BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 25634195)

  • 1. 3-L split-dose is superior to 2-L polyethylene glycol in bowel cleansing in Chinese population: a multicenter randomized, controlled trial.
    Zhang S; Li M; Zhao Y; Lv T; Shu Q; Zhi F; Cui Y; Chen M
    Medicine (Baltimore); 2015 Jan; 94(4):e472. PubMed ID: 25634195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial.
    Zhang S; Zheng D; Wang J; Wu J; Lei P; Luo Q; Wang L; Zhang B; Wang H; Cui Y; Chen M
    Endoscopy; 2018 Apr; 50(4):412-422. PubMed ID: 29132175
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy and safety of split-dose bowel preparation with 1 L polyethylene glycol and ascorbate compared with 2 L polyethylene glycol and ascorbate in a Korean population: a phase IV, multicenter, randomized, endoscopist-blinded study.
    Hong SN; Lee CK; Im JP; Choi CH; Byeon JS; Cho YS; Jung SA; Kim TI; Jeen YT
    Gastrointest Endosc; 2022 Mar; 95(3):500-511.e2. PubMed ID: 34653425
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Two Intensive Bowel Cleansing Regimens in Patients With Previous Poor Bowel Preparation: A Randomized Controlled Study.
    Gimeno-García AZ; Hernandez G; Aldea A; Nicolás-Pérez D; Jiménez A; Carrillo M; Felipe V; Alarcón-Fernández O; Hernandez-Guerra M; Romero R; Alonso I; Gonzalez Y; Adrian Z; Moreno M; Ramos L; Quintero E
    Am J Gastroenterol; 2017 Jun; 112(6):951-958. PubMed ID: 28291237
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation.
    Parente F; Vailati C; Bargiggia S; Manes G; Fontana P; Masci E; Arena M; Spinzi G; Baccarin A; Mazzoleni G; Testoni PA
    Dig Liver Dis; 2015 Oct; 47(10):857-63. PubMed ID: 26232311
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Multicenter Randomized Controlled Trial Comparing Two Bowel Cleansing Regimens for Colonoscopy After Failed Bowel Preparation.
    Sey MSL; Von Renteln D; Sultanian R; McDonald C; Bouin M; Chande N; Sandhu A; Yan B; Martel M; Barkun A
    Clin Gastroenterol Hepatol; 2022 Jun; 20(6):e1283-e1291. PubMed ID: 34256147
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low-volume morning-only polyethylene glycol with specially designed test meals versus standard-volume split-dose polyethylene glycol with standard diet for colonoscopy: a prospective, randomized trial.
    Seo EH; Kim TO; Park MJ; Heo NY; Park J; Yang SY
    Digestion; 2013; 88(2):110-8. PubMed ID: 23949563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A single or split dose picosulphate/magnesium citrate before colonoscopy: comparison regarding tolerance and efficacy with polyethylene glycol. A randomized trial.
    Kojecky V; Dolina J; Kianicka B; Misurec M; Varga M; Latta J; Vaculin V
    J Gastrointestin Liver Dis; 2014 Jun; 23(2):141-6. PubMed ID: 24949605
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy of morning-only 4 liter sulfa free polyethylene glycol vs 2 liter polyethylene glycol with ascorbic acid for afternoon colonoscopy.
    Rivas JM; Perez A; Hernandez M; Schneider A; Castro FJ
    World J Gastroenterol; 2014 Aug; 20(30):10620-7. PubMed ID: 25132784
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Low-Volume Polyethylene Glycol with Ascorbic Acid for Colonoscopy Preparation in Elderly Patients: A Randomized Multicenter Study.
    Jung YS; Lee CK; Eun CS; Park DI; Han DS; Kim HJ
    Digestion; 2016; 94(2):82-91. PubMed ID: 27553205
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effectiveness of very low-volume preparation for colonoscopy: A prospective, multicenter observational study.
    Maida M; Sinagra E; Morreale GC; Sferrazza S; Scalisi G; Schillaci D; Ventimiglia M; Macaluso FS; Vettori G; Conoscenti G; Di Bartolo C; Garufi S; Catarella D; Manganaro M; Virgilio CM; Camilleri S
    World J Gastroenterol; 2020 Apr; 26(16):1950-1961. PubMed ID: 32390705
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy of Polyethylene Glycol Electrolyte Powder Combined With Linaclotide for Colon Cleansing in Patients With Chronic Constipation Undergoing Colonoscopy: A Multicenter, Single-Blinded, Randomized Controlled Trial.
    Wang L; Zhang Y; Li J; Ran Y; Wang X; Ma X; Yang Q; Wang F; Hu J; Zhuang K; Wang J; Quan X; Wang S; Meng R; Chen Y; Li X; Song Y; Han S; Hu H; Li L; Dai F
    Clin Transl Gastroenterol; 2024 Jun; 15(6):e1. PubMed ID: 38713137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inadequate Bowel Cleansing Efficacy of Split-dose Polyethylene Glycol for Colonoscopy in Type 2 Diabetic Patients: A Prospective and Blinded Study.
    Kim YH; Seo EH; Lee JS; Lee SH; Park HS; Choi SH; Park JY; Lee CW
    J Clin Gastroenterol; 2017 Mar; 51(3):240-246. PubMed ID: 27136960
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Randomized controlled trial of sodium phosphate tablets vs polyethylene glycol solution for colonoscopy bowel cleansing.
    Jung YS; Lee CK; Kim HJ; Eun CS; Han DS; Park DI
    World J Gastroenterol; 2014 Nov; 20(42):15845-51. PubMed ID: 25400471
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II study.
    Katz PO; Rex DK; Epstein M; Grandhi NK; Vanner S; Hookey LC; Alderfer V; Joseph RE
    Am J Gastroenterol; 2013 Mar; 108(3):401-9. PubMed ID: 23318484
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel ultra-low-volume regimen combining 1 L polyethylene glycol and linaclotide versus 2 L polyethylene glycol for colonoscopy cleansing in low-risk individuals: a randomized controlled trial.
    Zhang C; Chen X; Tang B; Shan J; Qin J; He J; Wu X; Li J; Li A; Hao M; Wen L; Sun X
    Gastrointest Endosc; 2023 May; 97(5):952-961.e1. PubMed ID: 36572127
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bowel preparation using 2-L split-dose polyethylene glycol regimen plus lubiprostone versus 4-L split-dose polyethylene glycol regimen: a randomized controlled trial.
    Sirinawasatien A; Sakulthongthawin P; Chanpiwat K; Chantarojanasiri T
    BMC Gastroenterol; 2022 Sep; 22(1):424. PubMed ID: 36115968
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Split dosing with a low-volume preparation is not inferior to split dosing with a high-volume preparation for bowel cleansing in patients with a history of colorectal resection: a randomized trial.
    Mussetto A; Frazzoni L; Paggi S; Dari S; Laterza L; Radaelli F; Hassan C; Triossi O; Fuccio L
    Endoscopy; 2015 Oct; 47(10):917-24. PubMed ID: 25910064
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Split-dose 4-L polyethylene glycol regimen for patients with previous colorectal surgery in bowel preparation before colonoscopy: A randomized, controlled, single-blind study.
    Liu Z; Li YY; Luo XT; Guo CG; Zhang MM; Li Z; Li LX; Zhang Y; Li YQ
    J Dig Dis; 2018 Jun; 19(6):359-368. PubMed ID: 29790278
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ascorbic acid PEG-2L is superior for early morning colonoscopies in colorectal cancer screening programs: a prospective non-randomized controlled trial.
    Rodríguez de Miguel C; Serradesanferm A; López-Cerón M; Carballal S; Pozo A; Balaguer F; Cárdenas A; Fernández-Esparrach G; Ginés A; González-Suárez B; Moreira L; Ordás I; Ricart E; Sendino O; Vaquero EC; Ubré M; del Manzano S; Grau J; Llach J; Castells A; Pellisé M;
    Gastroenterol Hepatol; 2015 Feb; 38(2):62-70. PubMed ID: 25458542
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.