90 related articles for article (PubMed ID: 25599134)
1. A convection-driven long-range linear gradient generator with dynamic control.
Wang H; Chen CH; Xiang Z; Wang M; Lee C
Lab Chip; 2015 Mar; 15(6):1445-50. PubMed ID: 25599134
[TBL] [Abstract][Full Text] [Related]
2. On-chip gradient generation in 256 microfluidic cell cultures: simulation and experimental validation.
Somaweera H; Haputhanthri SO; Ibraguimov A; Pappas D
Analyst; 2015 Aug; 140(15):5029-38. PubMed ID: 26050759
[TBL] [Abstract][Full Text] [Related]
3. A robust diffusion-based gradient generator for dynamic cell assays.
Atencia J; Cooksey GA; Locascio LE
Lab Chip; 2012 Jan; 12(2):309-16. PubMed ID: 22113489
[TBL] [Abstract][Full Text] [Related]
4. Generation of dynamic temporal and spatial concentration gradients using microfluidic devices.
Lin F; Saadi W; Rhee SW; Wang SJ; Mittal S; Jeon NL
Lab Chip; 2004 Jun; 4(3):164-7. PubMed ID: 15159771
[TBL] [Abstract][Full Text] [Related]
5. A polydimethylsiloxane-polycarbonate hybrid microfluidic device capable of generating perpendicular chemical and oxygen gradients for cell culture studies.
Chang CW; Cheng YJ; Tu M; Chen YH; Peng CC; Liao WH; Tung YC
Lab Chip; 2014 Oct; 14(19):3762-72. PubMed ID: 25096368
[TBL] [Abstract][Full Text] [Related]
6. Microfluidic gradient PCR (MG-PCR): a new method for microfluidic DNA amplification.
Zhang C; Xing D
Biomed Microdevices; 2010 Feb; 12(1):1-12. PubMed ID: 19757072
[TBL] [Abstract][Full Text] [Related]
7. Analysis of 3D multi-layer microfluidic gradient generator.
Ha JH; Kim TH; Lee JM; Ahrberg CD; Chung BG
Electrophoresis; 2017 Jan; 38(2):270-277. PubMed ID: 27801504
[TBL] [Abstract][Full Text] [Related]
8. Diffusion- and convection-based activation of Wnt/β-catenin signaling in a gradient generating microfluidic chip.
Kim C; Kreppenhofer K; Kashef J; Gradl D; Herrmann D; Schneider M; Ahrens R; Guber A; Wedlich D
Lab Chip; 2012 Dec; 12(24):5186-94. PubMed ID: 23108330
[TBL] [Abstract][Full Text] [Related]
9. A simple and versatile microfluidic cell density gradient generator for quantum dot cytotoxicity assay.
Wu J; Chen Q; Liu W; Lin JM
Lab Chip; 2013 May; 13(10):1948-54. PubMed ID: 23538998
[TBL] [Abstract][Full Text] [Related]
10. Concentration gradient generator using a convective-diffusive balance.
Kang T; Han J; Lee KS
Lab Chip; 2008 Jul; 8(7):1220-2. PubMed ID: 18584102
[TBL] [Abstract][Full Text] [Related]
11. A tuneable array of unique steady-state microfluidic gradients.
Estes MD; Hurth C; Barrett M; Zenhausern F
Phys Chem Chem Phys; 2013 Aug; 15(31):12805-14. PubMed ID: 23636584
[TBL] [Abstract][Full Text] [Related]
12. A microfluidic device with passive air-bubble valves for real-time measurement of dose-dependent drug cytotoxicity through impedance sensing.
Xu Y; Lv Y; Wang L; Xing W; Cheng J
Biosens Bioelectron; 2012 Feb; 32(1):300-4. PubMed ID: 22208957
[TBL] [Abstract][Full Text] [Related]
13. A microfluidic device mimicking acinar concentration gradients across the liver acinus.
Shih MC; Tseng SH; Weng YS; Chu IM; Liu CH
Biomed Microdevices; 2013 Oct; 15(5):767-80. PubMed ID: 23563756
[TBL] [Abstract][Full Text] [Related]
14. Generation of linear and non-linear concentration gradients along microfluidic channel by microtunnel controlled stepwise addition of sample solution.
Li CW; Chen R; Yang M
Lab Chip; 2007 Oct; 7(10):1371-3. PubMed ID: 17896024
[TBL] [Abstract][Full Text] [Related]
15. A parallel-gradient microfluidic chamber for quantitative analysis of breast cancer cell chemotaxis.
Saadi W; Wang SJ; Lin F; Jeon NL
Biomed Microdevices; 2006 Jun; 8(2):109-18. PubMed ID: 16688570
[TBL] [Abstract][Full Text] [Related]
16. Rapid generation of spatially and temporally controllable long-range concentration gradients in a microfluidic device.
Du Y; Shim J; Vidula M; Hancock MJ; Lo E; Chung BG; Borenstein JT; Khabiry M; Cropek DM; Khademhosseini A
Lab Chip; 2009 Mar; 9(6):761-7. PubMed ID: 19255657
[TBL] [Abstract][Full Text] [Related]
17. A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis.
Diao J; Young L; Kim S; Fogarty EA; Heilman SM; Zhou P; Shuler ML; Wu M; DeLisa MP
Lab Chip; 2006 Mar; 6(3):381-8. PubMed ID: 16511621
[TBL] [Abstract][Full Text] [Related]
18. Microfluidic geometric metering-based multi-reagent mixture generator for robust live cell screening array.
Wang H; Kim J; Jayaraman A; Han A
Biomed Microdevices; 2014 Dec; 16(6):887-96. PubMed ID: 25112181
[TBL] [Abstract][Full Text] [Related]
19. Flow-through sensor array applied to cytotoxicity assessment in cell cultures for drug-testing purposes.
Witkowska Nery E; Jastrzębska E; Żukowski K; Wróblewski W; Chudy M; Ciosek P
Biosens Bioelectron; 2014 Jan; 51():55-61. PubMed ID: 23932980
[TBL] [Abstract][Full Text] [Related]
20. Generation of oxygen gradients in microfluidic devices for cell culture using spatially confined chemical reactions.
Chen YA; King AD; Shih HC; Peng CC; Wu CY; Liao WH; Tung YC
Lab Chip; 2011 Nov; 11(21):3626-33. PubMed ID: 21915399
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]