232 related articles for article (PubMed ID: 25634138)
1. HAp/Ti2Ni coatings of high bonding strength on Ti-6Al-4V prepared by the eutectic melting bonding method.
Ye YJ; Wang PY; Li YP; Yin DC
J Mater Sci Mater Med; 2015 Feb; 26(2):81. PubMed ID: 25634138
[TBL] [Abstract][Full Text] [Related]
2. Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method.
Wu C; Ramaswamy Y; Gale D; Yang W; Xiao K; Zhang L; Yin Y; Zreiqat H
Acta Biomater; 2008 May; 4(3):569-76. PubMed ID: 18182336
[TBL] [Abstract][Full Text] [Related]
3. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti-6Al-4V composite coatings.
Khor KA; Gu YW; Pan D; Cheang P
Biomaterials; 2004 Aug; 25(18):4009-17. PubMed ID: 15046891
[TBL] [Abstract][Full Text] [Related]
4. Structure, phases, and mechanical response of Ti-alloy bioactive glass composite coatings.
Nelson GM; Nychka JA; McDonald AG
Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():261-76. PubMed ID: 24433912
[TBL] [Abstract][Full Text] [Related]
5. Preparation and in vitro evaluation of plasma-sprayed bioactive akermanite coatings.
Yi D; Wu C; Ma X; Ji H; Zheng X; Chang J
Biomed Mater; 2012 Dec; 7(6):065004. PubMed ID: 23159958
[TBL] [Abstract][Full Text] [Related]
6. Characterization of hydroxyapatite and titanium coatings sputtered on Ti-6Al-4V substrate.
Ding SJ; Ju CP; Lin JH
J Biomed Mater Res; 1999 Mar; 44(3):266-79. PubMed ID: 10397929
[TBL] [Abstract][Full Text] [Related]
7. Crystallographic characteristics of plasma-sprayed calcium phosphate coatings on Ti-6Al-4V.
Tufekci E; Brantley WA; Mitchell JC; Foreman DW; Georgette FS
Int J Oral Maxillofac Implants; 1999; 14(5):661-72. PubMed ID: 10531738
[TBL] [Abstract][Full Text] [Related]
8. Comparative assessment of structural and biological properties of biomimetically coated hydroxyapatite on alumina (alpha-Al2O3) and titanium (Ti-6Al-4V) alloy substrates.
Kapoor R; Sistla PG; Kumar JM; Raj TA; Srinivas G; Chakraborty J; Sinha MK; Basu D; Pande G
J Biomed Mater Res A; 2010 Sep; 94(3):913-26. PubMed ID: 20730928
[TBL] [Abstract][Full Text] [Related]
9. Activity of plasma sprayed yttria stabilized zirconia reinforced hydroxyapatite/Ti-6Al-4V composite coatings in simulated body fluid.
Gu YW; Khor KA; Pan D; Cheang P
Biomaterials; 2004 Jul; 25(16):3177-85. PubMed ID: 14980413
[TBL] [Abstract][Full Text] [Related]
10. An in vitro investigation of plasma sprayed hydroxyapatite (HA) coatings produced with flame-spheroidized feedstock.
Kweh SW; Khor KA; Cheang P
Biomaterials; 2002 Feb; 23(3):775-85. PubMed ID: 11774849
[TBL] [Abstract][Full Text] [Related]
11. Bond strength of plasma-sprayed hydroxyapatite/Ti composite coatings.
Zheng X; Huang M; Ding C
Biomaterials; 2000 Apr; 21(8):841-9. PubMed ID: 10721753
[TBL] [Abstract][Full Text] [Related]
12. Improved bonding strength of bioactive cermet Cold Gas Spray coatings.
Gardon M; Concustell A; Dosta S; Cinca N; Cano IG; Guilemany JM
Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():117-21. PubMed ID: 25491809
[TBL] [Abstract][Full Text] [Related]
13. Bond strength determination of hydroxyapatite coatings on Ti-6Al-4V substrates using the LAser Shock Adhesion Test (LASAT).
Guipont V; Jeandin M; Bansard S; Khor KA; Nivard M; Berthe L; Cuq-Lelandais JP; Boustie M
J Biomed Mater Res A; 2010 Dec; 95(4):1096-104. PubMed ID: 20878900
[TBL] [Abstract][Full Text] [Related]
14. Microstructures, hardness and bioactivity of hydroxyapatite coatings deposited by direct laser melting process.
Tlotleng M; Akinlabi E; Shukla M; Pityana S
Mater Sci Eng C Mater Biol Appl; 2014 Oct; 43():189-98. PubMed ID: 25175204
[TBL] [Abstract][Full Text] [Related]
15. Influence of residual stress on bonding strength and fracture of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V substrate.
Yang YC; Chang E
Biomaterials; 2001 Jul; 22(13):1827-36. PubMed ID: 11396887
[TBL] [Abstract][Full Text] [Related]
16. Microstructure and corrosion behavior of porous coatings on titanium alloy by vacuum-brazed method.
Lee TM; Chang E; Yen CH
J Biomed Mater Res B Appl Biomater; 2006 May; 77(2):369-77. PubMed ID: 16278850
[TBL] [Abstract][Full Text] [Related]
17. In vitro biological response of plasma electrolytically oxidized and plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V alloy.
Yeung WK; Reilly GC; Matthews A; Yerokhin A
J Biomed Mater Res B Appl Biomater; 2013 Aug; 101(6):939-49. PubMed ID: 23529912
[TBL] [Abstract][Full Text] [Related]
18. Axial Suspension Plasma Spraying: An ultimate technique to tailor Ti6Al4V surface with HAp for orthopaedic applications.
Hameed P; Gopal V; Bjorklund S; Ganvir A; Sen D; Markocsan N; Manivasagam G
Colloids Surf B Biointerfaces; 2019 Jan; 173():806-815. PubMed ID: 30551296
[TBL] [Abstract][Full Text] [Related]
19. Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 1: Mechanical properties and residual stress levels.
Tsui YC; Doyle C; Clyne TW
Biomaterials; 1998 Nov; 19(22):2015-29. PubMed ID: 9870753
[TBL] [Abstract][Full Text] [Related]
20. Bond strength, compositional, and structural properties of hydroxyapatite coating on Ti, ZrO2-coated Ti, and TPS-coated Ti substrate.
Yang Y; Ong JL
J Biomed Mater Res A; 2003 Mar; 64(3):509-16. PubMed ID: 12579565
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]