  • 41. [Non-functional lead as a cause of detection disturbances in implantable cardioverter-defibrillator].
    Kempa M; Budrejko S; Nowakowski M; Królak T; Daniłowicz-Szymanowicz L; Raczak G
    Kardiol Pol; 2012; 70(10):1073-5. PubMed ID: 23080104
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Defibrillation testing can reveal 'concealed' lead fracture.
    Bun SS; Duytschaever M; Tavernier R
    Europace; 2013 Jan; 15(1):54. PubMed ID: 22719061
    [No Abstract]   [Full Text] [Related]  

  • 43. Late complications of electrotherapy - a clinical analysis of indications for transvenous removal of endocardial leads: a single centre experience.
    Polewczyk A; Kutarski A; Tomaszewski A; Polewczyk M; Janion M
    Kardiol Pol; 2013; 71(4):366-72. PubMed ID: 23788342
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Paradoxical thromboembolic stroke during extraction of a recalled St Jude Medical Riata defibrillator lead with conductor externalization.
    Larsen JM; Theuns DA; Thøgersen AM
    Europace; 2014 Feb; 16(2):240. PubMed ID: 23933851
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.
    Alam MB; Munir MB; Rattan R; Flanigan S; Adelstein E; Jain S; Saba S
    Europace; 2014 Feb; 16(2):246-51. PubMed ID: 24099864
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Early Durata lead failure caused by rib-clavicular crush.
    Ahmed FZ; Allen S; Mamas M; Zaidi AM
    Can J Cardiol; 2014 Oct; 30(10):1249.e17-8. PubMed ID: 25154804
    [TBL] [Abstract][Full Text] [Related]  

  • 47. An ICD lead with failure of outer insulation goes undetected by regular measurements.
    Chan CW; Chiang CS
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):e261-2. PubMed ID: 21745226
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Conductor externalization in a Riata ST Optim™ lead.
    Deeprasertkul P; Yunus A; Thakur R
    Europace; 2013 Jul; 15(7):1012. PubMed ID: 23419661
    [No Abstract]   [Full Text] [Related]  

  • 49. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.
    Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K
    Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Improvement in hemodynamic response using a quadripolar LV lead.
    Cabrera Bueno F; Alzueta Rodríguez J; Olagüe de Ros J; Fernández-Lozano I; García Guerrero JJ; de la Concha JF; Hernández Madrid A; Tolosana Viu JM; Osca Asensi J; Barrera Cordero A; Llorente Hernangómez E
    Pacing Clin Electrophysiol; 2013 Aug; 36(8):963-9. PubMed ID: 23692289
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Transvenous implantable cardioverter-defibrillator leads: the weakest link.
    Maisel WH
    Circulation; 2007 May; 115(19):2461-3. PubMed ID: 17502585
    [No Abstract]   [Full Text] [Related]  

  • 52. Mortality risk of Fidelis management.
    Faddis MN
    J Am Coll Cardiol; 2011 Jul; 58(3):284-5. PubMed ID: 21737020
    [No Abstract]   [Full Text] [Related]  

  • 53. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers.
    Chung EH; Casavant D; John RM
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee.
    Theuns DA; Elvan A; de Voogt W; de Cock CC; van Erven L; Meine M
    Circ Arrhythm Electrophysiol; 2012 Dec; 5(6):1059-63. PubMed ID: 23091049
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A fatal complication of ICD therapy due to lead failure.
    Theuns DA; Szili-Torok T; Jordaens LJ
    J Cardiovasc Electrophysiol; 2008 Jul; 19(7):E48. PubMed ID: 18554196
    [No Abstract]   [Full Text] [Related]  

  • 56. Clinical performance of the St. Jude Medical Riata defibrillation lead in a large patient population.
    Porterfield JG; Porterfield LM; Kuck KH; Corbisiero R; Greenberg SM; Hindricks G; Wazni O; Beau SL; Herre JM
    J Cardiovasc Electrophysiol; 2010 May; 21(5):551-6. PubMed ID: 19925609
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Lead system causing twiddler's syndrome in patients with an implantable cardioverter-defibrillator.
    Bracke F; van Gelder B; Dijkman B; Meijer A
    J Thorac Cardiovasc Surg; 2005 Jan; 129(1):231-2. PubMed ID: 15632856
    [No Abstract]   [Full Text] [Related]  

  • 59. Lead fracture and free-wall perforation in a patient with an implantable cardioverter-defibrillator.
    Kwon O; Kang SH; Park HW; Choi SW; Kim SH; Kim KH; Jin ES; Nam GB
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e167-9. PubMed ID: 21070262
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Electrocautery-induced ventricular fibrillation during routine implantable cardioverter-defibrillator generator replacement.
    Cassagneau R; Hanninen M; Yee R
    Europace; 2014 Mar; 16(3):319. PubMed ID: 24068449
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.