These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
147 related articles for article (PubMed ID: 25631202)
1. Local Quantification of Wall Thickness and Intraluminal Thrombus Offer Insight into the Mechanical Properties of the Aneurysmal Aorta. Martufi G; Satriano A; Moore RD; Vorp DA; Di Martino ES Ann Biomed Eng; 2015 Aug; 43(8):1759-71. PubMed ID: 25631202 [TBL] [Abstract][Full Text] [Related]
2. The quasi-static failure properties of the abdominal aortic aneurysm wall estimated by a mixed experimental-numerical approach. Forsell C; Swedenborg J; Roy J; Gasser TC Ann Biomed Eng; 2013 Jul; 41(7):1554-66. PubMed ID: 23263935 [TBL] [Abstract][Full Text] [Related]
3. Effects of age on the elastic properties of the intraluminal thrombus and the thrombus-covered wall in abdominal aortic aneurysms: biaxial extension behaviour and material modelling. Tong J; Cohnert T; Regitnig P; Holzapfel GA Eur J Vasc Endovasc Surg; 2011 Aug; 42(2):207-19. PubMed ID: 21440466 [TBL] [Abstract][Full Text] [Related]
4. Correlation of Intraluminal Thrombus Deposition, Biomechanics, and Hemodynamics with Surface Growth and Rupture in Abdominal Aortic Aneurysm-Application in a Clinical Paradigm. Metaxa E; Tzirakis K; Kontopodis N; Ioannou CV; Papaharilaou Y Ann Vasc Surg; 2018 Jan; 46():357-366. PubMed ID: 28887252 [TBL] [Abstract][Full Text] [Related]
5. Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress. Mower WR; Quiñones WJ; Gambhir SS J Vasc Surg; 1997 Oct; 26(4):602-8. PubMed ID: 9357460 [TBL] [Abstract][Full Text] [Related]
6. Failure properties of intraluminal thrombus in abdominal aortic aneurysm under static and pulsating mechanical loads. Gasser TC; Görgülü G; Folkesson M; Swedenborg J J Vasc Surg; 2008 Jul; 48(1):179-88. PubMed ID: 18486417 [TBL] [Abstract][Full Text] [Related]
7. Impact of calcification and intraluminal thrombus on the computed wall stresses of abdominal aortic aneurysm. Li ZY; U-King-Im J; Tang TY; Soh E; See TC; Gillard JH J Vasc Surg; 2008 May; 47(5):928-35. PubMed ID: 18372154 [TBL] [Abstract][Full Text] [Related]
15. Histologic, histochemical, and biomechanical properties of fragments isolated from the anterior wall of abdominal aortic aneurysms. Tavares Monteiro JA; da Silva ES; Raghavan ML; Puech-Leão P; de Lourdes Higuchi M; Otoch JP J Vasc Surg; 2014 May; 59(5):1393-401.e1-2. PubMed ID: 23891493 [TBL] [Abstract][Full Text] [Related]
16. Effect of variation in intraluminal thrombus constitutive properties on abdominal aortic aneurysm wall stress. Di Martino ES; Vorp DA Ann Biomed Eng; 2003; 31(7):804-9. PubMed ID: 12971613 [TBL] [Abstract][Full Text] [Related]
17. The impact of intraluminal thrombus failure on the mechanical stress in the wall of abdominal aortic aneurysms. Polzer S; Gasser TC; Swedenborg J; Bursa J Eur J Vasc Endovasc Surg; 2011 Apr; 41(4):467-73. PubMed ID: 21269846 [TBL] [Abstract][Full Text] [Related]
18. Local Diameter, Wall Stress, and Thrombus Thickness Influence the Local Growth of Abdominal Aortic Aneurysms. Martufi G; Lindquist Liljeqvist M; Sakalihasan N; Panuccio G; Hultgren R; Roy J; Gasser TC J Endovasc Ther; 2016 Dec; 23(6):957-966. PubMed ID: 27412646 [TBL] [Abstract][Full Text] [Related]
19. Measuring and modeling patient-specific distributions of material properties in abdominal aortic aneurysm wall. Reeps C; Maier A; Pelisek J; Härtl F; Grabher-Meier V; Wall WA; Essler M; Eckstein HH; Gee MW Biomech Model Mechanobiol; 2013 Aug; 12(4):717-33. PubMed ID: 22955570 [TBL] [Abstract][Full Text] [Related]
20. Intraluminal thrombus thickness is not related to lower concentrations of trace elements in the wall of infrarenal abdominal aortic aneurysms. Ziaja D; Kita A; Janowska J; Pawlicki K; Mikuła B; Sznapka M; Chudek J; Ziaja K J Trace Elem Med Biol; 2014 Jan; 28(1):28-31. PubMed ID: 24220057 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]