BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1037 related articles for article (PubMed ID: 25560483)

  • 1. Impact of device landing zone calcification on paravalvular regurgitation after transcatheter aortic valve replacement: a real-time three-dimensional transesophageal echocardiographic study.
    Mihara H; Shibayama K; Berdejo J; Harada K; Itabashi Y; Siegel RJ; Kashif M; Jilaihawi H; Makkar RR; Shiota T
    J Am Soc Echocardiogr; 2015 Apr; 28(4):404-14. PubMed ID: 25560483
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Device landing zone calcification predicts significant paravalvular regurgitation after transcatheter aortic valve replacement: a real time three-dimensional transesophageal echocardiography study.
    Mihara H; Shibayama K; Harada K; Berdejo J; Itabashi Y; Makkar RR; Shiota T
    Echocardiography; 2014 May; 31(5):E142-4. PubMed ID: 25224213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
    Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
    JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Device landing zone calcification and its impact on residual regurgitation after transcatheter aortic valve implantation with different devices.
    Seiffert M; Fujita B; Avanesov M; Lunau C; Schön G; Conradi L; Prashovikj E; Scholtz S; Börgermann J; Scholtz W; Schäfer U; Lund G; Ensminger S; Treede H
    Eur Heart J Cardiovasc Imaging; 2016 May; 17(5):576-84. PubMed ID: 26160399
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of Post-Procedural Aortic Regurgitation After TAVR: An Intraprocedural TEE Study.
    Mihara H; Shibayama K; Jilaihawi H; Itabashi Y; Berdejo J; Utsunomiya H; Siegel RJ; Makkar RR; Shiota T
    JACC Cardiovasc Imaging; 2015 Sep; 8(9):993-1003. PubMed ID: 26319501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predicting paravalvular regurgitation following transcatheter valve replacement: utility of a novel method for three-dimensional echocardiographic measurements of the aortic annulus.
    Hahn RT; Khalique O; Williams MR; Koss E; Paradis JM; Daneault B; Kirtane AJ; George I; Leon MB; Kodali S
    J Am Soc Echocardiogr; 2013 Sep; 26(9):1043-52. PubMed ID: 23998695
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation.
    Hansson NC; Leipsic J; Pugliese F; Andersen HR; Rossi A; Simonato M; Jensen KT; Christiansen EH; Terkelsen CJ; Blanke P; Tang M; Krusell LR; Klaaborg KE; Terp K; Kennon S; Dvir D; Bøtker HE; Webb J; Nørgaard BL
    J Cardiovasc Comput Tomogr; 2018; 12(4):290-297. PubMed ID: 29519754
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.
    Bekeredjian R; Bodingbauer D; Hofmann NP; Greiner S; Schuetz M; Geis NA; Kauczor HU; Bryant M; Chorianopoulos E; Pleger ST; Mereles D; Katus HA; Korosoglou G
    J Invasive Cardiol; 2015 Mar; 27(3):172-80. PubMed ID: 25740972
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Methodologic Differences in Three-Dimensional Echocardiographic Measurements of the Aortic Annulus Compared with Computed Tomographic Angiography Before Transcatheter Aortic Valve Replacement.
    Khalique OK; Hamid NB; White JM; Bae DJ; Kodali SK; Nazif TM; Vahl TP; Paradis JM; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2017 Apr; 30(4):414-421. PubMed ID: 27939049
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.
    Jilaihawi H; Doctor N; Kashif M; Chakravarty T; Rafique A; Makar M; Furugen A; Nakamura M; Mirocha J; Gheorghiu M; Stegic J; Okuyama K; Sullivan DJ; Siegel R; Min JK; Gurudevan SV; Fontana GP; Cheng W; Friede G; Shiota T; Makkar RR
    J Am Coll Cardiol; 2013 Mar; 61(9):908-16. PubMed ID: 23449425
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 3D Assessment of Features Associated With Transvalvular Aortic Regurgitation After TAVR: A Real-Time 3D TEE Study.
    Shibayama K; Mihara H; Jilaihawi H; Berdejo J; Harada K; Itabashi Y; Siegel R; Makkar RR; Shiota T
    JACC Cardiovasc Imaging; 2016 Feb; 9(2):114-23. PubMed ID: 26777225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.
    Park JB; Hwang IC; Lee W; Han JK; Kim CH; Lee SP; Yang HM; Park EA; Kim HK; Chiam PTL; Kim YJ; Koo BK; Sohn DW; Ahn H; Kang JW; Park SJ; Kim HS
    Int J Cardiol; 2018 May; 259():60-68. PubMed ID: 29472027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improving the accuracy of effective orifice area assessment after transcatheter aortic valve replacement: validation of left ventricular outflow tract diameter and pulsed-wave Doppler location and impact of three-dimensional measurements.
    Khalique OK; Hamid NB; Kodali SK; Nazif TM; Marcoff L; Paradis JM; Williams MR; Vahl TP; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2015 Nov; 28(11):1283-93. PubMed ID: 26323890
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aortic valve calcification as a predictor of location and severity of paravalvular regurgitation after transcatheter aortic valve implantation.
    Koh EY; Lam KY; Bindraban NR; Cocchieri R; Planken RN; Koch KT; Baan J; de Mol BA; Marquering HA
    Interact Cardiovasc Thorac Surg; 2015 Mar; 20(3):345-50. PubMed ID: 25487234
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation.
    Gripari P; Ewe SH; Fusini L; Muratori M; Ng AC; Cefalù C; Delgado V; Schalij MJ; Bax JJ; Marsan NA; Tamborini G; Pepi M
    Heart; 2012 Aug; 98(16):1229-36. PubMed ID: 22826560
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.
    Jilaihawi H; Makkar RR; Kashif M; Okuyama K; Chakravarty T; Shiota T; Friede G; Nakamura M; Doctor N; Rafique A; Shibayama K; Mihara H; Trento A; Cheng W; Friedman J; Berman D; Fontana GP
    Eur Heart J Cardiovasc Imaging; 2014 Dec; 15(12):1324-32. PubMed ID: 25187618
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of transcatheter aortic valve replacement on the mitral valve apparatus and mitral regurgitation: real-time three-dimensional transesophageal echocardiography study.
    Shibayama K; Harada K; Berdejo J; Mihara H; Tanaka J; Gurudevan SV; Siegel R; Jilaihawi H; Makkar RR; Shiota T
    Circ Cardiovasc Imaging; 2014 Mar; 7(2):344-51. PubMed ID: 24474596
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Management of paravalvular regurgitation after Edwards SAPIEN transcatheter aortic valve replacement: management of paravalvular regurgitation after TAVR.
    Martinez CA; Singh V; O'Neill BP; Alfonso CE; Bilsker MS; Martinez Clark P; Williams D; Cohen MG; Heldman AW; O'Neill WW
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):300-11. PubMed ID: 23580318
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 52.