339 related articles for article (PubMed ID: 25611012)
1. 8-mm versus 10-mm diameter self-expandable metallic stent in bilateral endoscopic stent-in-stent deployment for malignant hilar biliary obstruction.
Naitoh I; Nakazawa T; Ban T; Okumura F; Hirano A; Takada H; Togawa S; Hayashi K; Miyabe K; Shimizu S; Kondo H; Nishi Y; Yoshida M; Yamashita H; Umemura S; Hori Y; Kato A; Sano H; Joh T
J Hepatobiliary Pancreat Sci; 2015 May; 22(5):396-401. PubMed ID: 25611012
[TBL] [Abstract][Full Text] [Related]
2. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.
Inoue T; Naitoh I; Okumura F; Ozeki T; Anbe K; Iwasaki H; Nishie H; Mizushima T; Sano H; Nakazawa T; Yoneda M; Joh T
Dig Endosc; 2016 Nov; 28(7):731-737. PubMed ID: 27088888
[TBL] [Abstract][Full Text] [Related]
3. Endoscopic re-intervention after stent-in-stent versus side-by-side bilateral self-expandable metallic stent deployment.
Iwai T; Kida M; Okuwaki K; Yamauchi H; Kaneko T; Hasegawa R; Watanabe M; Kurosu T; Imaizumi H; Koizumi W
J Gastroenterol Hepatol; 2022 Jun; 37(6):1060-1066. PubMed ID: 35261069
[TBL] [Abstract][Full Text] [Related]
4. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction.
Heo JY; Lee HS; Son JH; Lee SH; Bang S
Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315
[TBL] [Abstract][Full Text] [Related]
5. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction.
Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M
Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163
[TBL] [Abstract][Full Text] [Related]
6. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT
Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195
[TBL] [Abstract][Full Text] [Related]
7. Small cell- versus large cell-sized metal stent in endoscopic bilateral stent-in-stent placement for malignant hilar biliary obstruction.
Lee JM; Lee SH; Chung KH; Park JM; Paik WH; Woo SM; Lee WJ; Ryu JK; Kim YT
Dig Endosc; 2015 Sep; 27(6):692-9. PubMed ID: 25708157
[TBL] [Abstract][Full Text] [Related]
8. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.
Kogure H; Isayama H; Nakai Y; Tsujino T; Matsubara S; Yashima Y; Ito Y; Hamada T; Takahara N; Miyabayashi K; Mizuno S; Mohri D; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tada M; Koike K
Dig Endosc; 2014 Jan; 26(1):93-9. PubMed ID: 23517109
[TBL] [Abstract][Full Text] [Related]
9. Endoscopic reintervention after unilateral metal stent deployment for MHBO using SIS method.
Yue Q; Han W; Liu ZL
Medicine (Baltimore); 2023 Jul; 102(30):e34467. PubMed ID: 37505126
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction.
Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M
J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234
[TBL] [Abstract][Full Text] [Related]
11. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.
Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H
World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893
[TBL] [Abstract][Full Text] [Related]
12. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.
Jiao D; Huang K; Zhu M; Wu G; Ren J; Wang Y; Han X
Dig Dis Sci; 2017 Jan; 62(1):253-263. PubMed ID: 27586033
[TBL] [Abstract][Full Text] [Related]
13. Prospective multicenter evaluation of moving cell metallic stents in endoscopic multiple stent deployment for hepatic hilar obstruction.
Kawai J; Ogura T; Takenaka M; Shiomi H; Ueshima K; Ueno S; Okuda A; Matsuno J; Minaga K; Omoto S; Nakai A; Ikegawa T; Hakoda A; Higuchi K
J Hepatobiliary Pancreat Sci; 2022 Nov; 29(11):1195-1203. PubMed ID: 34110699
[TBL] [Abstract][Full Text] [Related]
14. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.
Mukai T; Yasuda I; Isayama H; Iwashita T; Itoi T; Kawakami H; Kogure H; Nakai Y
Dig Endosc; 2016 Sep; 28(6):671-9. PubMed ID: 26927207
[TBL] [Abstract][Full Text] [Related]
15. Benefits of side-by-side deployment of 6-mm covered self-expandable metal stents for hilar malignant biliary obstructions.
Yoshida T; Hara K; Imaoka H; Hijioka S; Mizuno N; Ishihara M; Tanaka T; Tajika M; Niwa Y; Yamao K
J Hepatobiliary Pancreat Sci; 2016 Sep; 23(9):548-55. PubMed ID: 27345771
[TBL] [Abstract][Full Text] [Related]
16. Retrospective evaluation of slim fully covered self-expandable metallic stent for unresectable malignant hilar biliary obstruction.
Takahashi S; Fujisawa T; Ushio M; Fukuma T; Suzuki A; Takasaki Y; Ito K; Tomishima K; Ishii S; Isayama H
J Hepatobiliary Pancreat Sci; 2023 Mar; 30(3):408-415. PubMed ID: 35918901
[TBL] [Abstract][Full Text] [Related]
17. Feasibility of the placement of a novel 6-mm diameter threaded fully covered self-expandable metal stent for malignant hilar biliary obstructions (with videos).
Inoue T; Okumura F; Naitoh I; Fukusada S; Kachi K; Ozeki T; Anbe K; Iwasaki H; Mizushima T; Kobayashi Y; Ishii N; Ito K; Kondo H; Hayashi K; Yoneda M; Sano H
Gastrointest Endosc; 2016 Aug; 84(2):352-7. PubMed ID: 27060713
[TBL] [Abstract][Full Text] [Related]
18. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.
Kawakubo K; Kawakami H; Kuwatani M; Kudo T; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
J Hepatobiliary Pancreat Sci; 2015 Feb; 22(2):151-5. PubMed ID: 25345586
[TBL] [Abstract][Full Text] [Related]
19. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent.
Park JM; Lee SH; Chung KH; Jang DK; Ryu JK; Kim YT; Lee JM; Paik WH
Hepatobiliary Pancreat Dis Int; 2016 Dec; 15(6):633-639. PubMed ID: 27919853
[TBL] [Abstract][Full Text] [Related]
20. Usefulness of a newly designed plastic stent for endoscopic re-intervention in patients with malignant hilar biliary obstruction.
Tomoda T; Kato H; Kawamoto H; Muro S; Akimoto Y; Uchida D; Matsumoto K; Horiguchi S; Tsutsumi K; Okada H
Endoscopy; 2017 Nov; 49(11):1087-1091. PubMed ID: 28753695
[No Abstract] [Full Text] [Related]
[Next] [New Search]