These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
76 related articles for article (PubMed ID: 25604601)
1. Can Mismatch Negativity Reduce Uncertainty in the Prediction of Awakening From Coma During Extracorporeal Membrane Oxygenation? Rodriguez RA; Shamy M; Dowlatshahi D; Nathan HJ J Cardiothorac Vasc Anesth; 2015 Dec; 29(6):1627-31. PubMed ID: 25604601 [No Abstract] [Full Text] [Related]
2. Auditory mismatch negativity is a good predictor of awakening in comatose patients: a fast and reliable procedure. Naccache L; Puybasset L; Gaillard R; Serve E; Willer JC Clin Neurophysiol; 2005 Apr; 116(4):988-9. PubMed ID: 15792909 [No Abstract] [Full Text] [Related]
3. Auditory-evoked potentials during coma: do they improve our prediction of awakening in comatose patients? Rodriguez RA; Bussière M; Froeschl M; Nathan HJ J Crit Care; 2014 Feb; 29(1):93-100. PubMed ID: 24125771 [TBL] [Abstract][Full Text] [Related]
4. Improved prediction of awakening or nonawakening from severe anoxic coma using tree-based classification analysis. Fischer C; Luauté J; Némoz C; Morlet D; Kirkorian G; Mauguière F Crit Care Med; 2006 May; 34(5):1520-4. PubMed ID: 16557163 [TBL] [Abstract][Full Text] [Related]
5. Clinical significance of mismatch negativity in predicting the awakening of comatose patients after severe brain injury. Zhou L; Wang J; Wu Y; Liu ZY; Yu Y; Liu JF; Chen X J Neurophysiol; 2021 Jul; 126(1):140-147. PubMed ID: 34038175 [TBL] [Abstract][Full Text] [Related]
6. Progression of auditory discrimination based on neural decoding predicts awakening from coma. Tzovara A; Rossetti AO; Spierer L; Grivel J; Murray MM; Oddo M; De Lucia M Brain; 2013 Jan; 136(Pt 1):81-9. PubMed ID: 23148350 [TBL] [Abstract][Full Text] [Related]
7. Sensory and cognitive evoked potentials in the prognosis of coma. Fischer C; Morlet D; Luaute J Suppl Clin Neurophysiol; 2004; 57():656-61. PubMed ID: 16106667 [No Abstract] [Full Text] [Related]
8. Prognostic value of evoked responses and event-related brain potentials in coma. Wang JT; Young GB; Connolly JF Can J Neurol Sci; 2004 Nov; 31(4):438-50. PubMed ID: 15595246 [TBL] [Abstract][Full Text] [Related]
9. Evoked potentials for the prediction of vegetative state in the acute stage of coma. Fischer C; Luauté J Neuropsychol Rehabil; 2005; 15(3-4):372-80. PubMed ID: 16350978 [TBL] [Abstract][Full Text] [Related]
10. Predicting coma and other low responsive patients outcome using event-related brain potentials: a meta-analysis. Daltrozzo J; Wioland N; Mutschler V; Kotchoubey B Clin Neurophysiol; 2007 Mar; 118(3):606-14. PubMed ID: 17208048 [TBL] [Abstract][Full Text] [Related]
11. Coma outcome prediction using event-related potentials: P(3) and mismatch negativity. Kane NM; Butler SR; Simpson T Audiol Neurootol; 2000; 5(3-4):186-91. PubMed ID: 10859412 [TBL] [Abstract][Full Text] [Related]
12. Auditory evoked potentials at 40 Hz (SSR40Hz) in post-trauma coma patients. Serafini G; Acra W; Scuteri F; Palmieri AM; Simoncelli C Laryngoscope; 1994 Feb; 104(2):182-4. PubMed ID: 8302121 [TBL] [Abstract][Full Text] [Related]
13. [Auditive and somato-sensory event-related potentials in comas: prognostic value for awakening, social and professional reinstatement]. Grapperon J; Vidal F; Bruschera D; Cantais E; Salinier L; Costes O; Palmier B Ann Fr Anesth Reanim; 2004 Mar; 23(2):102-8. PubMed ID: 15030858 [TBL] [Abstract][Full Text] [Related]
14. Prediction of 'awakening' and outcome in prolonged acute coma from severe traumatic brain injury: evidence for validity of short latency SEPs. Amantini A; Grippo A; Fossi S; Cesaretti C; Piccioli A; Peris A; Ragazzoni A; Pinto F Clin Neurophysiol; 2005 Jan; 116(1):229-35. PubMed ID: 15589201 [TBL] [Abstract][Full Text] [Related]
15. Automated auditory mismatch negativity paradigm improves coma prognostic accuracy after cardiac arrest and therapeutic hypothermia. Rossetti AO; Tzovara A; Murray MM; De Lucia M; Oddo M J Clin Neurophysiol; 2014 Aug; 31(4):356-61. PubMed ID: 25083848 [TBL] [Abstract][Full Text] [Related]
16. Coma: pathophysiology and procedure guide. Casanova MF Bol Asoc Med P R; 1984 Dec; 76(12):524-8. PubMed ID: 6596957 [No Abstract] [Full Text] [Related]
17. Neurologic outcome in children after extracorporeal membrane oxygenation: prognostic value of diagnostic tests. Amigoni A; Pettenazzo A; Biban P; Suppiej A; Freato F; Zaramella P; Zacchello F Pediatr Neurol; 2005 Mar; 32(3):173-9. PubMed ID: 15730897 [TBL] [Abstract][Full Text] [Related]
18. Neuropathological findings in comatose patients with venoarterial extracorporeal membrane oxygenation. Cho SM; Geocadin RG; White B; Chen LL Int J Artif Organs; 2020 Sep; 43(9):614-619. PubMed ID: 31992109 [TBL] [Abstract][Full Text] [Related]
19. Predictive value of electrophysiology in children with hypoxic coma. Mewasingh LD; Christophe C; Fonteyne C; Dachy B; Ziereisen F; Christiaens F; Deltenre P; De Maertelaer V; Dan B Pediatr Neurol; 2003 Mar; 28(3):178-83. PubMed ID: 12770669 [TBL] [Abstract][Full Text] [Related]
20. [Neurophysiological diagnosis of the patient in coma]. Chaparro Hernández P Rev Neurol; 2001 Mar 16-31; 32(6):542-5. PubMed ID: 11353994 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]