269 related articles for article (PubMed ID: 25591037)
21. A real-time method to simultaneously measure linear energy transfer and dose for proton therapy using organic scintillators.
Alsanea F; Therriault-Proulx F; Sawakuchi G; Beddar S
Med Phys; 2018 Apr; 45(4):1782-1789. PubMed ID: 29446078
[TBL] [Abstract][Full Text] [Related]
22. A systematic characterization of the low-energy photon response of plastic scintillation detectors.
Boivin J; Beddar S; Bonde C; Schmidt D; Culberson W; Guillemette M; Beaulieu L
Phys Med Biol; 2016 Aug; 61(15):5569-86. PubMed ID: 27384872
[TBL] [Abstract][Full Text] [Related]
23. Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams.
Alsanea F; Darne C; Robertson D; Beddar S
Phys Med Biol; 2020 Apr; 65(7):075005. PubMed ID: 32079001
[TBL] [Abstract][Full Text] [Related]
24. Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.
Almurayshid M; Helo Y; Kacperek A; Griffiths J; Hebden J; Gibson A
J Appl Clin Med Phys; 2017 Sep; 18(5):210-219. PubMed ID: 28755419
[TBL] [Abstract][Full Text] [Related]
25. Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.
Wang LL; Beddar S
Med Phys; 2011 Mar; 38(3):1596-9. PubMed ID: 21520871
[TBL] [Abstract][Full Text] [Related]
26. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry.
Galavis PE; Hu L; Holmes S; Das IJ
Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221
[TBL] [Abstract][Full Text] [Related]
27. Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.
Resch AF; Heyes PD; Fuchs H; Bassler N; Georg D; Palmans H
Med Phys; 2020 Jun; 47(5):2289-2299. PubMed ID: 32166764
[TBL] [Abstract][Full Text] [Related]
28. Determination of the Range and Spread-Out Bragg Peak Width of Proton Beams Using a Large-Volume Liquid Scintillator.
Henry T; Robertson D; Therriault-Proulx F; Beddar S
Int J Part Ther; 2017; 4(1):1-6. PubMed ID: 31773000
[TBL] [Abstract][Full Text] [Related]
29. The visible signal responsible for proton therapy dosimetry using bare optical fibers is not Čerenkov radiation.
Darafsheh A; Taleei R; Kassaee A; Finlay JC
Med Phys; 2016 Nov; 43(11):5973. PubMed ID: 27806617
[TBL] [Abstract][Full Text] [Related]
30. Characterization of a plastic scintillating detector for the Small Animal Radiation Research Platform (SARRP).
Johnstone CD; Therriault-Proulx F; Beaulieu L; Bazalova-Carter M
Med Phys; 2019 Jan; 46(1):394-404. PubMed ID: 30417377
[TBL] [Abstract][Full Text] [Related]
31. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.
Gagnon JC; Thériault D; Guillot M; Archambault L; Beddar S; Gingras L; Beaulieu L
Med Phys; 2012 Jan; 39(1):429-36. PubMed ID: 22225313
[TBL] [Abstract][Full Text] [Related]
32. A procedure for calculation of monitor units for passively scattered proton radiotherapy beams.
Sahoo N; Zhu XR; Arjomandy B; Ciangaru G; Lii M; Amos R; Wu R; Gillin MT
Med Phys; 2008 Nov; 35(11):5088-97. PubMed ID: 19070243
[TBL] [Abstract][Full Text] [Related]
33. Proton beam dosimetry: a comparison between a plastic scintillator, ionization chamber and Faraday cup.
Ghergherehchi M; Afarideh H; Ghannadi M; Mohammadzadeh A; Aslani GR; Boghrati B
J Radiat Res; 2010; 51(4):423-30. PubMed ID: 20679742
[TBL] [Abstract][Full Text] [Related]
34. [Characterization of Small Volume Plastic Scintillation Detector].
Fukui Y; Hamada Y; Noma K; Harada N
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776
[TBL] [Abstract][Full Text] [Related]
35. Determination of the energy dependence of the BC-408 plastic scintillation detector in medium energy x-ray beams.
Yücel H; Çubukçu Ş; Uyar E; Engin Y
Phys Med Biol; 2014 Nov; 59(22):6749-58. PubMed ID: 25327627
[TBL] [Abstract][Full Text] [Related]
36. Evaluation of the dosimetric properties of a diode detector for small field proton radiosurgery.
McAuley GA; Teran AV; Slater JD; Slater JM; Wroe AJ
J Appl Clin Med Phys; 2015 Nov; 16(6):51-64. PubMed ID: 26699554
[TBL] [Abstract][Full Text] [Related]
37. Monte Carlo modeling of the influence of strong magnetic fields on the stem-effect in plastic scintillation detectors used in radiotherapy dosimetry.
Simiele E; Viscariello N; DeWerd L
Med Phys; 2021 Mar; 48(3):1381-1394. PubMed ID: 33283279
[TBL] [Abstract][Full Text] [Related]
38. Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy.
Takayanagi T; Nihongi H; Nishiuchi H; Tadokoro M; Ito Y; Nakashima C; Fujitaka S; Umezawa M; Matsuda K; Sakae T; Terunuma T
Med Phys; 2016 Jul; 43(7):4150. PubMed ID: 27370135
[TBL] [Abstract][Full Text] [Related]
39. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
Papaconstadopoulos P; Archambault L; Seuntjens J
Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
[TBL] [Abstract][Full Text] [Related]
40. Accurate calibration of a polymer gel dosimeter with a plastic scintillation detector.
Tremblay NM; Hubert-Tremblay V; Bujold R; Beddar AS; Beaulieu L; Lepage M
Med Phys; 2011 May; 38(5):2754-61. PubMed ID: 21776812
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]