132 related articles for article (PubMed ID: 25549931)
1. Predictors of respiratory-induced lung tumour motion measured on four-dimensional computed tomography.
Tan KV; Thomas R; Hardcastle N; Pham D; Kron T; Foroudi F; Ball D; Te Marvelde L; Bressel M; Siva S
Clin Oncol (R Coll Radiol); 2015 Apr; 27(4):197-204. PubMed ID: 25549931
[TBL] [Abstract][Full Text] [Related]
2. Systematic evaluation of lung tumor motion using four-dimensional computed tomography.
Sarudis S; Karlsson Hauer A; Nyman J; Bäck A
Acta Oncol; 2017 Apr; 56(4):525-530. PubMed ID: 28075183
[TBL] [Abstract][Full Text] [Related]
3. Both four-dimensional computed tomography and four-dimensional cone beam computed tomography under-predict lung target motion during radiotherapy.
Steiner E; Shieh CC; Caillet V; Booth J; O'Brien R; Briggs A; Hardcastle N; Jayamanne D; Szymura K; Eade T; Keall P
Radiother Oncol; 2019 Jun; 135():65-73. PubMed ID: 31015172
[TBL] [Abstract][Full Text] [Related]
4. 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm.
Li Y; Ma JL; Chen X; Tang FW; Zhang XZ
Radiat Oncol; 2016 Nov; 11(1):152. PubMed ID: 27846900
[TBL] [Abstract][Full Text] [Related]
5. Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer.
Liu HH; Balter P; Tutt T; Choi B; Zhang J; Wang C; Chi M; Luo D; Pan T; Hunjan S; Starkschall G; Rosen I; Prado K; Liao Z; Chang J; Komaki R; Cox JD; Mohan R; Dong L
Int J Radiat Oncol Biol Phys; 2007 Jun; 68(2):531-40. PubMed ID: 17398035
[TBL] [Abstract][Full Text] [Related]
6. The use of respiratory-correlated four-dimensional CT where kidney motion has the potential to impact upon the radiotherapy planning process.
Gawthrop JB; Gill S
J Med Imaging Radiat Oncol; 2012 Dec; 56(6):689-95. PubMed ID: 23210590
[TBL] [Abstract][Full Text] [Related]
7. Variation in Lung Tumour Breathing Motion between Planning Four-dimensional Computed Tomography and Stereotactic Ablative Radiotherapy Delivery and its Dosimetric Implications: Any Role for Four-dimensional Set-up Verification?
Ruben JD; Seeley A; Panettieri V; Ackerly T
Clin Oncol (R Coll Radiol); 2016 Jan; 28(1):21-7. PubMed ID: 26432188
[TBL] [Abstract][Full Text] [Related]
8. Effect of abdominal compression on target movement and extension of the external boundary of peripheral lung tumours treated with stereotactic radiotherapy based on four-dimensional computed tomography.
Qi Y; Li J; Zhang Y; Shao Q; Liu X; Li F; Wang J; Li Z; Wang W
Radiat Oncol; 2021 Sep; 16(1):173. PubMed ID: 34493303
[TBL] [Abstract][Full Text] [Related]
9. Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography.
Tsai YL; Wu CJ; Shaw S; Yu PC; Nien HH; Lui LT
Radiat Oncol; 2018 Apr; 13(1):59. PubMed ID: 29609631
[TBL] [Abstract][Full Text] [Related]
10. Use of respiratory-correlated four-dimensional computed tomography to determine acceptable treatment margins for locally advanced pancreatic adenocarcinoma.
Goldstein SD; Ford EC; Duhon M; McNutt T; Wong J; Herman JM
Int J Radiat Oncol Biol Phys; 2010 Feb; 76(2):597-602. PubMed ID: 19836156
[TBL] [Abstract][Full Text] [Related]
11. Investigating the potential impact of four-dimensional computed tomography (4DCT) on toxicity, outcomes and dose escalation for radical lung cancer radiotherapy.
Cole AJ; O'Hare JM; McMahon SJ; McGarry CK; Butterworth KT; McAleese J; Jain S; Hounsell AR; Prise KM; Hanna GG; O'Sullivan JM
Clin Oncol (R Coll Radiol); 2014 Mar; 26(3):142-50. PubMed ID: 24332210
[TBL] [Abstract][Full Text] [Related]
12. Detection of interfraction displacement and volume variance during radiotherapy of primary thoracic esophageal cancer based on repeated four-dimensional CT scans.
Wang JZ; Li JB; Wang W; Qi HP; Ma ZF; Zhang YJ; Fan TY; Shao Q; Xu M
Radiat Oncol; 2013 Sep; 8():224. PubMed ID: 24074144
[TBL] [Abstract][Full Text] [Related]
13. 4-Dimensional Cone Beam Computed Tomography-Measured Target Motion Underrepresents Actual Motion.
Steiner E; Shieh CC; Caillet V; Booth J; Hardcastle N; Briggs A; Jayamanne D; Haddad C; Eade T; Keall P
Int J Radiat Oncol Biol Phys; 2018 Nov; 102(4):932-940. PubMed ID: 29907487
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of tumour motion and internal/external correlation in lung SABR.
Ali AM; Greenwood JB; Walls GM; Belshaw L; Agnew CE; McAleese J; Whitten G; Irvine DM; Hounsell AR; McGarry CK
Br J Radiol; 2023 Sep; 96(1149):20220461. PubMed ID: 37393541
[TBL] [Abstract][Full Text] [Related]
15. Implications of respiratory motion as measured by four-dimensional computed tomography for radiation treatment planning of esophageal cancer.
Patel AA; Wolfgang JA; Niemierko A; Hong TS; Yock T; Choi NC
Int J Radiat Oncol Biol Phys; 2009 May; 74(1):290-6. PubMed ID: 19362248
[TBL] [Abstract][Full Text] [Related]
16. [4D-CT-based plan target volume (PTV) definition compared with conventional PTV definition using general margin in radiotherapy for lung cancer].
Ju X; Li M; Zhou Z; Zhang K; Han W; Fu G; Cao Y; Wang L
Zhonghua Zhong Liu Za Zhi; 2014 Jan; 36(1):34-8. PubMed ID: 24685084
[TBL] [Abstract][Full Text] [Related]
17. Tumour volume comparison between 16-row multi-detector computed tomography and 320-row area-detector computed tomography in patients with small lung tumours treated with stereotactic body radiotherapy: Effect of respiratory motion.
Iizuka Y; Nakamura M; Kozawa S; Mitsuyoshi T; Matsuo Y; Mizowaki T
Eur J Radiol; 2019 Aug; 117():120-125. PubMed ID: 31307636
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of methods for selecting the midventilation bin in 4DCT scans of lung cancer patients.
Nygaard DE; Persson GF; Brink C; Specht L; Korreman SS
Acta Oncol; 2013 Nov; 52(8):1715-22. PubMed ID: 23336254
[TBL] [Abstract][Full Text] [Related]
19. Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans.
Wolthaus JW; van Herk M; Muller SH; Belderbos JS; Lebesque JV; de Bois JA; Rossi MM; Damen EM
Phys Med Biol; 2005 Apr; 50(7):1569-83. PubMed ID: 15798344
[TBL] [Abstract][Full Text] [Related]
20. Quantifying esophageal motion during free-breathing and breath-hold using fiducial markers in patients with early-stage esophageal cancer.
Doi Y; Murakami Y; Imano N; Takeuchi Y; Takahashi I; Nishibuchi I; Kimura T; Nagata Y
PLoS One; 2018; 13(6):e0198844. PubMed ID: 29889910
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]