These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 25633163)

  • 1. Evaluation of the accuracy of a veterinary dynamometric wire tensioner.
    Gauthier CM; McGilvray K; Myrick S; Duerr F; Palmer R
    Vet Comp Orthop Traumatol; 2015; 28(2):104-8. PubMed ID: 25633163
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The accuracy of fine wire tensioners: a comparison of five tensioners used in hybrid and ring external fixation.
    Roberts CS; Antoci V; Antoci V; Voor MJ
    J Orthop Trauma; 2004 Mar; 18(3):158-62. PubMed ID: 15091270
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reduction in wire tension caused by wire clamping and wire tensioner removal: an experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    Proc Inst Mech Eng H; 2011 Mar; 225(3):220-7. PubMed ID: 21485324
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Axial characteristics of circular external skeletal fixator single ring constructs.
    Lewis DD; Bronson DG; Cross AR; Welch RD; Kubilis PS
    Vet Surg; 2001; 30(4):386-94. PubMed ID: 11443601
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of ring diameter and wire tension on the axial biomechanics of four-ring circular external skeletal fixator constructs.
    Cross AR; Lewis DD; Murphy ST; Rigaud S; Madison JB; Kehoe MM; Rapoff AJ
    Am J Vet Res; 2001 Jul; 62(7):1025-30. PubMed ID: 11453475
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reduction in wire tension caused by dynamic loading. An experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    J Biomech; 2011 May; 44(8):1454-8. PubMed ID: 21453923
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Axial stiffness and ring deformation of complete and incomplete single ring circular external skeletal fixator constructs.
    Hudson CC; Lewis DD; Cross AR; Horodyski M; Banks SA; Pozzi A
    Am J Vet Res; 2012 Dec; 73(12):2021-8. PubMed ID: 23176434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Wire tension in the Ilizarov system: accuracy of the wire-tensioning device.
    Watson MA; Mathias KJ; Ashcroft GP; Maffulli N; Hukins DW; Shepherd DE
    Proc Inst Mech Eng H; 2005 Sep; 219(5):355-9. PubMed ID: 16225152
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanics of olive wire positioning and tensioning characteristics.
    Antoci V; Voor MJ; Antoci V; Roberts CS
    J Pediatr Orthop; 2005; 25(6):798-803. PubMed ID: 16294139
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Yielding of the clamped-wire system in the Ilizarov external fixator.
    Watson MA; Matthias KJ; Maffulli N; Hukins DW
    Proc Inst Mech Eng H; 2003; 217(5):367-74. PubMed ID: 14558649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid pre-tension loss in the Ilizarov external fixator: an in vitro study.
    Aquarius R; Van Kampen A; Verdonschot N
    Acta Orthop; 2007 Oct; 78(5):654-60. PubMed ID: 17966025
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.
    Watson MA; Mathias KJ; Maffulli N; Hukins DW
    Proc Inst Mech Eng H; 2003; 217(2):91-8. PubMed ID: 12666775
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of wire tension on stiffness of tensioned fine wires in external fixation: a mechanical study.
    Antoci V; Voor MJ; Antoci V; Roberts CS
    Am J Orthop (Belle Mead NJ); 2007 Sep; 36(9):473-6. PubMed ID: 17948150
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ilizarov wire tensioning and holding methods: a biomechanical study.
    Davidson AW; Mullins M; Goodier D; Barry M
    Injury; 2003 Feb; 34(2):151-4. PubMed ID: 12565024
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Wire tension versus wire frequency: an experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    J Biomech; 2010 Aug; 43(12):2327-31. PubMed ID: 20472242
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous anterior and posterior compression of the pelvic ring with external fixation using a pre-tensed curved bar: A biomechanical study.
    Queipo-de-Llano A; Perez-Blanca A; Ezquerro F; Luna-González F
    Injury; 2013 Dec; 44(12):1787-92. PubMed ID: 24016457
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanical stress on tensioned wires at direct and indirect loading: a biomechanical study on the Ilizarov external fixator.
    Gessmann J; Jettkant B; Schildhauer TA; Seybold D
    Injury; 2011 Oct; 42(10):1107-11. PubMed ID: 21392761
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical evaluation of transosseous wire rope configurations in a large animal external fixator.
    Rapoff AJ; Markel MD; Vanderby R
    Am J Vet Res; 1995 May; 56(5):694-9. PubMed ID: 7661467
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Geometric and material nonlinearity in tensioned wires of an external fixator.
    Zhang G
    Clin Biomech (Bristol, Avon); 2004 Jun; 19(5):513-8. PubMed ID: 15182987
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relationship between locking-bolt torque and load pre-tension in the Ilizarov frame.
    Osei NA; Bradley BM; Culpan P; Mitchell JB; Barry M; Tanner KE
    Injury; 2006 Oct; 37(10):941-5. PubMed ID: 16769071
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.