These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 25634900)
41. Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors. Miljanić S; Ranogajec-Komor M; Knezević Z; Stuhec M; Prokić M Radiat Prot Dosimetry; 2006; 119(1-4):191-6. PubMed ID: 16709712 [TBL] [Abstract][Full Text] [Related]
42. Energy response of a two-dimensional sheet-type LiF:Mg,Cu,P TL dosemeter to photons. Konnai A; Nariyama N; Ohnishi S; Odano N; Ozasa N; Ishikawa Y Radiat Prot Dosimetry; 2006; 120(1-4):125-8. PubMed ID: 16614093 [TBL] [Abstract][Full Text] [Related]
43. Further studies on the role of dopants in LiF:Mg,Cu,Si thermoluminescent material. Tang K; Fan H; Cui H; Zhu H; Liu Z Radiat Prot Dosimetry; 2015 Feb; 163(3):288-91. PubMed ID: 24966341 [TBL] [Abstract][Full Text] [Related]
44. Synchrotron radiation in the study of the variation of dose response in thermoluminescence dosimeters with radiation energy. Kron T; Smith A; Hyodo K Australas Phys Eng Sci Med; 1996 Dec; 19(4):225-36. PubMed ID: 9060209 [TBL] [Abstract][Full Text] [Related]
45. Effect of reader and oven annealing on the glow curve structure and fading of a LiF:Mg,Cu,P TL dosimeter. Hosseini-Pooya M; Jafarizadeh M J Radiol Prot; 2004 Jun; 24(2):173-8. PubMed ID: 15296261 [TBL] [Abstract][Full Text] [Related]
46. Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P. Luo LZ; Velbeck KJ; Rotunda JE Radiat Prot Dosimetry; 2002; 101(1-4):211-6. PubMed ID: 12382737 [TBL] [Abstract][Full Text] [Related]
47. Measurements of the optical density and the thermoluminescent response of LiF:Mg,Ti exposed to high doses of 60Co gamma rays. Montaño-García C; Gamboa-deBuen I Radiat Prot Dosimetry; 2006; 119(1-4):230-2. PubMed ID: 16644946 [TBL] [Abstract][Full Text] [Related]
48. Use of Chinese LiF:Mg,Cu,P (GR-200) TL detectors at therapy-level absorbed doses. Fill UA; Regulla DF Appl Radiat Isot; 1998 Jul; 49(7):791-3. PubMed ID: 9570098 [TBL] [Abstract][Full Text] [Related]
49. OPTICALLY STIMULATED LUMINESCENCE OF LiF:Mg,Cu,P POWDER-INFLUENCE OF THERMAL TREATMENT. Sądel M; Bilski P; Kłosowski M Radiat Prot Dosimetry; 2019 Dec; 186(4):488-495. PubMed ID: 31330019 [TBL] [Abstract][Full Text] [Related]
50. NUCLEAR HEATING IN LIF DOSEMETERS IN A FUSION NEUTRON FIELD, TRIAL OF DIRECT COMPARISON OF EXPERIMENTAL AND SIMULATED RESULTS. Pohorecki W; Obryk B Radiat Prot Dosimetry; 2018 Aug; 180(1-4):129-133. PubMed ID: 29036685 [TBL] [Abstract][Full Text] [Related]
51. Properties of the 4.45 eV optical absorption band in LiF:Mg,Ti. Nail I; Oster L; Horowitz YS; Biderman S; Belaish Y Radiat Prot Dosimetry; 2006; 119(1-4):244-7. PubMed ID: 16644966 [TBL] [Abstract][Full Text] [Related]
52. Influence of background exposure on detection and determination limits for a TL dosimetry system based on LiF:Mg,Cu,P(GR-200A). Tang KY; Liu BX; Zhu HY; Wang YC; Shen WX Radiat Prot Dosimetry; 2002; 101(1-4):187-90. PubMed ID: 12382732 [TBL] [Abstract][Full Text] [Related]
53. ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,alpha). Mariotti F; Fantuzzi E; Morelli B; Gualdrini G; Botta MC; Uleri G; Bordy JM; Denoziere M Radiat Prot Dosimetry; 2011 Mar; 144(1-4):187-91. PubMed ID: 21224262 [TBL] [Abstract][Full Text] [Related]
54. New thermoluminescent dosimeters (TLD): optimization and characterization of TLD threads sterilizable by autoclave. Jarnet D; Denizot B; Hindré F; Venier-Julienne MC; Lisbona A; Bardiès M; Jallet P Phys Med Biol; 2004 May; 49(9):1803-15. PubMed ID: 15152932 [TBL] [Abstract][Full Text] [Related]
56. Thermoluminescence emission spectra for the LiF:Mg,Cu,Na,Si thermoluminescent materials with various concentrations of the dopants (3-D measurement). Lee JI; Lee D; Kim JL; Chang SY Radiat Prot Dosimetry; 2006; 119(1-4):293-9. PubMed ID: 16644972 [TBL] [Abstract][Full Text] [Related]
57. The dose-response of Harshaw TLD-700H. Velbeck KJ; Luo LZ; Ramlo MJ; Rotunda JE Radiat Prot Dosimetry; 2006; 119(1-4):255-8. PubMed ID: 16581931 [TBL] [Abstract][Full Text] [Related]
58. Influence of readout parameters on TL response, re-usability and residual signal in LiF:Mg,Cu,P. Tang K; Zhao J; Shen W; Zhu H; Wang Y; Liu B Radiat Prot Dosimetry; 2002; 100(1-4):353-6. PubMed ID: 12382896 [TBL] [Abstract][Full Text] [Related]
59. Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields. Ginjaume M; Pérez S; Ortega X; Duch MA Radiat Prot Dosimetry; 2006; 120(1-4):316-20. PubMed ID: 16644980 [TBL] [Abstract][Full Text] [Related]