These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
439 related articles for article (PubMed ID: 25585030)
1. Scoring of coronary artery calcium scans: history, assumptions, current limitations, and future directions. Alluri K; Joshi PH; Henry TS; Blumenthal RS; Nasir K; Blaha MJ Atherosclerosis; 2015 Mar; 239(1):109-17. PubMed ID: 25585030 [TBL] [Abstract][Full Text] [Related]
2. Improving the relationship between coronary artery calcium score and coronary plaque burden: addition of regional measures of coronary artery calcium distribution. Tota-Maharaj R; Al-Mallah MH; Nasir K; Qureshi WT; Blumenthal RS; Blaha MJ Atherosclerosis; 2015 Jan; 238(1):126-31. PubMed ID: 25479801 [TBL] [Abstract][Full Text] [Related]
3. Estimation of cardiovascular risk on routine chest CT: Ordinal coronary artery calcium scoring as an accurate predictor of Agatston score ranges. Azour L; Kadoch MA; Ward TJ; Eber CD; Jacobi AH J Cardiovasc Comput Tomogr; 2017; 11(1):8-15. PubMed ID: 27743881 [TBL] [Abstract][Full Text] [Related]
4. Impact of Hybrid Iterative Reconstruction on Agatston Coronary Artery Calcium Scores in Comparison to Filtered Back Projection in Native Cardiac CT. Obmann VC; Klink T; Heverhagen JT; Stork A; Laqmani A; Adam G; Begemann PG Rofo; 2015 May; 187(5):372-9. PubMed ID: 25962672 [TBL] [Abstract][Full Text] [Related]
5. Calcium score of small coronary calcifications on multidetector computed tomography: results from a static phantom study. Groen JM; Kofoed KF; Zacho M; Vliegenthart R; Willems TP; Greuter MJ Eur J Radiol; 2013 Feb; 82(2):e58-63. PubMed ID: 23092538 [TBL] [Abstract][Full Text] [Related]
6. Controversies about effects of low-kilovoltage MDCT acquisition on Agatston calcium scoring. Deprez FC; Vlassenbroek A; Ghaye B; Raaijmakers R; Coche E J Cardiovasc Comput Tomogr; 2013; 7(1):58-61. PubMed ID: 23333185 [TBL] [Abstract][Full Text] [Related]
7. Feasibility of coronary artery calcium scoring on virtual unenhanced images derived from single-source fast kVp-switching dual-energy coronary CT angiography. Yamada Y; Jinzaki M; Okamura T; Yamada M; Tanami Y; Abe T; Kuribayashi S J Cardiovasc Comput Tomogr; 2014; 8(5):391-400. PubMed ID: 25301045 [TBL] [Abstract][Full Text] [Related]
8. Thoracic aortic calcium versus coronary artery calcium for the prediction of coronary heart disease and cardiovascular disease events. Wong ND; Gransar H; Shaw L; Polk D; Moon JH; Miranda-Peats R; Hayes SW; Thomson LE; Rozanski A; Friedman JD; Berman DS JACC Cardiovasc Imaging; 2009 Mar; 2(3):319-26. PubMed ID: 19356578 [TBL] [Abstract][Full Text] [Related]
9. Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5-mm slice thickness using iterative reconstruction. Hou KY; Tsujioka K; Yang CC J Appl Clin Med Phys; 2020 Feb; 21(2):111-120. PubMed ID: 31889419 [TBL] [Abstract][Full Text] [Related]
10. Coronary Artery Calcium Scoring: Is It Time for a Change in Methodology? Blaha MJ; Mortensen MB; Kianoush S; Tota-Maharaj R; Cainzos-Achirica M JACC Cardiovasc Imaging; 2017 Aug; 10(8):923-937. PubMed ID: 28797416 [TBL] [Abstract][Full Text] [Related]
11. Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT. Horiguchi J; Yamamoto H; Hirai N; Akiyama Y; Fujioka C; Marukawa K; Fukuda H; Ito K AJR Am J Roentgenol; 2006 Jul; 187(1):W1-6. PubMed ID: 16794121 [TBL] [Abstract][Full Text] [Related]
12. Very low-dose coronary artery calcium scanning with high-pitch spiral acquisition mode: comparison between 120-kV and 100-kV tube voltage protocols. Marwan M; Mettin C; Pflederer T; Seltmann M; Schuhbäck A; Muschiol G; Ropers D; Daniel WG; Achenbach S J Cardiovasc Comput Tomogr; 2013; 7(1):32-8. PubMed ID: 23333186 [TBL] [Abstract][Full Text] [Related]
13. Cardiac Society of Australia and New Zealand Position Statement: Coronary Artery Calcium Scoring. Liew G; Chow C; van Pelt N; Younger J; Jelinek M; Chan J; Hamilton-Craig C Heart Lung Circ; 2017 Dec; 26(12):1239-1251. PubMed ID: 28690020 [TBL] [Abstract][Full Text] [Related]
14. [Coronary artery calcium identified by multislice TC as marker of early coronary artery disease]. Iori E; Bendinelli S; Faggiano P Monaldi Arch Chest Dis; 2003 Mar; 60(1):63-72. PubMed ID: 12827835 [TBL] [Abstract][Full Text] [Related]
15. Assessment of isotropic calcium using 0.5-mm reconstructions from 320-row CT data sets identifies more patients with non-zero Agatston score and more subclinical atherosclerosis than standard 3.0-mm coronary artery calcium scan and CT angiography. Aslam A; Khokhar US; Chaudhry A; Abramowicz A; Rajper N; Cortegiano M; Poon M; Voros S J Cardiovasc Comput Tomogr; 2014; 8(1):58-66. PubMed ID: 24582044 [TBL] [Abstract][Full Text] [Related]
16. Coronary artery calcium scoring does not add prognostic value to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease. Kwon SW; Kim YJ; Shim J; Sung JM; Han ME; Kang DW; Kim JY; Choi BW; Chang HJ Radiology; 2011 Apr; 259(1):92-9. PubMed ID: 21324842 [TBL] [Abstract][Full Text] [Related]
17. Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort--consequences for progression studies. Hoffmann U; Siebert U; Bull-Stewart A; Achenbach S; Ferencik M; Moselewski F; Brady TJ; Massaro JM; O'Donnell CJ Eur J Radiol; 2006 Mar; 57(3):396-402. PubMed ID: 16434160 [TBL] [Abstract][Full Text] [Related]