These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 25614385)

  • 1. Experimental evaluation and computational modeling of tissue damage from low-flow push-pull perfusion sampling in vivo.
    Cepeda DE; Hains L; Li D; Bull J; Lentz SI; Kennedy RT
    J Neurosci Methods; 2015 Mar; 242():97-105. PubMed ID: 25614385
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Demonstration of low flow push-pull perfusion.
    Kottegoda S; Shaik I; Shippy SA
    J Neurosci Methods; 2002 Nov; 121(1):93-101. PubMed ID: 12393165
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Push-pull perfusion sampling with segmented flow for high temporal and spatial resolution in vivo chemical monitoring.
    Slaney TR; Nie J; Hershey ND; Thwar PK; Linderman J; Burns MA; Kennedy RT
    Anal Chem; 2011 Jul; 83(13):5207-13. PubMed ID: 21604670
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microfluidic chip for low-flow push-pull perfusion sampling in vivo with on-line analysis of amino acids.
    Cellar NA; Burns ST; Meiners JC; Chen H; Kennedy RT
    Anal Chem; 2005 Nov; 77(21):7067-73. PubMed ID: 16255611
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simultaneous comparison of cerebral dialysis and push-pull perfusion in the brain of rats: a critical review.
    Myers RD; Adell A; Lankford MF
    Neurosci Biobehav Rev; 1998 May; 22(3):371-87. PubMed ID: 9579326
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Chemical gradients within brain extracellular space measured using low flow push-pull perfusion sampling in vivo.
    Slaney TR; Mabrouk OS; Porter-Stransky KA; Aragona BJ; Kennedy RT
    ACS Chem Neurosci; 2013 Feb; 4(2):321-9. PubMed ID: 23421683
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of μ-Low-Flow-Push-Pull Perfusion Probes for Ex Vivo Sampling from Mouse Hippocampal Tissue Slices.
    Cabay MR; McRay A; Featherstone DE; Shippy SA
    ACS Chem Neurosci; 2018 Feb; 9(2):252-259. PubMed ID: 29077383
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of microdialysis and push-pull perfusion for retrieval of serotonin and norepinephrine in the spinal cord dorsal horn.
    Lisi TL; Westlund KN; Sluka KA
    J Neurosci Methods; 2003 Jun; 126(2):187-94. PubMed ID: 12814843
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microfabrication and in Vivo Performance of a Microdialysis Probe with Embedded Membrane.
    Lee WH; Ngernsutivorakul T; Mabrouk OS; Wong JM; Dugan CE; Pappas SS; Yoon HJ; Kennedy RT
    Anal Chem; 2016 Jan; 88(2):1230-7. PubMed ID: 26727611
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Peristaltic versus syringe pumps for push-pull perfusion: tissue pathology and dopamine recovery in rat neostriatum.
    Privette TH; Myers RD
    J Neurosci Methods; 1989 Jan; 26(3):195-202. PubMed ID: 2918745
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical applicability of dOFM devices for dermal sampling.
    Bodenlenz M; Aigner B; Dragatin C; Liebenberger L; Zahiragic S; Höfferer C; Birngruber T; Priedl J; Feichtner F; Schaupp L; Korsatko S; Ratzer M; Magnes C; Pieber TR; Sinner F
    Skin Res Technol; 2013 Nov; 19(4):474-83. PubMed ID: 23581539
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In Vivo Chemical Monitoring at High Spatiotemporal Resolution Using Microfabricated Sampling Probes and Droplet-Based Microfluidics Coupled to Mass Spectrometry.
    Ngernsutivorakul T; Steyer DJ; Valenta AC; Kennedy RT
    Anal Chem; 2018 Sep; 90(18):10943-10950. PubMed ID: 30107117
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lower body negative pressure protects brain perfusion in aviation gravitational stress induced by push-pull manoeuvre.
    Xing C; Wang X; Gao Y; Zhang J; Liu Y; Guo Y; Wang C; Feng Y; Lei Y; Zhang X; Li J; Hu W; Zhang S; Yuan L; Gao F
    J Physiol; 2020 Aug; 598(15):3173-3186. PubMed ID: 32415785
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extracellular Fluid Collection and Analysis of
    Fisher PU; Shippy SA
    Anal Chem; 2022 Mar; 94(9):3767-3773. PubMed ID: 35201754
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modified microdialysis probe for sampling extracellular fluid and administering drugs in vivo.
    Yadid G; Pacak K; Kopin IJ; Goldstein DS
    Am J Physiol; 1993 Nov; 265(5 Pt 2):R1205-11. PubMed ID: 7902019
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A miniaturized push-pull-perfusion probe for few-second sampling of neurotransmitters in the mouse brain.
    van den Brink FTG; Phisonkunkasem T; Asthana A; Bomer JG; van den Maagdenberg AMJM; Tolner EA; Odijk M
    Lab Chip; 2019 Apr; 19(8):1332-1343. PubMed ID: 30869670
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A multipurpose four-channel fluid swivel.
    Parada MA; Puig de Parada MP; Hernandez L; Murzi E; Hoebel B
    Brain Res Bull; 1998; 45(1):117-23. PubMed ID: 9434212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Proteomic analysis and ATP assay reveal a positive effect of artificial cerebral spinal fluid perfusion following microdialysis sampling on repair of probe-induced brain damage.
    Ohyama K; Ikeshita Y; Fuchigami Y; Kawakami S; Nakashima MN; Nakashima M
    J Neurosci Methods; 2019 Mar; 315():1-5. PubMed ID: 30625339
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo monitoring of amino acids by direct sampling of brain extracellular fluid at ultralow flow rates and capillary electrophoresis.
    Kennedy RT; Thompson JE; Vickroy TW
    J Neurosci Methods; 2002 Feb; 114(1):39-49. PubMed ID: 11850038
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Negligible In Vitro Recovery of Macromolecules from Microdialysis Using 100 kDa Probes and Dextran in Perfusion Fluid.
    Dorothee S; Sørensen G; Olsen LR; Bastlund JF; Sotty F; Belling D; Olsen MH; Mathiesen TI; Møller K; Larsen F; Birkeland P
    Neurochem Res; 2024 May; 49(5):1322-1330. PubMed ID: 38478218
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.