These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 25554296)

  • 1. A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization.
    Berger AJ; Page MR; Jacob J; Young JR; Lewis J; Wenzel L; Bhallamudi VP; Johnston-Halperin E; Pelekhov DV; Hammel PC
    Rev Sci Instrum; 2014 Dec; 85(12):123702. PubMed ID: 25554296
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-resolution noncontact atomic force microscopy.
    Pérez R; García R; Schwarz U
    Nanotechnology; 2009 Jul; 20(26):260201. PubMed ID: 19531843
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Field programmable gate array based reconfigurable scanning probe/optical microscope.
    Nowak DB; Lawrence AJ; Dzegede ZK; Hiester JC; Kim C; Sánchez EJ
    Rev Sci Instrum; 2011 Oct; 82(10):103701. PubMed ID: 22047297
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Note: a 4 ns hardware photon correlator based on a general-purpose field-programmable gate array development board implemented in a compact setup for fluorescence correlation spectroscopy.
    Kalinin S; Kühnemuth R; Vardanyan H; Seidel CA
    Rev Sci Instrum; 2012 Sep; 83(9):096105. PubMed ID: 23020433
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Easily implementable field programmable gate array-based adaptive optics system with state-space multichannel control.
    Chang CY; Ke BT; Su HW; Yen WC; Chen SJ
    Rev Sci Instrum; 2013 Sep; 84(9):095112. PubMed ID: 24089871
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Functional Scanning Probe Imaging of Nanostructured Solar Energy Materials.
    Giridharagopal R; Cox PA; Ginger DS
    Acc Chem Res; 2016 Sep; 49(9):1769-76. PubMed ID: 27575611
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrical modes in scanning probe microscopy.
    Berger R; Butt HJ; Retschke MB; Weber SA
    Macromol Rapid Commun; 2009 Jul; 30(14):1167-78. PubMed ID: 21638372
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MicroFPGA: An affordable FPGA platform for microscope control.
    Deschamps J; Kieser C; Hoess P; Deguchi T; Ries J
    HardwareX; 2023 Mar; 13():e00407. PubMed ID: 36875260
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Uncovering operational mechanisms of a single-walled carbon nanotube network device using local probe electrical characterizations.
    Jeong H; Gweon HM; Kwon BJ; Ahn YH; Lee S; Park JY
    Nanotechnology; 2009 Aug; 20(34):345202. PubMed ID: 19652281
    [TBL] [Abstract][Full Text] [Related]  

  • 10. FPGA-PLC-based multi-channel position measurement system.
    Patel DM; Shah AK
    ISA Trans; 2021 Sep; 115():234-249. PubMed ID: 33455734
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Precise Nanoscale Measurements with Scanning Probe Microscopy (SPM): A Review.
    Ma Z; Zhao M; Qu Z; Gao J; Wang F; Shi Y; Qin L; Liu J
    J Nanosci Nanotechnol; 2017 Apr; 17(4):2213-234. PubMed ID: 29638104
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Note: Design of FPGA based system identification module with application to atomic force microscopy.
    Ghosal S; Pradhan S; Salapaka M
    Rev Sci Instrum; 2018 May; 89(5):056103. PubMed ID: 29864812
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultra-high vacuum scanning thermal microscopy for nanometer resolution quantitative thermometry.
    Kim K; Jeong W; Lee W; Reddy P
    ACS Nano; 2012 May; 6(5):4248-57. PubMed ID: 22530657
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Facility for low-temperature spin-polarized-scanning tunneling microscopy studies of magnetic/spintronic materials prepared in situ by nitride molecular beam epitaxy.
    Lin W; Foley A; Alam K; Wang K; Liu Y; Chen T; Pak J; Smith AR
    Rev Sci Instrum; 2014 Apr; 85(4):043702. PubMed ID: 24784613
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Digital control of force microscope cantilevers using a field programmable gate array.
    Jacky JP; Garbini JL; Ettus M; Sidles JA
    Rev Sci Instrum; 2008 Dec; 79(12):123705. PubMed ID: 19123567
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved controlled atmosphere high temperature scanning probe microscope.
    Hansen KV; Wu Y; Jacobsen T; Mogensen MB; Theil Kuhn L
    Rev Sci Instrum; 2013 Jul; 84(7):073701. PubMed ID: 23902070
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A scanning probe mounted on a field-effect transistor: Characterization of ion damage in Si.
    Shin K; Lee H; Sung M; Lee SH; Shin H; Moon W
    Micron; 2017 Oct; 101():197-205. PubMed ID: 28797948
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multichannel digital phase sensitive detection using a field programmable gate array development platform.
    Lascos SJ; Cassidy DT
    Rev Sci Instrum; 2008 Jul; 79(7):074702. PubMed ID: 18681724
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A subKelvin scanning probe microscope for the electronic spectroscopy of an individual nano-device.
    Quaglio T; Dahlem F; Martin S; Gérardin A; Winkelmann CB; Courtois H
    Rev Sci Instrum; 2012 Dec; 83(12):123702. PubMed ID: 23277991
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An ultra-compact low temperature scanning probe microscope for magnetic fields above 30 T.
    Rossi L; Gerritsen JW; Nelemans L; Khajetoorians AA; Bryant B
    Rev Sci Instrum; 2018 Nov; 89(11):113706. PubMed ID: 30501346
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.