234 related articles for article (PubMed ID: 25607538)
1. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.
Leuthold LA; Heudi O; Déglon J; Raccuglia M; Augsburger M; Picard F; Kretz O; Thomas A
Anal Chem; 2015 Feb; 87(4):2068-71. PubMed ID: 25607538
[TBL] [Abstract][Full Text] [Related]
2. Precise, accurate and user-independent blood collection system for dried blood spot sample preparation.
Neto R; Gooley A; Breadmore MC; Hilder EF; Lapierre F
Anal Bioanal Chem; 2018 May; 410(14):3315-3323. PubMed ID: 29623384
[TBL] [Abstract][Full Text] [Related]
3. Investigation of the effect of blood hematocrit and lipid content on the blood volume deposited by a disposable dried blood spot collection device.
Spooner N; Olatunji A; Webbley K
J Pharm Biomed Anal; 2018 Feb; 149():419-424. PubMed ID: 29154197
[TBL] [Abstract][Full Text] [Related]
4. Hematocrit-Independent Quantitation of Stimulants in Dried Blood Spots: Pipet versus Microfluidic-Based Volumetric Sampling Coupled with Automated Flow-Through Desorption and Online Solid Phase Extraction-LC-MS/MS Bioanalysis.
Verplaetse R; Henion J
Anal Chem; 2016 Jul; 88(13):6789-96. PubMed ID: 27270226
[TBL] [Abstract][Full Text] [Related]
5. A device for dried blood microsampling in quantitative bioanalysis: overcoming the issues associated blood hematocrit.
Spooner N; Denniff P; Michielsen L; De Vries R; Ji QC; Arnold ME; Woods K; Woolf EJ; Xu Y; Boutet V; Zane P; Kushon S; Rudge JB
Bioanalysis; 2015; 7(6):653-9. PubMed ID: 25514576
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of the Capitainer-B Microfluidic Device as a New Hematocrit-Independent Alternative for Dried Blood Spot Collection.
Velghe S; Stove CP
Anal Chem; 2018 Nov; 90(21):12893-12899. PubMed ID: 30256092
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of a Volumetric Dried Blood Spot Card Using a Gravimetric Method and a Bioanalytical Method with Capillary Blood from 44 Volunteers.
Lenk G; Ullah S; Stemme G; Beck O; Roxhed N
Anal Chem; 2019 May; 91(9):5558-5565. PubMed ID: 30856315
[TBL] [Abstract][Full Text] [Related]
8. Prediction of the hematocrit of dried blood spots via potassium measurement on a routine clinical chemistry analyzer.
Capiau S; Stove VV; Lambert WE; Stove CP
Anal Chem; 2013 Jan; 85(1):404-10. PubMed ID: 23190205
[TBL] [Abstract][Full Text] [Related]
9. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.
De Kesel PM; Lambert WE; Stove CP
Anal Chim Acta; 2015 Jun; 881():65-73. PubMed ID: 26041521
[TBL] [Abstract][Full Text] [Related]
10. Hemato-critical issues in quantitative analysis of dried blood spots: challenges and solutions.
De Kesel PM; Sadones N; Capiau S; Lambert WE; Stove CP
Bioanalysis; 2013 Aug; 5(16):2023-41. PubMed ID: 23937137
[TBL] [Abstract][Full Text] [Related]
11. Near-infrared-based hematocrit prediction of dried blood spots: An in-depth evaluation.
Delahaye L; Heughebaert L; Lühr C; Lambrecht S; Stove CP
Clin Chim Acta; 2021 Dec; 523():239-246. PubMed ID: 34624275
[TBL] [Abstract][Full Text] [Related]
12. Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis.
Denniff P; Spooner N
Anal Chem; 2014 Aug; 86(16):8489-95. PubMed ID: 25058158
[TBL] [Abstract][Full Text] [Related]
13. Determination of moxifloxacin in dried blood spots using LC-MS/MS and the impact of the hematocrit and blood volume.
Vu DH; Koster RA; Alffenaar JW; Brouwers JR; Uges DR
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 May; 879(15-16):1063-70. PubMed ID: 21459055
[TBL] [Abstract][Full Text] [Related]
14. Potassium-based algorithm allows correction for the hematocrit bias in quantitative analysis of caffeine and its major metabolite in dried blood spots.
De Kesel PM; Capiau S; Stove VV; Lambert WE; Stove CP
Anal Bioanal Chem; 2014 Oct; 406(26):6749-55. PubMed ID: 25168119
[TBL] [Abstract][Full Text] [Related]
15. A disposable sampling device to collect volume-measured DBS directly from a fingerprick onto DBS paper.
Lenk G; Sandkvist S; Pohanka A; Stemme G; Beck O; Roxhed N
Bioanalysis; 2015; 7(16):2085-94. PubMed ID: 26327187
[TBL] [Abstract][Full Text] [Related]
16. Perforated dried blood spot accurate microsampling: the concept and its applications in toxicokinetic sample collection.
Li F; Ploch S; Fast D; Michael S
J Mass Spectrom; 2012 May; 47(5):655-67. PubMed ID: 22576879
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the Performance and Hematocrit Independence of the HemaPEN as a Volumetric Dried Blood Spot Collection Device.
Deprez S; Paniagua-González L; Velghe S; Stove CP
Anal Chem; 2019 Nov; 91(22):14467-14475. PubMed ID: 31638372
[TBL] [Abstract][Full Text] [Related]
18. The effect of hematocrit and punch location on assay bias during quantitative bioanalysis of dried blood spot samples.
O'Mara M; Hudson-Curtis B; Olson K; Yueh Y; Dunn J; Spooner N
Bioanalysis; 2011 Oct; 3(20):2335-47. PubMed ID: 22011181
[TBL] [Abstract][Full Text] [Related]
19. Correction for the Hematocrit Bias in Dried Blood Spot Analysis Using a Nondestructive, Single-Wavelength Reflectance-Based Hematocrit Prediction Method.
Capiau S; Wilk LS; De Kesel PMM; Aalders MCG; Stove CP
Anal Chem; 2018 Feb; 90(3):1795-1804. PubMed ID: 29281263
[TBL] [Abstract][Full Text] [Related]
20. Analysis of ochratoxin A in dried blood spots - Correlation between venous and finger-prick blood, the influence of hematocrit and spotted volume.
Osteresch B; Cramer B; Humpf HU
J Chromatogr B Analyt Technol Biomed Life Sci; 2016 May; 1020():158-64. PubMed ID: 27046696
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]