BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

581 related articles for article (PubMed ID: 25616268)

  • 1. CT differentiation of enlarged mediastinal lymph node due to anthracosis from metastatic lymphadenopathy: a comparative study proven by endobronchial US-guided transbronchial needle aspiration.
    Kirchner J; Broll M; Müller P; Pomjanski N; Biesterfeld S; Liermann D; Kickuth R
    Diagn Interv Radiol; 2015; 21(2):128-33. PubMed ID: 25616268
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chest CT findings in EBUS-TBNA-proven anthracosis in enlarged mediastinal lymph nodes.
    Kirchner J; Mueller P; Broll M; Kirchner EM; Pomjanski N; Liermann D; Biesterfeld S; Kickuth R
    Rofo; 2014 Dec; 186(12):1122-6. PubMed ID: 24955645
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The value of endobronchial ultrasound-guided transbronchial needle aspiration, 18-fluorodeoxyglucose positron emission tomography/computed tomography, and ultrasonography imaging techniques in the diagnosis of mediastinal and/or hilar malignant, anthracotic, and other benign lymph nodes.
    Korkmaz C; Demirbas S; Vatansev H
    Medicine (Baltimore); 2021 Feb; 100(7):e24728. PubMed ID: 33607816
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnosis and subclassification of lymphomas and non-neoplastic lesions involving mediastinal lymph nodes using endobronchial ultrasound-guided transbronchial needle aspiration.
    Ko HM; da Cunha Santos G; Darling G; Pierre A; Yasufuku K; Boerner SL; Geddie WR
    Diagn Cytopathol; 2013 Dec; 41(12):1023-30. PubMed ID: 21630485
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endobronchial ultrasound-guided transbronchial needle aspiration can improve the diagnostic accuracy of positron emission tomography/computed tomography in hilar and/or mediastinal lymphadenopathy.
    Xu CC; Lei W; Jiang JH; Wang ZR; Ni CJ; Huang JA
    J Cancer Res Ther; 2019; 15(7):1490-1495. PubMed ID: 31939427
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mediastinal and Hilar Lymph Node Measurements. Comparison of Multidetector-Row Computed Tomography and Endobronchial Ultrasound.
    Udoji TN; Phillips GS; Berkowitz EA; Berkowitz D; Ross C; Bechara RI
    Ann Am Thorac Soc; 2015 Jun; 12(6):914-20. PubMed ID: 25211346
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Identification of specific EBUS sonographic characteristics for predicting benign mediastinal lymph nodes.
    Ayub II; Mohan A; Madan K; Hadda V; Jain D; Khilnani GC; Guleria R
    Clin Respir J; 2018 Feb; 12(2):681-690. PubMed ID: 27805323
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The role of endobronchial ultrasound-guided transbronchial needle aspiration in the differential diagnosis of isolated mediastinal and/or hilar lymphadenopathy.
    Temiz D; İn E; Kuluöztürk M; Kırkıl G; Artaş G; Turgut T; Deveci F
    Diagn Cytopathol; 2021 Sep; 49(9):1012-1021. PubMed ID: 34078002
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endobronchial ultrasound-guided transbronchial needle aspiration for the diagnosis of intrathoracic lymphadenopathy in patients with extrathoracic malignancy: A study in a tuberculosis-endemic country.
    Ozgül MA; Cetinkaya E; Tutar N; Ozgül G; Onaran H; Bilaceroglu S
    J Cancer Res Ther; 2013; 9(3):416-21. PubMed ID: 24125976
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk factors and maximum standardized uptake values within lymph nodes of anthracosis diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration.
    Yilmaz Demirci N; Alici IO; Yilmaz A; Demirağ F; Tatci E; Erdoğan Y
    Turk J Med Sci; 2015; 45(4):984-90. PubMed ID: 26422878
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The utility of elastography during EBUS-TBNA in a population with a high prevalence of anthracosis.
    Abedini A; Razavi F; Farahani M; Hashemi M; Emami H; Mohammadi F; Kiani A
    Clin Respir J; 2020 May; 14(5):488-494. PubMed ID: 32034995
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically and positron emission tomography-normal mediastinum in patients with lung cancer.
    Herth FJ; Eberhardt R; Krasnik M; Ernst A
    Chest; 2008 Apr; 133(4):887-91. PubMed ID: 18263680
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Utility of the Ultrasonographic Characteristics in Differentiating Between Malignant and Tuberculous Mediastinal Lymphadenopathy During EBUS-TBNA.
    Madan K; Madan M; Mittal S; Tiwari P; Hadda V; Mohan A; Pandey RM; Guleria R
    J Bronchology Interv Pulmonol; 2023 Jan; 30(1):47-53. PubMed ID: 35361744
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endobronchial ultrasound-guided transbronchial needle aspiration in diagnosing intrathoracic tuberculosis.
    Sun J; Teng J; Yang H; Li Z; Zhang J; Zhao H; Garfield DH; Han B
    Ann Thorac Surg; 2013 Dec; 96(6):2021-7. PubMed ID: 24035300
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The evaluation of lymph node metastasis by endobronchial ultrasound-guided transbronchial needle aspiration: crucial for selection of surgical candidates with metastatic lung tumors.
    Nakajima T; Yasufuku K; Iyoda A; Yoshida S; Suzuki M; Sekine Y; Shibuya K; Hiroshima K; Nakatani Y; Fujisawa T
    J Thorac Cardiovasc Surg; 2007 Dec; 134(6):1485-90. PubMed ID: 18023670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sensitivity of linear endobronchial ultrasonography and guided transbronchial needle aspiration for the identification of nodal metastasis in lung cancer staging.
    Garcia-Olivé I; Monsó E; Andreo F; Sanz J; Castellà E; Llatjós M; de Miguel E; Astudillo J
    Ultrasound Med Biol; 2009 Aug; 35(8):1271-7. PubMed ID: 19540652
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endobronchial ultrasound-guided needle aspiration of mediastinal adenopathy.
    Shannon JJ; Bude RO; Orens JB; Becker FS; Whyte RI; Rubin JM; Quint LE; Martinez FJ
    Am J Respir Crit Care Med; 1996 Apr; 153(4 Pt 1):1424-30. PubMed ID: 8616576
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endobronchial Ultrasound in Suspected Non-Malignant Mediastinal Lymphadenopathy.
    Eickhoff L; Golpon H; Zardo P; Suhling H; Welte T; Jonigk D; Gottlieb J; Fuehner T
    Pneumologie; 2018 Aug; 72(8):559-567. PubMed ID: 29788514
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized controlled trial to evaluate the utility of suction and inner-stylet of EBUS-TBNA for mediastinal and hilar lymphadenopathy.
    Lin X; Ye M; Li Y; Ren J; Lou Q; Li Y; Jin X; Wang KP; Chen C
    BMC Pulm Med; 2018 Dec; 18(1):192. PubMed ID: 30526587
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lymph node staging by endobronchial ultrasound-guided transbronchial needle aspiration in patients with small cell lung cancer.
    Wada H; Nakajima T; Yasufuku K; Fujiwara T; Yoshida S; Suzuki M; Shibuya K; Hiroshima K; Nakatani Y; Yoshino I
    Ann Thorac Surg; 2010 Jul; 90(1):229-34. PubMed ID: 20609781
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 30.