236 related articles for article (PubMed ID: 25548890)
21. Hearing Outcomes with Percutaneous and Transcutaneous BAHA® Technology in Conductive and Mixed Hearing Loss.
Tobia A; Yehudai N; Khnifes R; Shpak T; Roth O; Khayr R; Luntz M
Otol Neurotol; 2021 Oct; 42(9):1382-1389. PubMed ID: 34528924
[TBL] [Abstract][Full Text] [Related]
22. Improvement of speech perception in quiet and in noise without decreasing localization abilities with the bone conduction device Bonebridge.
Weiss R; Leinung M; Baumann U; Weißgerber T; Rader T; Stöver T
Eur Arch Otorhinolaryngol; 2017 May; 274(5):2107-2115. PubMed ID: 28032241
[TBL] [Abstract][Full Text] [Related]
23. Indication criteria and outcomes with the Bonebridge transcutaneous bone-conduction implant.
Riss D; Arnoldner C; Baumgartner WD; Blineder M; Flak S; Bachner A; Gstoettner W; Hamzavi JS
Laryngoscope; 2014 Dec; 124(12):2802-6. PubMed ID: 25142577
[TBL] [Abstract][Full Text] [Related]
24. Clinical and functional results after implantation of the bonebridge, a semi-implantable, active transcutaneous bone conduction device, in children and adults.
Seiwerth I; Fröhlich L; Schilde S; Götze G; Plontke SK; Rahne T
Eur Arch Otorhinolaryngol; 2022 Jan; 279(1):101-113. PubMed ID: 33674927
[TBL] [Abstract][Full Text] [Related]
25. Multicenter Clinical Trial of Vibroplasty Couplers to Treat Mixed/Conductive Hearing Loss: First Results.
Zahnert T; Löwenheim H; Beutner D; Hagen R; Ernst A; Pau HW; Zehlicke T; Kühne H; Friese N; Tropitzsch A; Lüers JC; Mlynski R; Todt I; Hüttenbrink KB
Audiol Neurootol; 2016; 21(4):212-222. PubMed ID: 27351868
[TBL] [Abstract][Full Text] [Related]
26. A new bone conduction hearing aid to predict hearing outcome with an active implanted device.
Canale A; Boggio V; Albera A; Ravera M; Caranzano F; Lacilla M; Albera R
Eur Arch Otorhinolaryngol; 2019 Aug; 276(8):2165-2170. PubMed ID: 31053966
[TBL] [Abstract][Full Text] [Related]
27. Strategies of active middle ear implants for hearing rehabilitation in congenital aural atresia.
Verhaert N; Fuchsmann C; Tringali S; Lina-Granade G; Truy E
Otol Neurotol; 2011 Jun; 32(4):639-45. PubMed ID: 21436753
[TBL] [Abstract][Full Text] [Related]
28. Incus footplate assembly: Indication and surgical outcome.
Park M; Han S; Choi BY; Chang SO; Kim CS; Koo JW
Laryngoscope; 2016 Nov; 126(11):2569-2573. PubMed ID: 26863914
[TBL] [Abstract][Full Text] [Related]
29. Vibroplasty in Severe Congenital or Acquired Meatal Stenosis by Coupling an Active Middle Ear Implant to the Short Process of the Incus.
Thomas JP; Voelter C; Neumann K; Dazert S
Otol Neurotol; 2017 Aug; 38(7):996-1004. PubMed ID: 28538078
[TBL] [Abstract][Full Text] [Related]
30. [Relative value of BAHA testing for the postoperative audiological outcome].
Gründer I; Seidl RO; Ernst A; Todt I
HNO; 2008 Oct; 56(10):1020-4. PubMed ID: 17879076
[TBL] [Abstract][Full Text] [Related]
31. Outcomes after Application of Active Bone Conducting Implants.
Koro E; Werner M
Audiol Neurootol; 2019; 24(4):197-205. PubMed ID: 31499490
[TBL] [Abstract][Full Text] [Related]
32. A Comparative Study of a Novel Adhesive Bone Conduction Device and Conventional Treatment Options for Conductive Hearing Loss.
Skarzynski PH; Ratuszniak A; Osinska K; Koziel M; Krol B; Cywka KB; Skarzynski H
Otol Neurotol; 2019 Aug; 40(7):858-864. PubMed ID: 31295197
[TBL] [Abstract][Full Text] [Related]
33. The Sophono bone-conduction system: Surgical, audiologic, and quality-of-life outcomes.
Mclean T; Pai I; Philipatos A; Gordon M
Ear Nose Throat J; 2017 Jul; 96(7):E28-E33. PubMed ID: 28719716
[TBL] [Abstract][Full Text] [Related]
34. A Comparative Study of Audiologic Outcomes for Two Transcutaneous Bone-Anchored Hearing Devices.
Powell HR; Rolfe AM; Birman CS
Otol Neurotol; 2015 Sep; 36(9):1525-31. PubMed ID: 26375976
[TBL] [Abstract][Full Text] [Related]
35. Active bone conduction system: outcomes with the Bonebridge transcutaneous device.
Bianchin G; Bonali M; Russo M; Tribi L
ORL J Otorhinolaryngol Relat Spec; 2015; 77(1):17-26. PubMed ID: 25661010
[TBL] [Abstract][Full Text] [Related]
36. Hearing results in pediatric patients with chronic otitis media after ossicular reconstruction with partial ossicular replacement prostheses and total ossicular replacement prostheses.
Murphy TP
Laryngoscope; 2000 Apr; 110(4):536-44. PubMed ID: 10763997
[TBL] [Abstract][Full Text] [Related]
37. Middle ear implant in conductive and mixed congenital hearing loss in children.
Roman S; Denoyelle F; Farinetti A; Garabedian EN; Triglia JM
Int J Pediatr Otorhinolaryngol; 2012 Dec; 76(12):1775-8. PubMed ID: 22985678
[TBL] [Abstract][Full Text] [Related]
38. Comparison of sound processing strategies for osseointegrated bone conduction implants in mixed hearing loss: multiple-channel nonlinear versus single-channel linear processing.
Desmet JB; Bosman AJ; Snik AF; Lambrechts P; Hol MK; Mylanus EA; De Bodt M; Van de Heyning P
Otol Neurotol; 2013 Jun; 34(4):598-603. PubMed ID: 23615167
[TBL] [Abstract][Full Text] [Related]
39. Simultaneous bilateral transcutaneous bone conduction device implantation: sound localisation and speech perception in children with bilateral conductive hearing loss.
Chen P; Yang L; Yang J; Wang D; Li Y; Zhao C; Liu Y; Gao M; Zhu J; Li S; Zhao S
J Laryngol Otol; 2022 Oct; 136(10):939-946. PubMed ID: 35570567
[TBL] [Abstract][Full Text] [Related]
40. Retrospective Analysis of Hearing-Impaired Adult Patients Treated With an Active Transcutaneous Bone Conduction Implant.
Rader T; Stöver T; Lenarz T; Maier H; Zahnert T; Beleites T; Hagen R; Mlynski R; Baumgartner WD
Otol Neurotol; 2018 Aug; 39(7):874-881. PubMed ID: 29847467
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]