These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 25605539)

  • 1. Rare event counting of CD59- red cells in human blood: A 47-month experience using PNH consensus guidelines for WBC and RBC testing in a reference lab.
    Liew M; Farley M; Andreasen J; Parker CJ; Wittwer CT
    Cytometry B Clin Cytom; 2015; 88(4):261-9. PubMed ID: 25605539
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnosing PNH with FLAER and multiparameter flow cytometry.
    Sutherland DR; Kuek N; Davidson J; Barth D; Chang H; Yeo E; Bamford S; Chin-Yee I; Keeney M
    Cytometry B Clin Cytom; 2007 May; 72(3):167-77. PubMed ID: 17285629
    [TBL] [Abstract][Full Text] [Related]  

  • 3. CD71 improves delineation of PNH type III, PNH type II, and normal immature RBCS in patients with paroxysmal nocturnal hemoglobinuria.
    Sutherland DR; Richards SJ; Ortiz F; Nayyar R; Benko M; Marinov I; Illingworth A
    Cytometry B Clin Cytom; 2020 Mar; 98(2):179-192. PubMed ID: 31705743
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnosis of paroxysmal nocturnal hemoglobinuria in peripheral blood and bone marrow with six-color flow cytometry.
    Yang HS; Yang M; Li X; Tugulea S; Dong H
    Biomark Med; 2013 Feb; 7(1):99-111. PubMed ID: 23387491
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Practical guidelines for the high-sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometry.
    Sutherland DR; Keeney M; Illingworth A
    Cytometry B Clin Cytom; 2012 Jul; 82(4):195-208. PubMed ID: 22499484
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow cytometry screening for paroxysmal nocturnal hemoglobinuria: A single-center experience in Saudi Arabia.
    AlGhasham N; Abulkhair Y; Khalil S
    Cytometry B Clin Cytom; 2015; 88(6):389-94. PubMed ID: 26296648
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intra- and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high-sensitivity paroxysmal nocturnal hemoglobinuria testing.
    Marinov I; Kohoutová M; Tkáčová V; Lysák D; Holubová M; Stehlíková O; Železníková T; Žontar D; Illingworth A
    Cytometry B Clin Cytom; 2013; 84(4):229-36. PubMed ID: 23325604
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Protection of PNH red blood cells from lysis by transferring GPI-anchored protein vesicles of normal human RBCs in vitro].
    Yang Y; Xu C; Pan H
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 1999 Aug; 21(4):278-81. PubMed ID: 12567450
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of a FLAER-based WBC assay in the primary screening of PNH clones.
    Sutherland DR; Kuek N; Azcona-Olivera J; Anderson T; Acton E; Barth D; Keeney M
    Am J Clin Pathol; 2009 Oct; 132(4):564-72. PubMed ID: 19762534
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemia.
    Sachdeva MU; Varma N; Chandra D; Bose P; Malhotra P; Varma S
    Ann Hematol; 2015 May; 94(5):721-8. PubMed ID: 25465235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. FLAER as a standalone reagent for paroxysmal nocturnal hemoglobinuria: Do we need to reconsider the guidelines for testing?
    Sharma P; Bose P; Mallik N; Gupta DG; Rachagiri S; Kumar A; Kaur J; Malhotra P; Varma N; Sachdeva MUS
    Int J Lab Hematol; 2024 Apr; 46(2):383-389. PubMed ID: 38069562
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The clinical implication of detection of CD59(-) cells in paroxysmal nocturnal hemoglobinuria].
    Lü ZJ; Du T; Zhang Z
    Zhonghua Xue Ye Xue Za Zhi; 1997 Oct; 18(10):513-6. PubMed ID: 15625824
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Robust in vitro replication of Plasmodium falciparum in glycosyl-phosphatidylinositol-anchored membrane glycoprotein-deficient red blood cells.
    Pattanapanyasat K; Walsh DS; Yongvanitchit K; Piyawatthanasakul N; Wanachiwanawin W; Webster HK
    Am J Trop Med Hyg; 2003 Oct; 69(4):360-5. PubMed ID: 14640493
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Blood cell flow cytometry in paroxysmal nocturnal hemoglobinuria: a tool for measuring the extent of the PNH clone.
    Alfinito F; Del Vecchio L; Rocco S; Boccuni P; Musto P; Rotoli B
    Leukemia; 1996 Aug; 10(8):1326-30. PubMed ID: 8709638
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel marker for screening paroxysmal nocturnal hemoglobinuria using routine complete blood count and cell population data.
    Kahng J; Kim Y; Kim JO; Koh K; Lee JW; Han K
    Ann Lab Med; 2015 Jan; 35(1):35-40. PubMed ID: 25553278
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Shortened lifespan of paroxysmal nocturnal haemoglobinuria-affected RBC estimated from differences in ratios of CD59-negative populations between reticulocytes and whole RBC.
    Ninomiya H; Sato S; Hasegawa Y; Nagasawa T
    Int J Lab Hematol; 2008 Feb; 30(1):41-5. PubMed ID: 18190466
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-sensitivity 5-, 6-, and 7-color PNH WBC assays for both Canto II and Navios platforms.
    Sutherland DR; Ortiz F; Quest G; Illingworth A; Benko M; Nayyar R; Marinov I
    Cytometry B Clin Cytom; 2018 Jul; 94(4):637-651. PubMed ID: 29381839
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Immunophenotyping of Paroxysmal Nocturnal Hemoglobinuria (PNH).
    Illingworth AJ; Marinov I; Sutherland DR
    Methods Mol Biol; 2019; 2032():323-354. PubMed ID: 31522427
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Standardized high-sensitivity flow cytometry testing for paroxysmal nocturnal hemoglobinuria in children with acquired bone marrow failure disorders: A single center US study.
    Donohue RE; Marcogliese AN; Sasa GS; Elghetany MT; Redkar AA; Bertuch AA; Curry CV
    Cytometry B Clin Cytom; 2018 Jul; 94(4):699-704. PubMed ID: 28574201
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-Sensitivity Detection of PNH Red Blood Cells, Red Cell Precursors, and White Blood Cells.
    Sutherland DR; Illingworth A; Keeney M; Richards SJ
    Curr Protoc Cytom; 2015 Apr; 72():6.37.1-6.37.29. PubMed ID: 25827482
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.