These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 25571459)
1. Comparison of a priori calibration models for respiratory inductance plethysmography during running. Leutheuser H; Heyde C; Gollhofer A; Eskofier BM Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6393-6. PubMed ID: 25571459 [TBL] [Abstract][Full Text] [Related]
2. Reference-Free Adjustment of Respiratory Inductance Plethysmography for Measurements during Physical Exercise. Leutheuser H; Heyde C; Roecker K; Gollhofer A; Eskofier BM IEEE Trans Biomed Eng; 2017 Dec; 64(12):2836-2846. PubMed ID: 28278451 [TBL] [Abstract][Full Text] [Related]
3. Respiratory inductance plethysmography-a rationale for validity during exercise. Heyde C; Leutheuser H; Eskofier B; Roecker K; Gollhofer A Med Sci Sports Exerc; 2014 Mar; 46(3):488-95. PubMed ID: 24042313 [TBL] [Abstract][Full Text] [Related]
4. Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography. Lo WLA; Huang DF J Clin Monit Comput; 2017 Aug; 31(4):755-764. PubMed ID: 27289525 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of various models for respiratory inductance plethysmography calibration. Strömberg NO; Dahlbäck GO; Gustafsson PM J Appl Physiol (1985); 1993 Mar; 74(3):1206-11. PubMed ID: 8482659 [TBL] [Abstract][Full Text] [Related]
6. Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions. Emeriaud G; Eberhard A; Benchetrit G; Debillon T; Baconnier P Pediatr Pulmonol; 2008 Nov; 43(11):1135-1141. PubMed ID: 18846561 [TBL] [Abstract][Full Text] [Related]
7. Validation of respiratory inductive plethysmography in patients with pulmonary disease. Tobin MJ; Jenouri G; Lind B; Watson H; Schneider A; Sackner MA Chest; 1983 Apr; 83(4):615-20. PubMed ID: 6831949 [TBL] [Abstract][Full Text] [Related]
8. Inductive plethysmography potential as a surrogate for ventilatory measurements during rest and moderate physical exercise. Cabiddu R; Pantoni CB; Mendes RG; Trimer R; Catai AM; Borghi-Silva A Braz J Phys Ther; 2016 Mar; 20(2):184-8. PubMed ID: 26982454 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of respiratory inductive plethysmography in infants weighing less than 1,500 grams. Wilkes DL; Revow M; Bryan MH; England SJ Am Rev Respir Dis; 1987 Aug; 136(2):416-9. PubMed ID: 3619201 [TBL] [Abstract][Full Text] [Related]
10. Respiratory inductance plethysmography calibration for pediatric upper airway obstruction: an animal model. Khemani RG; Flink R; Hotz J; Ross PA; Ghuman A; Newth CJ Pediatr Res; 2015 Jan; 77(1-1):75-83. PubMed ID: 25279987 [TBL] [Abstract][Full Text] [Related]
11. Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs. Warren RH; Fewell JE; Alderson SH Chest; 1988 Aug; 94(2):325-8. PubMed ID: 3396411 [TBL] [Abstract][Full Text] [Related]
12. Measurement of exercise ventilation by a portable respiratory inductive plethysmograph. Witt JD; Fisher JR; Guenette JA; Cheong KA; Wilson BJ; Sheel AW Respir Physiol Neurobiol; 2006 Dec; 154(3):389-95. PubMed ID: 16503424 [TBL] [Abstract][Full Text] [Related]
13. Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture. Stradling JR; Chadwick GA; Quirk C; Phillips T Bull Eur Physiopathol Respir; 1985; 21(4):317-24. PubMed ID: 4041657 [TBL] [Abstract][Full Text] [Related]
14. A wearable respiratory monitoring device--the between-days variability of calibration. Heyde C; Mahler H; Roecker K; Gollhofer A Int J Sports Med; 2015 Jan; 36(1):29-34. PubMed ID: 25254900 [TBL] [Abstract][Full Text] [Related]
15. Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph. Zimmerman PV; Connellan SJ; Middleton HC; Tabona MV; Goldman MD; Pride N Am Rev Respir Dis; 1983 Feb; 127(2):209-14. PubMed ID: 6830037 [TBL] [Abstract][Full Text] [Related]
16. Calibration of respiratory inductive plethysmography in lambs receiving intermittent mandatory mechanical ventilation. Warren RH; Alderson SH Crit Care Med; 1988 Feb; 16(2):161-4. PubMed ID: 3277774 [TBL] [Abstract][Full Text] [Related]
17. Validation of respiratory inductive plethysmography using different calibration procedures. Chadha TS; Watson H; Birch S; Jenouri GA; Schneider AW; Cohn MA; Sackner MA Am Rev Respir Dis; 1982 Jun; 125(6):644-9. PubMed ID: 7091869 [TBL] [Abstract][Full Text] [Related]
18. Error analysis of a natural breathing calibration method for respiratory inductive plethysmography. Strömberg NO Med Biol Eng Comput; 2001 May; 39(3):310-4. PubMed ID: 11465885 [TBL] [Abstract][Full Text] [Related]
19. Calibration of respiratory inductive plethysmograph during natural breathing. Sackner MA; Watson H; Belsito AS; Feinerman D; Suarez M; Gonzalez G; Bizousky F; Krieger B J Appl Physiol (1985); 1989 Jan; 66(1):410-20. PubMed ID: 2917945 [TBL] [Abstract][Full Text] [Related]