These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods. Mitsuyoshi T; Nakamura M; Matsuo Y; Ueki N; Nakamura A; Iizuka Y; Mampuya WA; Mizowaki T; Hiraoka M Med Dosim; 2016 Winter; 41(4):305-309. PubMed ID: 27623737 [TBL] [Abstract][Full Text] [Related]
3. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans. Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883 [TBL] [Abstract][Full Text] [Related]
4. Difference in dose-volumetric data between the analytical anisotropic algorithm, the dose-to-medium, and the dose-to-water reporting modes of the Acuros XB for lung stereotactic body radiation therapy. Mampuya WA; Nakamura M; Hirose Y; Kitsuda K; Ishigaki T; Mizowaki T; Hiraoka M J Appl Clin Med Phys; 2016 Sep; 17(5):341-347. PubMed ID: 27685138 [TBL] [Abstract][Full Text] [Related]
5. Verification of planning target volume settings in volumetric modulated arc therapy for stereotactic body radiation therapy by using in-treatment 4-dimensional cone beam computed tomography. Takahashi W; Yamashita H; Kida S; Masutani Y; Sakumi A; Ohtomo K; Nakagawa K; Haga A Int J Radiat Oncol Biol Phys; 2013 Jul; 86(3):426-31. PubMed ID: 23562767 [TBL] [Abstract][Full Text] [Related]
6. Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal metastases. Zhen H; Hrycushko B; Lee H; Timmerman R; Pompoš A; Stojadinovic S; Foster R; Jiang SB; Solberg T; Gu X J Appl Clin Med Phys; 2015 Jul; 16(4):181–192. PubMed ID: 26219014 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of interfractional variation of the centroid position and volume of internal target volume during stereotactic body radiotherapy of lung cancer using cone-beam computed tomography. Sun Y; Ge H; Cheng S; Yang C; Zhu Q; Li D; Tian Y J Appl Clin Med Phys; 2016 Mar; 17(2):461-472. PubMed ID: 27074466 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage. Wang L; Hayes S; Paskalev K; Jin L; Buyyounouski MK; Ma CC; Feigenberg S Radiother Oncol; 2009 Jun; 91(3):314-24. PubMed ID: 19111362 [TBL] [Abstract][Full Text] [Related]
9. Dependence of volume dose indices on dose calculation algorithms for VMAT-SBRT plans for peripheral lung tumor. Matsuoka T; Araki F; Ohno T; Sakata J; Tominaga H Med Dosim; 2019 Autumn; 44(3):284-290. PubMed ID: 30455092 [TBL] [Abstract][Full Text] [Related]
10. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer. Tsuruta Y; Nakata M; Nakamura M; Matsuo Y; Higashimura K; Monzen H; Mizowaki T; Hiraoka M Med Phys; 2014 Aug; 41(8):081715. PubMed ID: 25086525 [TBL] [Abstract][Full Text] [Related]
11. Dosimetric Consequences of 3D Versus 4D PET/CT for Target Delineation of Lung Stereotactic Radiotherapy. Siva S; Chesson B; Callahan JW; Hardcastle N; Crawford L; Antippa P; Wright G; MacManus MP; Hicks RJ; Kron T; Ball DL J Thorac Oncol; 2015 Jul; 10(7):1112-5. PubMed ID: 26134229 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of Acuros XB algorithm based on RTOG 0813 dosimetric criteria for SBRT lung treatment with RapidArc. Rana S; Rogers K; Pokharel S; Cheng C J Appl Clin Med Phys; 2014 Jan; 15(1):4474. PubMed ID: 24423844 [TBL] [Abstract][Full Text] [Related]
13. Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms. Ong CCH; Ang KW; Soh RCX; Tin KM; Yap JHH; Lee JCL; Bragg CM Med Dosim; 2017 Autumn; 42(3):216-222. PubMed ID: 28711478 [TBL] [Abstract][Full Text] [Related]
14. Dosimetric Study of Deep Learning-Guided ITV Prediction in Cone-beam CT for Lung Stereotactic Body Radiotherapy. Zhang S; Lv B; Zheng X; Li Y; Ge W; Zhang L; Mo F; Qiu J Front Public Health; 2022; 10():860135. PubMed ID: 35392465 [TBL] [Abstract][Full Text] [Related]
15. Stereotactic radiotherapy of intrapulmonary lesions: comparison of different dose calculation algorithms for Oncentra MasterPlan®. Troeller A; Garny S; Pachmann S; Kantz S; Gerum S; Manapov F; Ganswindt U; Belka C; Söhn M Radiat Oncol; 2015 Feb; 10():51. PubMed ID: 25888786 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images. Wang L; Chen X; Lin MH; Xue J; Lin T; Fan J; Jin L; Ma CM Med Phys; 2013 Nov; 40(11):111709. PubMed ID: 24320417 [TBL] [Abstract][Full Text] [Related]
17. ITV versus mid-ventilation for treatment planning in lung SBRT: a comparison of target coverage and PTV adequacy by using in-treatment 4D cone beam CT. Bellec J; Arab-Ceschia F; Castelli J; Lafond C; Chajon E Radiat Oncol; 2020 Mar; 15(1):54. PubMed ID: 32127010 [TBL] [Abstract][Full Text] [Related]
18. Comparative analysis of delivered and planned doses in target volumes for lung stereotactic ablative radiotherapy. Yu GB; Kim JI; Kim HJ; Lee S; Choi CH; Kang S Radiat Oncol; 2024 Aug; 19(1):110. PubMed ID: 39152502 [TBL] [Abstract][Full Text] [Related]
19. A comparative planning study for lung SABR between tri-Co-60 magnetic resonance image guided radiation therapy system and volumetric modulated arc therapy. Park JM; Park SY; Kim HJ; Wu HG; Carlson J; Kim JI Radiother Oncol; 2016 Aug; 120(2):279-85. PubMed ID: 27401404 [TBL] [Abstract][Full Text] [Related]
20. Difference in target dose distributions between Acuros XB and collapsed cone convolution/superposition and the impact of the tumor locations in clinical cases of stereotactic ablative body radiotherapy for lung cancer. Inoue K; Matsukawa H; Kasai Y; Edamitsu K; Matsumoto K; Suetsugu Y; Hirose TA; Fukunaga JI; Shioyama Y; Sasaki T J Cancer Res Ther; 2023; 19(5):1261-1266. PubMed ID: 37787293 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]