These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 25570041)

  • 21. Design of ultra-low power biopotential amplifiers for biosignal acquisition applications.
    Zhang F; Holleman J; Otis BP
    IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):344-55. PubMed ID: 23853179
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A Low Power Low Phase Noise Oscillator for MICS Transceivers.
    Li D; Liu D; Kang C; Zou X
    Sensors (Basel); 2017 Jan; 17(1):. PubMed ID: 28085107
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A high frequency active voltage doubler in standard CMOS using offset-controlled comparators for inductive power transmission.
    Lee HM; Ghovanloo M
    IEEE Trans Biomed Circuits Syst; 2013 Jun; 7(3):213-24. PubMed ID: 23853321
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A CMOS power-efficient low-noise current-mode front-end amplifier for neural signal recording.
    Wu CY; Chen WM; Kuo LT
    IEEE Trans Biomed Circuits Syst; 2013 Apr; 7(2):107-14. PubMed ID: 23853293
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A 200-Mb/s Energy Efficient Transcranial Transmitter Using Inductive Coupling.
    Li W; Duan Y; Rabaey J
    IEEE Trans Biomed Circuits Syst; 2019 Apr; 13(2):435-443. PubMed ID: 30596584
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Analysis and Design of Integrated Blocks for a 6.25 GHz Spacefibre PLL.
    Mestice M; Neri B; Ciarpi G; Saponara S
    Sensors (Basel); 2020 Jul; 20(14):. PubMed ID: 32707677
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A 400 MHz Wireless Neural Signal Processing IC With 625 $\times$ On-Chip Data Reduction and Reconfigurable BFSK/QPSK Transmitter Based on Sequential Injection Locking.
    Teng KH; Wu T; Liu X; Yang Z; Heng CH
    IEEE Trans Biomed Circuits Syst; 2017 Jun; 11(3):547-557. PubMed ID: 28278483
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Design of a Low Noise Bio-Potential Recorder With High Tolerance to Power-Line Interference Under 0.8 V Power Supply.
    Luo D; Lei J; Zhang M; Wang Z
    IEEE Trans Biomed Circuits Syst; 2020 Dec; 14(6):1421-1430. PubMed ID: 33201829
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A 7/24-GHz CMOS VCO with High Band Ratio Using a Current-Source Switching Topology.
    Wang S; Xiao CY
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 May; 63(5):790-795. PubMed ID: 26955028
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Design and Implementation of Charge Pump Phase-Locked Loop Frequency Source Based on GaAs pHEMT Process.
    Zhao R; Zhang Y; Lv H; Wu Y
    Sensors (Basel); 2022 Jan; 22(2):. PubMed ID: 35062464
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Chip Design of an All-Digital Frequency Synthesizer with Reference Spur Reduction Technique for Radar Sensing.
    Lai WC
    Sensors (Basel); 2022 Mar; 22(7):. PubMed ID: 35408185
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A Low-Power All-Digital on-Chip CMOS Oscillator for a Wireless Sensor Node.
    Sheng D; Hong MR
    Sensors (Basel); 2016 Oct; 16(10):. PubMed ID: 27754439
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A wireless power interface for rechargeable battery operated neural recording implants.
    Li P; Principe JC; Bashirullah R
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6253-6. PubMed ID: 17946366
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clock recovery PLL with gated PFD for NRZ ON-OFF Modulated Signals in a retinal implant system.
    Brendler C; Aryan NP; Rieger V; Rothermel A
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():5497-500. PubMed ID: 24110981
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A low-phase-noise Ka-band push-push voltage-controlled oscillator using CMOS/glass-integrated passive device technologies.
    Wang S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Sep; 61(9):1456-62. PubMed ID: 25167145
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A Reference-Sampling Based Calibration-Free Fractional-N PLL with a PI-Linked Sampling Clock Generator.
    Han JS; Eom TH; Choi SW; Seong K; Yoon DH; Kim TT; Baek KH; Shim Y
    Sensors (Basel); 2021 Oct; 21(20):. PubMed ID: 34696037
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Automatic frequency controller for power amplifiers used in bio-implanted applications: issues and challenges.
    Hannan MA; Hussein HA; Mutashar S; Samad SA; Hussain A
    Sensors (Basel); 2014 Dec; 14(12):23843-70. PubMed ID: 25615728
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A 2.4 GHz ULP reconfigurable asymmetric transceiver for single-chip wireless neural recording IC.
    Tan J; Liew WS; Heng CH; Lian Y
    IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):497-509. PubMed ID: 25073126
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A CMOS RF Receiver with Improved Resilience to OFDM-Induced Second-Order Intermodulation Distortion for MedRadio Biomedical Devices and Sensors.
    Lee Y; Chang S; Kim J; Shin H
    Sensors (Basel); 2021 Aug; 21(16):. PubMed ID: 34450744
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A 0.8 V, 5.3-5.9 GHz Sub-Sampling PLL with 196.5 fs
    Zuo S; Zhao J; Zhou Y
    Sensors (Basel); 2021 Nov; 21(22):. PubMed ID: 34833724
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.