These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Endoscopic re-intervention after stent-in-stent versus side-by-side bilateral self-expandable metallic stent deployment. Iwai T; Kida M; Okuwaki K; Yamauchi H; Kaneko T; Hasegawa R; Watanabe M; Kurosu T; Imaizumi H; Koizumi W J Gastroenterol Hepatol; 2022 Jun; 37(6):1060-1066. PubMed ID: 35261069 [TBL] [Abstract][Full Text] [Related]
4. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction. Heo JY; Lee HS; Son JH; Lee SH; Bang S Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315 [TBL] [Abstract][Full Text] [Related]
5. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction. Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163 [TBL] [Abstract][Full Text] [Related]
6. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction. Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195 [TBL] [Abstract][Full Text] [Related]
7. Small cell- versus large cell-sized metal stent in endoscopic bilateral stent-in-stent placement for malignant hilar biliary obstruction. Lee JM; Lee SH; Chung KH; Park JM; Paik WH; Woo SM; Lee WJ; Ryu JK; Kim YT Dig Endosc; 2015 Sep; 27(6):692-9. PubMed ID: 25708157 [TBL] [Abstract][Full Text] [Related]
8. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction. Kogure H; Isayama H; Nakai Y; Tsujino T; Matsubara S; Yashima Y; Ito Y; Hamada T; Takahara N; Miyabayashi K; Mizuno S; Mohri D; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tada M; Koike K Dig Endosc; 2014 Jan; 26(1):93-9. PubMed ID: 23517109 [TBL] [Abstract][Full Text] [Related]
10. Endoscopic reintervention after unilateral metal stent deployment for MHBO using SIS method. Yue Q; Han W; Liu ZL Medicine (Baltimore); 2023 Jul; 102(30):e34467. PubMed ID: 37505126 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction. Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234 [TBL] [Abstract][Full Text] [Related]
12. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction. Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893 [TBL] [Abstract][Full Text] [Related]
13. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study. Jiao D; Huang K; Zhu M; Wu G; Ren J; Wang Y; Han X Dig Dis Sci; 2017 Jan; 62(1):253-263. PubMed ID: 27586033 [TBL] [Abstract][Full Text] [Related]
15. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies. Mukai T; Yasuda I; Isayama H; Iwashita T; Itoi T; Kawakami H; Kogure H; Nakai Y Dig Endosc; 2016 Sep; 28(6):671-9. PubMed ID: 26927207 [TBL] [Abstract][Full Text] [Related]
16. Benefits of side-by-side deployment of 6-mm covered self-expandable metal stents for hilar malignant biliary obstructions. Yoshida T; Hara K; Imaoka H; Hijioka S; Mizuno N; Ishihara M; Tanaka T; Tajika M; Niwa Y; Yamao K J Hepatobiliary Pancreat Sci; 2016 Sep; 23(9):548-55. PubMed ID: 27345771 [TBL] [Abstract][Full Text] [Related]
17. Retrospective evaluation of slim fully covered self-expandable metallic stent for unresectable malignant hilar biliary obstruction. Takahashi S; Fujisawa T; Ushio M; Fukuma T; Suzuki A; Takasaki Y; Ito K; Tomishima K; Ishii S; Isayama H J Hepatobiliary Pancreat Sci; 2023 Mar; 30(3):408-415. PubMed ID: 35918901 [TBL] [Abstract][Full Text] [Related]
18. Feasibility of the placement of a novel 6-mm diameter threaded fully covered self-expandable metal stent for malignant hilar biliary obstructions (with videos). Inoue T; Okumura F; Naitoh I; Fukusada S; Kachi K; Ozeki T; Anbe K; Iwasaki H; Mizushima T; Kobayashi Y; Ishii N; Ito K; Kondo H; Hayashi K; Yoneda M; Sano H Gastrointest Endosc; 2016 Aug; 84(2):352-7. PubMed ID: 27060713 [TBL] [Abstract][Full Text] [Related]
19. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study. Kawakubo K; Kawakami H; Kuwatani M; Kudo T; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N J Hepatobiliary Pancreat Sci; 2015 Feb; 22(2):151-5. PubMed ID: 25345586 [TBL] [Abstract][Full Text] [Related]
20. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent. Park JM; Lee SH; Chung KH; Jang DK; Ryu JK; Kim YT; Lee JM; Paik WH Hepatobiliary Pancreat Dis Int; 2016 Dec; 15(6):633-639. PubMed ID: 27919853 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]