BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 25544663)

  • 1. Application of the Monte Carlo efficiency transfer method to an HPGe detector with the purpose of environmental samples measurement.
    Morera-Gómez Y; Cartas-Aguila HA; Alonso-Hernández CM; Bernal-Castillo JL; Guillén-Arruebarrena A
    Appl Radiat Isot; 2015 Mar; 97():59-62. PubMed ID: 25544663
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.
    Chagren S; Tekaya MB; Reguigui N; Gharbi F
    Appl Radiat Isot; 2016 Jan; 107():359-365. PubMed ID: 26623928
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method.
    Vargas MJ; Díaz NC; Sánchez DP
    Appl Radiat Isot; 2003 Jun; 58(6):707-12. PubMed ID: 12798381
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo simulation of the full energy peak efficiency of an HPGe detector.
    Khan W; Zhang Q; He C; Saleh M
    Appl Radiat Isot; 2018 Jan; 131():67-70. PubMed ID: 29173810
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Corrections of HPGe detector efficiency curve due to true coincidence summing by program EFFTRAN and by Monte Carlo simulations.
    Knezevic J; Mrdja D; Hansman J; Bikit K; Forkapic S; Bikit I; Velimirovic D; Kuzmanovic P
    Appl Radiat Isot; 2022 Nov; 189():110421. PubMed ID: 36037728
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of the HPGe detector efficiency in measurements of radioactivity in extended environmental samples.
    Montalván Olivares DM; Guevara MVM; Velasco FG
    Appl Radiat Isot; 2017 Dec; 130():34-42. PubMed ID: 28942326
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Study of the response of an ORTEC GMX45 HPGe detector with a multi-radionuclide volume source using Monte Carlo simulations.
    Saraiva A; Oliveira C; Reis M; Portugal L; Paiva I; Cruz C
    Appl Radiat Isot; 2016 Jul; 113():47-52. PubMed ID: 27131096
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4.
    Giubrone G; Ortiz J; Gallardo S; Martorell S; Bas MC
    J Environ Radioact; 2016 Jul; 158-159():114-8. PubMed ID: 27085040
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The determination of the efficiency of a Compton suppressed HPGe detector using Monte Carlo simulations.
    McNamara AL; Heijnis H; Fierro D; Reinhard MI
    J Environ Radioact; 2012 Apr; 106():1-7. PubMed ID: 22304994
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Maximising the sensitivity of a γ spectrometer for low-energy, low-activity radionuclides using Monte Carlo simulations.
    Britton R; Burnett JL; Davies AV; Regan PH
    J Environ Radioact; 2014 Aug; 134():1-5. PubMed ID: 24631843
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo calculations of the HPGe detector efficiency for radioactivity measurement of large volume environmental samples.
    Azbouche A; Belgaid M; Mazrou H
    J Environ Radioact; 2015 Aug; 146():119-24. PubMed ID: 25982445
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The first experimental test of the MEFFTRAN software on HPGe detector calibration for environmental samples.
    Nikolic JK; Rajacic M; Todorovic D; Vidmar T
    J Environ Radioact; 2016 Dec; 165():191-196. PubMed ID: 27736653
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gamma-ray efficiency of a HPGe detector as a function of energy and geometry.
    Challan MB
    Appl Radiat Isot; 2013 Dec; 82():166-9. PubMed ID: 24007787
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation of a well-type HPGe detector for samples both in the hole and on top of the endcap.
    Unno Y; Furukawa R; Yunoki A
    Appl Radiat Isot; 2017 Aug; 126():154-157. PubMed ID: 28233596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulation of the self-absorption corrections for natural samples in gamma-ray spectrometry.
    Vargas MJ; Timón AF; Díaz NC; Sánchez DP
    Appl Radiat Isot; 2002 Dec; 57(6):893-8. PubMed ID: 12406634
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Re-construction of a HPGe detector precise modeling for efficiency calibration.
    Zhang C; Hu G; Zeng J; Xiang Q; Guo X; Gong J
    Appl Radiat Isot; 2022 Feb; 180():110059. PubMed ID: 34929611
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume samples.
    Saegusa J; Kawasaki K; Mihara A; Ito M; Yoshida M
    Appl Radiat Isot; 2004 Dec; 61(6):1383-90. PubMed ID: 15388137
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors.
    Laborie JM; Le Petit G ; Abt D; Girard M
    Appl Radiat Isot; 2000 Jul; 53(1-2):57-62. PubMed ID: 10879838
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of the Monte Carlo method for the calibration of an in situ gamma spectrometer.
    Tzika F; Kontogeorgakos D; Vasilopoulou T; Stamatelatos IE
    Appl Radiat Isot; 2010; 68(7-8):1441-4. PubMed ID: 19945289
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimating thickness of the inner dead-layer of n-type HPGe detector.
    Chuong HD; Thanh TT; Ngoc Trang le T; Nguyen VH; Tao CV
    Appl Radiat Isot; 2016 Oct; 116():174-7. PubMed ID: 27552123
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.