These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 25621691)

  • 1. Repeatability of blood gas parameters, PCO2 gap, and PCO2 gap to arterial-to-venous oxygen content difference in critically ill adult patients.
    Mallat J; Lazkani A; Lemyze M; Pepy F; Meddour M; Gasan G; Temime J; Vangrunderbeeck N; Tronchon L; Thevenin D
    Medicine (Baltimore); 2015 Jan; 94(3):e415. PubMed ID: 25621691
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of time delay and body temperature on measurements of central venous oxygen saturation, venous-arterial blood carbon dioxide partial pressures difference, venous-arterial blood carbon dioxide partial pressures difference/arterial-venous oxygen difference ratio and lactate.
    Wan XY; Wei LL; Jiang Y; Li P; Yao B
    BMC Anesthesiol; 2018 Dec; 18(1):187. PubMed ID: 30537939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The ratios of central venous to arterial carbon dioxide content and tension to arteriovenous oxygen content are not associated with overall anaerobic metabolism in postoperative cardiac surgery patients.
    Abou-Arab O; Braik R; Huette P; Bouhemad B; Lorne E; Guinot PG
    PLoS One; 2018; 13(10):e0205950. PubMed ID: 30365515
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing Central Venous Blood Gas to Arterial Blood Gas and Determining Its Utility in Critically Ill Patients: Narrative Review.
    Chong WH; Saha BK; Medarov BI
    Anesth Analg; 2021 Aug; 133(2):374-378. PubMed ID: 33780397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The repeatability of Stewart's parameters and anion gap in a cohort of critically ill adult patients.
    Mallat J; Barrailler S; Lemyze M; Benzidi Y; Pepy F; Gasan G; Tronchon L; Thevenin D
    Intensive Care Med; 2012 Dec; 38(12):2026-31. PubMed ID: 22926652
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Central Venous-to-Arterial PCO2 Difference and Central Venous Oxygen Saturation in the Detection of Extubation Failure in Critically Ill Patients.
    Mallat J; Baghdadi FA; Mohammad U; Lemyze M; Temime J; Tronchon L; Thevenin D; Fischer MO
    Crit Care Med; 2020 Oct; 48(10):1454-1461. PubMed ID: 32520890
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The oxygen status of the arterial blood in the critically ill.
    Tulli G; Vignali G; Guadagnucci A; Mondello V
    Scand J Clin Lab Invest Suppl; 1990; 203():107-18. PubMed ID: 2128553
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Poor agreement in the calculation of venoarterial PCO
    Dubin A; Pozo MO; Kanoore Edul VS; Risso Vazquez A; Enrico C
    J Crit Care; 2018 Dec; 48():445-450. PubMed ID: 30409351
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Central venous O₂ saturation and venous-to-arterial CO₂ difference as complementary tools for goal-directed therapy during high-risk surgery.
    Futier E; Robin E; Jabaudon M; Guerin R; Petit A; Bazin JE; Constantin JM; Vallet B
    Crit Care; 2010; 14(5):R193. PubMed ID: 21034476
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of arterial dissolved oxygen level on venous oxygen saturation: don't forget the PaO2!
    Legrand M; Vallée F; Mateo J; Payen D
    Shock; 2014 Jun; 41(6):510-3. PubMed ID: 24667613
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Central venous-to-arterial carbon dioxide difference and the effect of venous hyperoxia: A limiting factor, or an additional marker of severity in shock?
    Saludes P; Proença L; Gruartmoner G; Enseñat L; Pérez-Madrigal A; Espinal C; Mesquida J
    J Clin Monit Comput; 2017 Dec; 31(6):1203-1211. PubMed ID: 27832407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.
    Du W; Liu DW; Wang XT; Long Y; Chai WZ; Zhou X; Rui X
    J Crit Care; 2013 Dec; 28(6):1110.e1-5. PubMed ID: 24216336
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Time course of central venous-to-arterial carbon dioxide tension difference in septic shock patients receiving incremental doses of dobutamine.
    Mallat J; Benzidi Y; Salleron J; Lemyze M; Gasan G; Vangrunderbeeck N; Pepy F; Tronchon L; Vallet B; Thevenin D
    Intensive Care Med; 2014 Mar; 40(3):404-11. PubMed ID: 24306082
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acute hyperventilation increases oxygen consumption and decreases peripheral tissue perfusion in critically ill patients.
    Zhou Y; He H; Cui N; Wang H; Zhou X; Long Y
    J Crit Care; 2021 Dec; 66():148-153. PubMed ID: 34364716
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Central venous-to-arterial carbon dioxide difference combined with arterial-to-venous oxygen content difference is associated with lactate evolution in the hemodynamic resuscitation process in early septic shock.
    Mesquida J; Saludes P; Gruartmoner G; Espinal C; Torrents E; Baigorri F; Artigas A
    Crit Care; 2015 Mar; 19(1):126. PubMed ID: 25888382
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical predictors of a low central venous oxygen saturation after major surgery: a prospective prevalence study.
    Litton E; Silbert B; Ho KM
    Anaesth Intensive Care; 2015 Jan; 43(1):59-65. PubMed ID: 25579290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders.
    Monnet X; Julien F; Ait-Hamou N; Lequoy M; Gosset C; Jozwiak M; Persichini R; Anguel N; Richard C; Teboul JL
    Crit Care Med; 2013 Jun; 41(6):1412-20. PubMed ID: 23442986
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measuring oxygen uptake and carbon dioxide production in critically ill patients using a standard blood gas analyzer.
    Zenger M; Brenner M; Hua P; Haruno M; Wilson AF
    Crit Care Med; 1994 May; 22(5):783-8. PubMed ID: 8181286
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous arterial and venous blood gas monitoring during cardiopulmonary bypass.
    Mark JB; FitzGerald D; Fenton T; Fosberg AM; Camann W; Maffeo N; Winkelman J
    J Thorac Cardiovasc Surg; 1991 Sep; 102(3):431-9. PubMed ID: 1908928
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Central venous-to-arterial carbon dioxide difference as a prognostic tool in high-risk surgical patients.
    Robin E; Futier E; Pires O; Fleyfel M; Tavernier B; Lebuffe G; Vallet B
    Crit Care; 2015 May; 19(1):227. PubMed ID: 25967737
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.