BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 25625696)

  • 1. Magnetically steerable gastric capsule endoscopy is equivalent to flexible endoscopy in the detection of markers in an excised porcine stomach model: results of a randomized trial.
    Hale MF; Rahman I; Drew K; Sidhu R; Riley SA; Patel P; McAlindon ME
    Endoscopy; 2015 Jul; 47(7):650-3. PubMed ID: 25625696
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fully automated magnetically controlled capsule endoscopy for examination of the stomach and small bowel: a prospective, feasibility, two-centre study.
    Xiao YF; Wu ZX; He S; Zhou YY; Zhao YB; He JL; Peng X; Yang ZX; Lv QJ; Yang H; Bai JY; Fan CQ; Tang B; Hu CJ; Jie MM; Liu E; Lin H; Koulaouzidis A; Zhao XY; Yang SM; Xie X
    Lancet Gastroenterol Hepatol; 2021 Nov; 6(11):914-921. PubMed ID: 34555347
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetically guided capsule versus conventional gastroscopy for upper abdominal complaints: a prospective blinded study.
    Denzer UW; Rösch T; Hoytat B; Abdel-Hamid M; Hebuterne X; Vanbiervielt G; Filippi J; Ogata H; Hosoe N; Ohtsuka K; Ogata N; Ikeda K; Aihara H; Kudo SE; Tajiri H; Treszl A; Wegscheider K; Greff M; Rey JF
    J Clin Gastroenterol; 2015 Feb; 49(2):101-7. PubMed ID: 24618504
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of Magnetically Controlled Capsule Endoscopy, Compared With Conventional Gastroscopy, in Detection of Gastric Diseases.
    Liao Z; Hou X; Lin-Hu EQ; Sheng JQ; Ge ZZ; Jiang B; Hou XH; Liu JY; Li Z; Huang QY; Zhao XJ; Li N; Gao YJ; Zhang Y; Zhou JQ; Wang XY; Liu J; Xie XP; Yang CM; Liu HL; Sun XT; Zou WB; Li ZS
    Clin Gastroenterol Hepatol; 2016 Sep; 14(9):1266-1273.e1. PubMed ID: 27211503
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers (with videos).
    Keller J; Fibbe C; Volke F; Gerber J; Mosse AC; Reimann-Zawadzki M; Rabinovitz E; Layer P; Schmitt D; Andresen V; Rosien U; Swain P
    Gastrointest Endosc; 2011 Jan; 73(1):22-8. PubMed ID: 21067740
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Human gastric magnet-controlled capsule endoscopy conducted in a standing position: the phase 1 study.
    Cheng CS; Sun TJ; Zhang HD
    BMC Gastroenterol; 2019 Nov; 19(1):184. PubMed ID: 31718547
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic control system targeted for capsule endoscopic operations in the stomach--design, fabrication, and in vitro and ex vivo evaluations.
    Lien GS; Liu CW; Jiang JA; Chuang CL; Teng MT
    IEEE Trans Biomed Eng; 2012 Jul; 59(7):2068-79. PubMed ID: 22581127
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnetic-assisted capsule endoscopy in the upper GI tract by using a novel navigation system (with video).
    Rahman I; Pioche M; Shim CS; Lee SP; Sung IK; Saurin JC; Patel P
    Gastrointest Endosc; 2016 May; 83(5):889-895.e1. PubMed ID: 26405045
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Gastric examination using a novel three-dimensional magnetically assisted capsule endoscope and a hand-held magnetic controller: A porcine model study.
    Oh DJ; Nam JH; Park J; Hwang Y; Lim YJ
    PLoS One; 2021; 16(10):e0256519. PubMed ID: 34610019
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Standing-type magnetically guided capsule endoscopy versus gastroscopy for gastric examination: multicenter blinded comparative trial.
    Lai HS; Wang XK; Cai JQ; Zhao XM; Han ZL; Zhang J; Chen ZY; Lin ZZ; Zhou PH; Hu B; Li AM; Liu SD
    Dig Endosc; 2020 May; 32(4):557-564. PubMed ID: 31483889
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope.
    Rey JF; Ogata H; Hosoe N; Ohtsuka K; Ogata N; Ikeda K; Aihara H; Pangtay I; Hibi T; Kudo SE; Tajiri H
    Gastrointest Endosc; 2012 Feb; 75(2):373-81. PubMed ID: 22154417
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Feasibility and safety of magnetically guided capsule endoscopy in minors].
    Xie MP; Wang LF; Cheng SD; Shen RZ
    Zhonghua Wei Chang Wai Ke Za Zhi; 2019 Jul; 22(7):662-667. PubMed ID: 31302965
    [No Abstract]   [Full Text] [Related]  

  • 13. Impact of magnetic steering on gastric transit time of a capsule endoscopy (with video).
    Jiang X; Qian YY; Liu X; Pan J; Zou WB; Zhou W; Luo YY; Chen YZ; Li ZS; Liao Z
    Gastrointest Endosc; 2018 Oct; 88(4):746-754. PubMed ID: 30005825
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Repetitive Position Change Improves Gastric Cleanliness for Magnetically Controlled Capsule Gastroscopy.
    Wang YC; Pan J; Jiang X; Su XJ; Zhou W; Zou WB; Qian YY; Chen YZ; Liu X; Yu J; Yan XN; Zhao AJ; Li ZS; Liao Z
    Dig Dis Sci; 2019 May; 64(5):1297-1304. PubMed ID: 30560329
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetically Controlled Capsule Endoscopy Versus Conventional Gastroscopy: A Systematic Review and Meta-Analysis.
    Geropoulos G; Aquilina J; Kakos C; Anestiadou E; Giannis D
    J Clin Gastroenterol; 2021 Aug; 55(7):577-585. PubMed ID: 33883514
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endoscopic submucosal dissection with a novel traction method using a steerable grasper: a feasibility study in a porcine model.
    Chung H; Dhumane P; Liu KH; Donatelli G; Dallemagne B; Marescaux J
    Surg Innov; 2014 Feb; 21(1):5-10. PubMed ID: 23938360
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetic-controlled capsule endoscopy vs. gastroscopy for gastric diseases: a two-center self-controlled comparative trial.
    Zou WB; Hou XH; Xin L; Liu J; Bo LM; Yu GY; Liao Z; Li ZS
    Endoscopy; 2015 Jun; 47(6):525-8. PubMed ID: 25590177
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetic Steering of Capsule Endoscopy Improves Small Bowel Capsule Endoscopy Completion Rate.
    Luo YY; Pan J; Chen YZ; Jiang X; Zou WB; Qian YY; Zhou W; Liu X; Li ZS; Liao Z
    Dig Dis Sci; 2019 Jul; 64(7):1908-1915. PubMed ID: 30725289
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility proof of a legged locomotion capsule for the GI tract.
    Quirini M; Menciassi A; Scapellato S; Dario P; Rieber F; Ho CN; Schostek S; Schurr MO
    Gastrointest Endosc; 2008 Jun; 67(7):1153-8. PubMed ID: 18513557
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications.
    Valdastri P; Quaglia C; Buselli E; Arezzo A; Di Lorenzo N; Morino M; Menciassi A; Dario P
    Endoscopy; 2010 Jun; 42(6):481-6. PubMed ID: 20506065
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.