicz M; Początek K; Poręba R; Derkacz A; Podgórski M; Gosławska K; Szymańska-Chabowska A; Mazur G; Mysiak A; Witkowski A
    J Am Soc Hypertens; 2015 Jan; 9(1):9-14. PubMed ID: 25533109
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Kidney microcirculation response to adenosine stimulation in renal artery stenosis.
    Protasiewicz M; Początek K; Podgórski M; Poręba R; Derkacz A; Gosławska K; Kwiatkowska W; Mazur G; Mysiak A; Januszewicz A
    Blood Press; 2015; 24(5):293-7. PubMed ID: 26114734
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prognostic value of renal fractional flow reserve in blood pressure response after renal artery stenting (PREFER study).
    Kądziela J; Januszewicz A; Prejbisz A; Michałowska I; Januszewicz M; Florczak E; Kalińczuk Ł; Norwa-Otto B; Warchoł E; Witkowski A
    Cardiol J; 2013; 20(4):418-22. PubMed ID: 23913461
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Usefulness of translesional pressure gradient and pharmacological provocation for the assessment of intermediate renal artery disease.
    Jones NJ; Bates ER; Chetcuti SJ; Lederman RJ; Grossman PM
    Catheter Cardiovasc Interv; 2006 Sep; 68(3):429-34. PubMed ID: 16892443
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Renal fractional flow reserve: a hemodynamic evaluation of moderate renal artery stenoses.
    Subramanian R; White CJ; Rosenfield K; Bashir R; Almagor Y; Meerkin D; Shalman E
    Catheter Cardiovasc Interv; 2005 Apr; 64(4):480-6. PubMed ID: 15789382
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship between hemodynamic parameters of renal artery stenosis and the changes of kidney function after renal artery stenting in patients with hypertension and preserved renal function.
    Kądziela J; Prejbisz A; Michałowska I; Adamczak M; Warchoł-Celińska E; Pregowska-Chwała B; Januszewicz M; Więcek A; Januszewicz A; Witkowski A
    Blood Press; 2015 Feb; 24(1):30-4. PubMed ID: 25268986
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of renal artery stenosis using both resting pressures ratio and fractional flow reserve: relationship to angiography and ultrasonography.
    Kadziela J; Witkowski A; Januszewicz A; Cedro K; Michałowska I; Januszewicz M; Kabat M; Prejbisz A; Kalińczuk L; Zieleń P; Michel-Rowicka K; Warchoł E; Rużyłło W
    Blood Press; 2011 Aug; 20(4):211-7. PubMed ID: 21309656
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physiological assessment of renal artery stenosis: comparisons of resting with hyperemic renal pressure measurements.
    Kapoor N; Fahsah I; Karim R; Jevans AJ; Leesar MA
    Catheter Cardiovasc Interv; 2010 Nov; 76(5):726-32. PubMed ID: 20931666
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial experience with the use of fractional flow reserve in the hemodynamic evaluation of transplant renal artery stenosis.
    Gomes Júnior MPM; Alves CMR; Barbosa AHP; Caixeta A; Batista MC; Pestana JOM; Carvalho AC
    Catheter Cardiovasc Interv; 2018 Mar; 91(4):820-826. PubMed ID: 29411509
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Translesional pressure gradients to predict blood pressure response after renal artery stenting in patients with renovascular hypertension.
    Mangiacapra F; Trana C; Sarno G; Davidavicius G; Protasiewicz M; Muller O; Ntalianis A; Misonis N; Van Vlem B; Heyndrickx GR; De Bruyne B
    Circ Cardiovasc Interv; 2010 Dec; 3(6):537-42. PubMed ID: 21078879
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation between noninvasive and endovascular Doppler in patients with atherosclerotic renal artery stenosis: a pilot study.
    Slovut DP; Lookstein R; Bacharach JM; Olin JW
    Catheter Cardiovasc Interv; 2006 Mar; 67(3):426-33. PubMed ID: 16502400
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis and comparison of pressure gradients and ratios for predicting iliac stenosis.
    Archie JP
    Ann Vasc Surg; 1994 May; 8(3):271-80. PubMed ID: 8043361
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of renal flow and flow reserve in humans.
    Manoharan G; Pijls NH; Lameire N; Verhamme K; Heyndrickx GR; Barbato E; Wijns W; Madaric J; Tielbeele X; Bartunek J; De Bruyne B
    J Am Coll Cardiol; 2006 Feb; 47(3):620-5. PubMed ID: 16458147
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prediction of hypertension improvement after stenting of renal artery stenosis: comparative accuracy of translesional pressure gradients, intravascular ultrasound, and angiography.
    Leesar MA; Varma J; Shapira A; Fahsah I; Raza ST; Elghoul Z; Leonard AC; Meganathan K; Ikram S
    J Am Coll Cardiol; 2009 Jun; 53(25):2363-71. PubMed ID: 19539148
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predicting blood pressure improvement in hypertensive patients after renal artery stent placement: renal fractional flow reserve.
    Mitchell JA; Subramanian R; White CJ; Soukas PA; Almagor Y; Stewart RE; Rosenfield K
    Catheter Cardiovasc Interv; 2007 Apr; 69(5):685-9. PubMed ID: 17351955
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Renal artery stenosis in patients with resistant hypertension.
    Protasiewicz M; Kądziela J; Początek K; Poręba R; Podgórski M; Derkacz A; Prejbisz A; Mysiak A; Januszewicz A; Witkowski A
    Am J Cardiol; 2013 Nov; 112(9):1417-20. PubMed ID: 24135303
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changes in renal blood flow reserve after angioplasty of renal artery stenosis in hypertensive patients.
    Mounier-Vehier C; Cocheteux B; Haulon S; Devos P; Lions C; Gautier C; Carre A; Beregi JP
    Kidney Int; 2004 Jan; 65(1):245-50. PubMed ID: 14675056
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Utility of a 0.014" pressure-sensing guidewire to assess renal artery translesional systolic pressure gradients.
    Colyer WR; Cooper CJ; Burket MW; Thomas WJ
    Catheter Cardiovasc Interv; 2003 Jul; 59(3):372-7. PubMed ID: 12822163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of intravenous adenosine to intracoronary papaverine for calculation of pressure-derived fractional flow reserve.
    van der Voort PH; van Hagen E; Hendrix G; van Gelder B; Bech JW; Pijls NH
    Cathet Cardiovasc Diagn; 1996 Oct; 39(2):120-5. PubMed ID: 8922309
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of pulmonary flow reserve and pulmonary index of microcirculatory resistance for detection of pulmonary microvascular obstruction.
    Ilsar R; Chawantanpipat C; Chan KH; Dobbins TA; Waugh R; Hennessy A; Celermajer DS; Ng MK
    PLoS One; 2010 Mar; 5(3):e9601. PubMed ID: 20231900
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.