These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 25636276)

  • 41. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.
    Contreras EF; Henriques GE; Giolo SR; Nobilo MA
    J Prosthet Dent; 2002 Nov; 88(5):467-72. PubMed ID: 12473994
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Study of the surface wear resistance and biological properties of the Ti-Zr-Nb-Sn alloy for dental restoration.
    Hu X; Wei Q; Li CY; Deng JY; Liu S; Zhang LY
    Biomed Mater; 2010 Oct; 5(5):054107. PubMed ID: 20876964
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Microstructure, hardness, corrosion resistance and porcelain shear bond strength comparison between cast and hot pressed CoCrMo alloy for metal-ceramic dental restorations.
    Henriques B; Soares D; Silva FS
    J Mech Behav Biomed Mater; 2012 Aug; 12():83-92. PubMed ID: 22659369
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Mechanical properties, fracture surface characterization, and microstructural analysis of six noble dental casting alloys.
    Ucar Y; Brantley WA; Johnston WM; Dasgupta T
    J Prosthet Dent; 2011 Jun; 105(6):394-402. PubMed ID: 21640241
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Wear resistance of cast dental Ti-Fe alloys.
    Yamaguchi H; Takahashi M; Sasaki K; Takada Y
    Dent Mater J; 2021 Jan; 40(1):68-73. PubMed ID: 32848102
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Production, microstructural characterization and mechanical properties of as-cast Ti-10Mo-xNb alloys.
    Gabriel SB; Nunes CA; Soares Gde A
    Artif Organs; 2008 Apr; 32(4):299-304. PubMed ID: 18370944
    [TBL] [Abstract][Full Text] [Related]  

  • 47. In vitro fracture strength and thermal shock resistance of metal-ceramic crowns with cast and machined AuTi frameworks.
    Kellerhoff RK; Fischer J
    J Prosthet Dent; 2007 Apr; 97(4):209-15. PubMed ID: 17499090
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.
    de Oliveira Correa G; Henriques GE; Mesquita MF; Sobrinho LC
    J Prosthet Dent; 2006 Mar; 95(3):243-8. PubMed ID: 16543023
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants.
    Elias CN; Fernandes DJ; Resende CR; Roestel J
    Dent Mater; 2015 Feb; 31(2):e1-e13. PubMed ID: 25458351
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Microstructure and mechanical properties of Ti-Zr-Cr biomedical alloys.
    Wang P; Feng Y; Liu F; Wu L; Guan S
    Mater Sci Eng C Mater Biol Appl; 2015 Jun; 51():148-52. PubMed ID: 25842119
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Mechanical properties of dental Ti-Ag alloys with 22.5, 25, 27.5, and 30 mass% Ag.
    Takahashi M; Kikuchi M; Takada Y
    Dent Mater J; 2015; 34(4):503-7. PubMed ID: 26235716
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials.
    Kobayashi E; Matsumoto S; Doi H; Yoneyama T; Hamanaka H
    J Biomed Mater Res; 1995 Aug; 29(8):943-50. PubMed ID: 7593037
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Analysis of four dental alloys following torch/centrifugal and induction/ vacuum-pressure casting procedures.
    Thompson GA; Luo Q; Hefti A
    J Prosthet Dent; 2013 Dec; 110(6):471-80. PubMed ID: 24120072
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Mold filling and microhardness of 1% Fe titanium alloys.
    Sato H; Komatsu M; Miller B; Shimizu H; Fujii H; Okabe T
    Dent Mater J; 2004 Jun; 23(2):211-7. PubMed ID: 15287570
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Grindability of dental cast Ti-Ag and Ti-Cu alloys.
    Kikuchi M; Takahashi M; Okabe T; Okuno O
    Dent Mater J; 2003 Jun; 22(2):191-205. PubMed ID: 12873122
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Properties of cobalt-chromium metal ceramic alloys after heat treatment.
    Morris HF
    J Prosthet Dent; 1990 Apr; 63(4):426-33. PubMed ID: 2329540
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Characterization of two Ni-Cr dental alloys and the influence of casting mode on mechanical properties.
    Bauer J; Costa JF; Carvalho CN; Grande RH; Loguercio AD; Reis A
    J Prosthodont Res; 2012 Oct; 56(4):264-71. PubMed ID: 22609222
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Structure, castability and mechanical properties of commercially pure and alloyed titanium cast in graphite mould.
    Cheng WW; Ju CP; Lin JH
    J Oral Rehabil; 2007 Jul; 34(7):528-40. PubMed ID: 17559621
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Plasma nitriding of titanium alloy: Effect of roughness, hardness, biocompatibility, and bonding with bone cement.
    Khandaker M; Riahinezhad S; Li Y; Vaughan MB; Sultana F; Morris TL; Phinney L; Hossain K
    Biomed Mater Eng; 2016 Nov; 27(5):461-474. PubMed ID: 27885994
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Laser surface treatment to improve mechanical properties of cast titanium.
    Watanabe I; McBride M; Newton P; Kurtz KS
    Dent Mater; 2009 May; 25(5):629-33. PubMed ID: 19121866
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.