These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 25634481)

  • 1. Esophageal pressure measurements under different conditions of intrathoracic pressure. An in vitro study of second generation balloon catheters.
    Mojoli F; Chiumello D; Pozzi M; Algieri I; Bianzina S; Luoni S; Volta CA; Braschi A; Brochard L
    Minerva Anestesiol; 2015 Aug; 81(8):855-64. PubMed ID: 25634481
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS.
    Hotz JC; Sodetani CT; Van Steenbergen J; Khemani RG; Deakers TW; Newth CJ
    Respir Care; 2018 Feb; 63(2):177-186. PubMed ID: 29089460
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of esophageal balloon pressure-volume curve analysis to determine esophageal wall elastance and calibrate raw esophageal pressure: a bench experiment and clinical study.
    Sun XM; Chen GQ; Huang HW; He X; Yang YL; Shi ZH; Xu M; Zhou JX
    BMC Anesthesiol; 2018 Feb; 18(1):21. PubMed ID: 29444644
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo calibration of esophageal pressure in the mechanically ventilated patient makes measurements reliable.
    Mojoli F; Iotti GA; Torriglia F; Pozzi M; Volta CA; Bianzina S; Braschi A; Brochard L
    Crit Care; 2016 Apr; 20():98. PubMed ID: 27063290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessing respiratory function depends on mechanical characteristics of balloon catheters.
    Walterspacher S; Isaak L; Guttmann J; Kabitz HJ; Schumann S
    Respir Care; 2014 Sep; 59(9):1345-52. PubMed ID: 24381189
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal esophageal balloon volume for accurate estimation of pleural pressure at end-expiration and end-inspiration: an in vitro bench experiment.
    Yang YL; He X; Sun XM; Chen H; Shi ZH; Xu M; Chen GQ; Zhou JX
    Intensive Care Med Exp; 2017 Dec; 5(1):35. PubMed ID: 28770541
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative analysis of novel esophageal pressure monitoring catheters versus commercially available alternatives in a biomechanical model of the thoracic cavity.
    Abbate G; Colombo SM; Semenzin C; Sato N; Liu K; Ainola C; Milani A; Fior G; Obonyo N; White N; Chiumello D; Pauls J; Suen JY; Fraser JF; Li Bassi G
    Sci Rep; 2024 Apr; 14(1):9771. PubMed ID: 38684823
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Volume-related and volume-independent effects of posture on esophageal and transpulmonary pressures in healthy subjects.
    Washko GR; O'Donnell CR; Loring SH
    J Appl Physiol (1985); 2006 Mar; 100(3):753-8. PubMed ID: 16306256
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Optimal Esophageal Catheter Balloon Inflation Volume in Mechanically Ventilated Children.
    Rudolph MW; Koopman AA; Blokpoel RGT; Kneyber MCJ
    Respir Care; 2024 Feb; 69(3):325-332. PubMed ID: 38195144
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.
    Beda A; Güldner A; Carvalho AR; Zin WA; Carvalho NC; Huhle R; Giannella-Neto A; Koch T; de Abreu MG
    PLoS One; 2014; 9(9):e103057. PubMed ID: 25247308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Accuracy of pressure measurements obtained with a new rectal balloon catheter].
    Le Normand L; Glemain P; Cordonnier JP; Brunel P; Karam G; Boullanger P; Buzelin JM
    Prog Urol; 2001 Feb; 11(1):127-31. PubMed ID: 11296633
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stability and Agreement of a Microtransducer and an Air-Filled Balloon Esophageal Catheter in the Monitoring of Esophageal Pressure.
    Augusto RM; Albuquerque AL; Jaeger T; de Carvalho CR; Caruso P
    Respir Care; 2017 Feb; 62(2):215-221. PubMed ID: 27729399
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Esophageal balloon catheter system identification to improve respiratory effort time features and amplitude determination.
    Xia YHW; Victor MH; Morais CCA; Costa ELV; Amato MBP
    Physiol Meas; 2024 Jan; 45(1):. PubMed ID: 38086063
    [No Abstract]   [Full Text] [Related]  

  • 14. Lung volume dependence of esophageal pressure in the neck.
    Brown IG; McClean PA; Webster PM; Hoffstein V; Zamel N
    J Appl Physiol (1985); 1985 Dec; 59(6):1849-54. PubMed ID: 4077794
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Influence of the catheter diameter on the manometric measurements of the lower esophageal sphincter (LES); with special reference to the application for children].
    Iino M; Takahashi H; Maie M; Oonuma N; Nagai Y; Aoyagi H; Iwai J
    Nihon Heikatsukin Gakkai Zasshi; 1983 Oct; 19(5):415-22. PubMed ID: 6678987
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials.
    Cross TJ; Lalande S; Hyatt RE; Johnson BD
    Physiol Rep; 2015 Jun; 3(6):. PubMed ID: 26077619
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correcting the dynamic response of a commercial esophageal balloon-catheter.
    Cross TJ; Beck KC; Johnson BD
    J Appl Physiol (1985); 2016 Aug; 121(2):503-11. PubMed ID: 27402558
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of pleural pressure swings with a fluid-filled esophageal catheter vs pulmonary artery occlusion pressure.
    Verscheure S; Massion PB; Gottfried S; Goldberg P; Samy L; Damas P; Magder S
    J Crit Care; 2017 Feb; 37():65-71. PubMed ID: 27636673
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Safer urethral catheters: how study of catheter balloon pressure and force can guide design.
    Wu AK; Blaschko SD; Garcia M; McAninch JW; Aaronson DS
    BJU Int; 2012 Apr; 109(7):1110-4. PubMed ID: 21871052
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vivo response of air-filled balloon-tipped catheters to nitrous oxide.
    du Boulay PM; Nahrwold ML
    Anesthesiology; 1982 Dec; 57(6):530-2. PubMed ID: 7149309
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.