These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 25581739)

  • 1. Effect of angular stability and other locking parameters on the mechanical performance of intramedullary nails.
    Hoffmann S; Gerber C; von Oldenburg G; Kessler M; Stephan D; Augat P
    Biomed Tech (Berl); 2015 Apr; 60(2):157-64. PubMed ID: 25581739
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Intramedullary nailing of the distal tibia. Does angular stable locking make a difference?].
    Augat P; Bühren V
    Unfallchirurg; 2015 Apr; 118(4):311-7. PubMed ID: 25835206
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
    Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
    J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Angle-stable fixation of intramedullary nails using the Angular Stable Locking System® (ASLS)].
    Höntzsch D; Blauth M; Attal R
    Oper Orthop Traumatol; 2011 Dec; 23(5):387-96. PubMed ID: 22270968
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical study of the safe distance between distal femoral fracture site and distal locking screws in antegrade intramedullary nailing.
    Antekeier SB; Burden RL; Voor MJ; Roberts CS
    J Orthop Trauma; 2005; 19(10):693-7. PubMed ID: 16314716
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing.
    Chan DS; Nayak AN; Blaisdell G; James CR; Denard A; Miles J; Santoni BG
    J Orthop Trauma; 2015 Feb; 29(2):98-104. PubMed ID: 25072288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Internal fixation of type-C distal femoral fractures in osteoporotic bone: surgical technique.
    Mückley T; Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO
    J Bone Joint Surg Am; 2011 Mar; 93 Suppl 1():40-53. PubMed ID: 21411685
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures: A cadaver-based laboratory investigation.
    Pekmezci M; McDonald E; Buckley J; Kandemir U
    Bone Joint J; 2014 Jan; 96-B(1):114-21. PubMed ID: 24395321
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model.
    Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M
    Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study.
    Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N
    J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
    Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
    Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the effectiveness of the angular stable locking system in patients with distal tibial fractures treated with intramedullary nailing: a multicenter randomized controlled trial.
    Höntzsch D; Schaser KD; Hofmann GO; Pohlemann T; Hem ES; Rothenbach E; Krettek C; Attal R
    J Bone Joint Surg Am; 2014 Nov; 96(22):1889-97. PubMed ID: 25410507
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term stability of angle-stable versus conventional locked intramedullary nails in distal tibia fractures.
    Wähnert D; Stolarczyk Y; Hoffmeier KL; Raschke MJ; Hofmann GO; Mückley T
    BMC Musculoskelet Disord; 2013 Feb; 14():66. PubMed ID: 23425016
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Distal Locking Screws for Intramedullary Nailing of Tibial Fractures.
    Agathangelidis F; Petsatodis G; Kirkos J; Papadopoulos P; Karataglis D; Christodoulou A
    Orthopedics; 2016; 39(2):e253-8. PubMed ID: 26840700
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fatigue performance of angle-stable tibial nail interlocking screws.
    Lenz M; Gueorguiev B; Richards RG; Mückley T; Hofmann GO; Höntzsch D; Windolf M
    Int Orthop; 2013 Jan; 37(1):113-8. PubMed ID: 22875484
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails.
    Erden T; Kapicioglu M; Demirtas A; Bilsel K; Akpinar F; Kuduz H
    Acta Orthop Traumatol Turc; 2019 Nov; 53(6):490-496. PubMed ID: 31562026
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The primary stability of angle-stable versus conventional locked intramedullary nails.
    Wähnert D; Stolarczyk Y; Hoffmeier KL; Raschke MJ; Hofmann GO; Mückley T
    Int Orthop; 2012 May; 36(5):1059-64. PubMed ID: 22127384
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.