These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 25582957)
41. [Non-functional lead as a cause of detection disturbances in implantable cardioverter-defibrillator]. Kempa M; Budrejko S; Nowakowski M; Królak T; Daniłowicz-Szymanowicz L; Raczak G Kardiol Pol; 2012; 70(10):1073-5. PubMed ID: 23080104 [TBL] [Abstract][Full Text] [Related]
42. Defibrillation testing can reveal 'concealed' lead fracture. Bun SS; Duytschaever M; Tavernier R Europace; 2013 Jan; 15(1):54. PubMed ID: 22719061 [No Abstract] [Full Text] [Related]
43. Late complications of electrotherapy - a clinical analysis of indications for transvenous removal of endocardial leads: a single centre experience. Polewczyk A; Kutarski A; Tomaszewski A; Polewczyk M; Janion M Kardiol Pol; 2013; 71(4):366-72. PubMed ID: 23788342 [TBL] [Abstract][Full Text] [Related]
44. Paradoxical thromboembolic stroke during extraction of a recalled St Jude Medical Riata defibrillator lead with conductor externalization. Larsen JM; Theuns DA; Thøgersen AM Europace; 2014 Feb; 16(2):240. PubMed ID: 23933851 [TBL] [Abstract][Full Text] [Related]
45. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators. Alam MB; Munir MB; Rattan R; Flanigan S; Adelstein E; Jain S; Saba S Europace; 2014 Feb; 16(2):246-51. PubMed ID: 24099864 [TBL] [Abstract][Full Text] [Related]
46. Early Durata lead failure caused by rib-clavicular crush. Ahmed FZ; Allen S; Mamas M; Zaidi AM Can J Cardiol; 2014 Oct; 30(10):1249.e17-8. PubMed ID: 25154804 [TBL] [Abstract][Full Text] [Related]
47. An ICD lead with failure of outer insulation goes undetected by regular measurements. Chan CW; Chiang CS Pacing Clin Electrophysiol; 2012 Sep; 35(9):e261-2. PubMed ID: 21745226 [TBL] [Abstract][Full Text] [Related]
48. Conductor externalization in a Riata ST Optim™ lead. Deeprasertkul P; Yunus A; Thakur R Europace; 2013 Jul; 15(7):1012. PubMed ID: 23419661 [No Abstract] [Full Text] [Related]
49. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696 [TBL] [Abstract][Full Text] [Related]
50. Improvement in hemodynamic response using a quadripolar LV lead. Cabrera Bueno F; Alzueta Rodríguez J; Olagüe de Ros J; Fernández-Lozano I; García Guerrero JJ; de la Concha JF; Hernández Madrid A; Tolosana Viu JM; Osca Asensi J; Barrera Cordero A; Llorente Hernangómez E Pacing Clin Electrophysiol; 2013 Aug; 36(8):963-9. PubMed ID: 23692289 [TBL] [Abstract][Full Text] [Related]
53. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers. Chung EH; Casavant D; John RM Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868 [TBL] [Abstract][Full Text] [Related]
54. Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee. Theuns DA; Elvan A; de Voogt W; de Cock CC; van Erven L; Meine M Circ Arrhythm Electrophysiol; 2012 Dec; 5(6):1059-63. PubMed ID: 23091049 [TBL] [Abstract][Full Text] [Related]
55. A fatal complication of ICD therapy due to lead failure. Theuns DA; Szili-Torok T; Jordaens LJ J Cardiovasc Electrophysiol; 2008 Jul; 19(7):E48. PubMed ID: 18554196 [No Abstract] [Full Text] [Related]
56. Clinical performance of the St. Jude Medical Riata defibrillation lead in a large patient population. Porterfield JG; Porterfield LM; Kuck KH; Corbisiero R; Greenberg SM; Hindricks G; Wazni O; Beau SL; Herre JM J Cardiovasc Electrophysiol; 2010 May; 21(5):551-6. PubMed ID: 19925609 [TBL] [Abstract][Full Text] [Related]
57. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
58. Lead system causing twiddler's syndrome in patients with an implantable cardioverter-defibrillator. Bracke F; van Gelder B; Dijkman B; Meijer A J Thorac Cardiovasc Surg; 2005 Jan; 129(1):231-2. PubMed ID: 15632856 [No Abstract] [Full Text] [Related]
59. Lead fracture and free-wall perforation in a patient with an implantable cardioverter-defibrillator. Kwon O; Kang SH; Park HW; Choi SW; Kim SH; Kim KH; Jin ES; Nam GB Pacing Clin Electrophysiol; 2012 Jun; 35(6):e167-9. PubMed ID: 21070262 [TBL] [Abstract][Full Text] [Related]