These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 25594588)

  • 1. Kinect as a tool for gait analysis: validation of a real-time joint extraction algorithm working in side view.
    Cippitelli E; Gasparrini S; Spinsante S; Gambi E
    Sensors (Basel); 2015 Jan; 15(1):1417-34. PubMed ID: 25594588
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of the Microsoft Kinect for measuring gait parameters during treadmill walking.
    Xu X; McGorry RW; Chou LS; Lin JH; Chang CC
    Gait Posture; 2015 Jul; 42(2):145-51. PubMed ID: 26002604
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Novel Method of Human Joint Prediction in an Occlusion Scene by Using Low-cost Motion Capture Technique.
    Niu J; Wang X; Wang D; Ran L
    Sensors (Basel); 2020 Feb; 20(4):. PubMed ID: 32085653
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validity of time series kinematical data as measured by a markerless motion capture system on a flatland for gait assessment.
    Tanaka R; Takimoto H; Yamasaki T; Higashi A
    J Biomech; 2018 Apr; 71():281-285. PubMed ID: 29475751
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Accuracy of the Microsoft Kinect V2 Sensor for Human Gait Analysis. A Different Approach for Comparison with the Ground Truth.
    Guffanti D; Brunete A; Hernando M; Rueda J; Navarro Cabello E
    Sensors (Basel); 2020 Aug; 20(16):. PubMed ID: 32784586
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Full-body motion assessment: Concurrent validation of two body tracking depth sensors versus a gold standard system during gait.
    Vilas-Boas MDC; Choupina HMP; Rocha AP; Fernandes JM; Cunha JPS
    J Biomech; 2019 Apr; 87():189-196. PubMed ID: 30914189
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables.
    Mentiplay BF; Perraton LG; Bower KJ; Pua YH; McGaw R; Heywood S; Clark RA
    J Biomech; 2015 Jul; 48(10):2166-70. PubMed ID: 26065332
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Gait-Based Real-Time Gender Classification System Using Whole Body Joints.
    Azhar M; Ullah S; Ullah K; Syed I; Choi J
    Sensors (Basel); 2022 Nov; 22(23):. PubMed ID: 36501813
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The validity of the first and second generation Microsoft Kinectâ„¢ for identifying joint center locations during static postures.
    Xu X; McGorry RW
    Appl Ergon; 2015 Jul; 49():47-54. PubMed ID: 25766422
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Azure Kinect overground gait spatiotemporal parameters to marker based optical motion capture.
    Guess TM; Bliss R; Hall JB; Kiselica AM
    Gait Posture; 2022 Jul; 96():130-136. PubMed ID: 35635988
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard: A Pilot Study.
    Albert JA; Owolabi V; Gebel A; Brahms CM; Granacher U; Arnrich B
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32911651
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters.
    Dolatabadi E; Taati B; Mihailidis A
    Med Eng Phys; 2016 Sep; 38(9):952-8. PubMed ID: 27387901
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of an ambient system for the measurement of gait parameters.
    Dubois A; Bresciani JP
    J Biomech; 2018 Mar; 69():175-180. PubMed ID: 29397110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of lower extremity gait analysis using Kinect V2
    Usami T; Nishida K; Iguchi H; Okumura T; Sakai H; Ida R; Horiba M; Kashima S; Sahashi K; Asai H; Nagaya Y; Murakami H; Ueki Y; Kuroyanagi G
    SICOT J; 2022; 8():27. PubMed ID: 35748723
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of image data stream of a markerless motion capture system in determining the local dynamic stability and joint kinematics of human gait.
    Chakraborty S; Nandy A; Yamaguchi T; Bonnet V; Venture G
    J Biomech; 2020 May; 104():109718. PubMed ID: 32151378
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Unobtrusive, continuous, in-home gait measurement using the Microsoft Kinect.
    Stone EE; Skubic M
    IEEE Trans Biomed Eng; 2013 Oct; 60(10):2925-32. PubMed ID: 23744661
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spatiotemporal Gait Measurement With a Side-View Depth Sensor Using Human Joint Proposals.
    Hynes A; Czarnuch S; Kirkland MC; Ploughman M
    IEEE J Biomed Health Inform; 2021 May; 25(5):1758-1769. PubMed ID: 32946402
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a Kinect V2 based rehabilitation game.
    Ma M; Proffitt R; Skubic M
    PLoS One; 2018; 13(8):e0202338. PubMed ID: 30142631
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validity of the Kinect for Gait Assessment: A Focused Review.
    Springer S; Yogev Seligmann G
    Sensors (Basel); 2016 Feb; 16(2):194. PubMed ID: 26861323
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Review on the Use of Microsoft Kinect for Gait Abnormality and Postural Disorder Assessment.
    Bawa A; Banitsas K; Abbod M
    J Healthc Eng; 2021; 2021():4360122. PubMed ID: 34760141
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.