These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 25570739)

  • 21. An acetone bio-sniffer (gas phase biosensor) enabling assessment of lipid metabolism from exhaled breath.
    Ye M; Chien PJ; Toma K; Arakawa T; Mitsubayashi K
    Biosens Bioelectron; 2015 Nov; 73():208-213. PubMed ID: 26079672
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An Acetone Sensor Based on Plasma-Assisted Cataluminescence and Mechanism Studies by Online Ionizations.
    Zeng N; Long Z; Wang Y; Sun J; Ouyang J; Na N
    Anal Chem; 2019 Dec; 91(24):15763-15768. PubMed ID: 31722526
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Supervised Bayesian Source Separation of Nonlinear Mixtures for Quantitative Analysis of Gas Mixtures.
    Madrolle S; Duarte LT; Grangeat P; Jutten C
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():1230-1233. PubMed ID: 30440612
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Experimental setup and analytical methods for the non-invasive determination of volatile organic compounds, formaldehyde and NOx in exhaled human breath.
    Riess U; Tegtbur U; Fauck C; Fuhrmann F; Markewitz D; Salthammer T
    Anal Chim Acta; 2010 Jun; 669(1-2):53-62. PubMed ID: 20510903
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Characterization and evolution of exposure to volatile organic compounds in the Spanish shoemaking industry over a 5-year period.
    Estevan C; Ferri F; Sogorb MA; Vilanova E
    J Occup Environ Hyg; 2012; 9(11):653-62. PubMed ID: 23016600
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hybrid Analytical Platform Based on Field-Asymmetric Ion Mobility Spectrometry, Infrared Sensing, and Luminescence-Based Oxygen Sensing for Exhaled Breath Analysis.
    Hagemann LT; Repp S; Mizaikoff B
    Sensors (Basel); 2019 Jun; 19(12):. PubMed ID: 31212768
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Validation of an analytical method for quality control of residual solvents (n-hexane and acetone) in D-002: new active ingredient from beeswax.
    Antolín EM; Quiñónez YB; Canavaciolo VG; Cruz ER
    J Pharm Biomed Anal; 2008 Jul; 47(3):646-50. PubMed ID: 18462903
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High-Pressure Photon Ionization Source for TOFMS and Its Application for Online Breath Analysis.
    Wang Y; Jiang J; Hua L; Hou K; Xie Y; Chen P; Liu W; Li Q; Wang S; Li H
    Anal Chem; 2016 Sep; 88(18):9047-55. PubMed ID: 27574033
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Measurement of volatile organic compounds in exhaled breath as collected in evacuated electropolished canisters.
    Pleil JD; Lindstrom AB
    J Chromatogr B Biomed Appl; 1995 Mar; 665(2):271-9. PubMed ID: 7795807
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis.
    Smith D; Spanel P
    Mass Spectrom Rev; 2005; 24(5):661-700. PubMed ID: 15495143
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A membrane bioreactor for the simultaneous treatment of acetone, toluene, limonene and hexane at trace level concentrations.
    Lebrero R; Volckaert D; Pérez R; Muñoz R; Van Langenhove H
    Water Res; 2013 May; 47(7):2199-212. PubMed ID: 23497859
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Breath ethanol and acetone as indicators of serum glucose levels: an initial report.
    Galassetti PR; Novak B; Nemet D; Rose-Gottron C; Cooper DM; Meinardi S; Newcomb R; Zaldivar F; Blake DR
    Diabetes Technol Ther; 2005 Feb; 7(1):115-23. PubMed ID: 15738709
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A sub-ppm acetone gas sensor for diabetes detection using 10 nm thick ultrathin InN FETs.
    Kao KW; Hsu MC; Chang YH; Gwo S; Yeh JA
    Sensors (Basel); 2012; 12(6):7157-68. PubMed ID: 22969342
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Design of efficient zeolite sensor materials for n-hexane.
    Yang P; Ye X; Lau C; Li Z; Liu X; Lu J
    Anal Chem; 2007 Feb; 79(4):1425-32. PubMed ID: 17297941
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Novel Self-Assembly Route Assisted Ultra-Fast Trace Volatile Organic Compounds Gas Sensing Based on Three-Dimensional Opal Microspheres Composites for Diabetes Diagnosis.
    Wang T; Zhang S; Yu Q; Wang S; Sun P; Lu H; Liu F; Yan X; Lu G
    ACS Appl Mater Interfaces; 2018 Sep; 10(38):32913-32921. PubMed ID: 30176721
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Water-Resistant Polymeric Acid Membrane Catalyst for Acetone Detection in the Exhaled Breath of Diabetics.
    Worrall AD; Qian Z; Bernstein JA; Angelopoulos AP
    Anal Chem; 2018 Feb; 90(3):1819-1826. PubMed ID: 29280625
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Application of membrane extraction with sorbent interface for breath analysis.
    Ma V; Lord H; Morley M; Pawliszyn J
    Methods Mol Biol; 2010; 610():451-68. PubMed ID: 20013195
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath.
    Spanĕl P; Smith D
    Med Biol Eng Comput; 1996 Nov; 34(6):409-19. PubMed ID: 9039741
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fiber-enhanced Raman multigas spectroscopy: a versatile tool for environmental gas sensing and breath analysis.
    Hanf S; Keiner R; Yan D; Popp J; Frosch T
    Anal Chem; 2014 Jun; 86(11):5278-85. PubMed ID: 24846710
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Sorption kinetics of selected volatile organic compounds in humin.
    Shih YH; Wu SC
    Environ Toxicol Chem; 2002 Oct; 21(10):2067-74. PubMed ID: 12371482
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.