151 related articles for article (PubMed ID: 25635764)
1. Flow increase is decisive to initiate angiogenesis in veins exposed to altered hemodynamics.
Schmidt VJ; Hilgert JG; Covi JM; Leibig N; Wietbrock JO; Arkudas A; Polykandriotis E; de Wit C; Horch RE; Kneser U
PLoS One; 2015; 10(1):e0117407. PubMed ID: 25635764
[TBL] [Abstract][Full Text] [Related]
2. High flow conditions increase connexin43 expression in a rat arteriovenous and angioinductive loop model.
Schmidt VJ; Hilgert JG; Covi JM; Weis C; Wietbrock JO; de Wit C; Horch RE; Kneser U
PLoS One; 2013; 8(11):e78782. PubMed ID: 24236049
[TBL] [Abstract][Full Text] [Related]
3. Flow Induced Microvascular Network Formation of Therapeutic Relevant Arteriovenous (AV) Loop-Based Constructs in Response to Ionizing Radiation.
Schmidt VJ; Covi JM; Koepple C; Hilgert JG; Polykandriotis E; Bigdeli AK; Distel LV; Horch RE; Kneser U
Med Sci Monit; 2017 Feb; 23():834-842. PubMed ID: 28199294
[TBL] [Abstract][Full Text] [Related]
4. Sprouting from arteriovenous shunt vessels with increased blood flow.
Asano Y; Ichioka S; Shibata M; Ando J; Nakatsuka T
Med Biol Eng Comput; 2005 Jan; 43(1):126-30. PubMed ID: 15742730
[TBL] [Abstract][Full Text] [Related]
5. The venous graft as an effector of early angiogenesis in a fibrin matrix.
Polykandriotis E; Tjiawi J; Euler S; Arkudas A; Hess A; Brune K; Greil P; Lametschwandtner A; Horch RE; Kneser U
Microvasc Res; 2008 Jan; 75(1):25-33. PubMed ID: 17544455
[TBL] [Abstract][Full Text] [Related]
6. Bioengineered vascular access maintains structural integrity in response to arteriovenous flow and repeated needle puncture.
Tillman BW; Yazdani SK; Neff LP; Corriere MA; Christ GJ; Soker S; Atala A; Geary RL; Yoo JJ
J Vasc Surg; 2012 Sep; 56(3):783-93. PubMed ID: 22917043
[TBL] [Abstract][Full Text] [Related]
7. Hemodynamic effects of spiral ePTFE prosthesis compared with standard arteriovenous graft in a carotid to jugular vein porcine model.
Jahrome OK; Hoefer I; Houston GJ; Stonebridge PA; Blankestijn PJ; Moll FL; de Borst GJ
J Vasc Access; 2011; 12(3):224-30. PubMed ID: 21140362
[TBL] [Abstract][Full Text] [Related]
8. Hypertension-induced venous valve remodeling.
Takase S; Pascarella L; Bergan JJ; Schmid-Schönbein GW
J Vasc Surg; 2004 Jun; 39(6):1329-34. PubMed ID: 15192576
[TBL] [Abstract][Full Text] [Related]
9. Haemodynamically stimulated and in vivo generated axially vascularized soft-tissue free flaps for closure of complex defects: Evaluation in a small animal model.
Schmidt VJ; Wietbrock JO; Leibig N; Hernekamp JF; Henn D; Radu CA; Kneser U
J Tissue Eng Regen Med; 2018 Mar; 12(3):622-632. PubMed ID: 28509443
[TBL] [Abstract][Full Text] [Related]
10. Vascularization of the Arteriovenous Loop in a Rat Isolation Chamber Model-Quantification of Hypoxia and Evaluation of Its Effects.
Yuan Q; Arkudas A; Horch RE; Hammon M; Bleiziffer O; Uder M; Seuss H
Tissue Eng Part A; 2018 May; 24(9-10):719-728. PubMed ID: 28978278
[TBL] [Abstract][Full Text] [Related]
11. Combination of extrinsic and intrinsic pathways significantly accelerates axial vascularization of bioartificial tissues.
Arkudas A; Pryymachuk G; Beier JP; Weigel L; Körner C; Singer RF; Bleiziffer O; Polykandriotis E; Horch RE; Kneser U
Plast Reconstr Surg; 2012 Jan; 129(1):55e-65e. PubMed ID: 22186585
[TBL] [Abstract][Full Text] [Related]
12. Modulation of endothelium-dependent responses by chronic alterations of blood flow.
Miller VM; Aarhus LL; Vanhoutte PM
Am J Physiol; 1986 Sep; 251(3 Pt 2):H520-7. PubMed ID: 3752266
[TBL] [Abstract][Full Text] [Related]
13. Tissue engineering skin flaps: which vascular carrier, arteriovenous shunt loop or arteriovenous bundle, has more potential for angiogenesis and tissue generation?
Tanaka Y; Sung KC; Tsutsumi A; Ohba S; Ueda K; Morrison WA
Plast Reconstr Surg; 2003 Nov; 112(6):1636-44. PubMed ID: 14578795
[TBL] [Abstract][Full Text] [Related]
14. In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure.
Varble N; Day S; Phillips D; Mix D; Schwarz K; Illig KA; Chandra A
J Vasc Surg; 2014 May; 59(5):1410-7. PubMed ID: 23845661
[TBL] [Abstract][Full Text] [Related]
15. Does the end-to-end venous anastomosis offer a functional advantage over the end-to-side venous anastomosis in high-output arteriovenous grafts?
Fillinger MF; Kerns DB; Bruch D; Reinitz ER; Schwartz RA
J Vasc Surg; 1990 Dec; 12(6):676-88; discussion 688-90. PubMed ID: 2243404
[TBL] [Abstract][Full Text] [Related]
16. Fibrin gel-immobilized VEGF and bFGF efficiently stimulate angiogenesis in the AV loop model.
Arkudas A; Tjiawi J; Bleiziffer O; Grabinger L; Polykandriotis E; Beier JP; Stürzl M; Horch RE; Kneser U
Mol Med; 2007; 13(9-10):480-7. PubMed ID: 17762899
[TBL] [Abstract][Full Text] [Related]
17. Mechanosensitive transient receptor potential vanilloid type 1 channels contribute to vascular remodeling of rat fistula veins.
Chen YS; Lu MJ; Huang HS; Ma MC
J Vasc Surg; 2010 Nov; 52(5):1310-20. PubMed ID: 20638226
[TBL] [Abstract][Full Text] [Related]
18. Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study.
Sivanesan S; How TV; Black RA; Bakran A
J Biomech; 1999 Sep; 32(9):915-25. PubMed ID: 10460128
[TBL] [Abstract][Full Text] [Related]
19. Cell morphological changes in venous remodeling induced by arteriovenous grafting in rat limb.
Komai Y; Nakano A; Seki J; Niimi H
Clin Hemorheol Microcirc; 2005; 32(4):247-59. PubMed ID: 15894823
[TBL] [Abstract][Full Text] [Related]
20. Flow phenomena in compliant and noncompliant arteriovenous grafts.
Shu MC; Hwang NH
ASAIO Trans; 1988; 34(3):519-23. PubMed ID: 3196556
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]