These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 25636625)

  • 1. The first North American use of the Pipeline Flex flow diverter.
    Duckworth EA; Nickele C; Hoit D; Belayev A; Moran CJ; Arthur AS
    BMJ Case Rep; 2015 Jan; 2015():. PubMed ID: 25636625
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The first North American use of the Pipeline Flex flow diverter.
    Duckworth EA; Nickele C; Hoit D; Belayev A; Moran CJ; Arthur AS
    J Neurointerv Surg; 2016 Feb; 8(2):e8. PubMed ID: 25653230
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Immediate procedural outcomes in 44 consecutive Pipeline Flex cases: the first North American single-center series.
    Colby GP; Lin LM; Caplan JM; Jiang B; Huang J; Tamargo RJ; Coon AL
    J Neurointerv Surg; 2016 Jul; 8(7):702-9. PubMed ID: 26136500
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Declining complication rates with flow diversion of anterior circulation aneurysms after introduction of the Pipeline Flex: analysis of a single-institution series of 568 cases.
    Colby GP; Bender MT; Lin LM; Beaty N; Caplan JM; Jiang B; Westbroek EM; Varjavand B; Campos JK; Huang J; Tamargo RJ; Coon AL
    J Neurosurg; 2018 Dec; 129(6):1475-1481. PubMed ID: 29327999
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization device.
    Colby GP; Lin LM; Huang J; Tamargo RJ; Coon AL
    J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii16-21. PubMed ID: 23516269
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms.
    Aguilar-Salinas P; Brasiliense LB; Gonsales D; Mitchell B; Lima A; Sauvageau E; Hanel R
    Expert Rev Med Devices; 2016 Oct; 13(10):885-897. PubMed ID: 27647130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Preliminary experience with the Pipeline Flex Embolization Device: technical note.
    Martínez-Galdámez M; Gil A; Caniego JL; Gonzalez E; Bárcena E; Perez S; Garcia-Bermejo P; Ortega-Gutierrez S
    J Neurointerv Surg; 2015 Oct; 7(10):748-51. PubMed ID: 25165385
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endovascular treatment of complex intracranial aneurysms by pipeline flow-diverter embolization device: a single-center experience.
    Keskin F; Erdi F; Kaya B; Poyraz N; Keskin S; Kalkan E; Ozbek O; Koc O
    Neurol Res; 2015 Apr; 37(4):359-65. PubMed ID: 25310354
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New Pipeline Flex device: initial experience and technical nuances.
    Pereira VM; Kelly M; Vega P; Murias E; Yilmaz H; Erceg G; Pellaton A; Lovblad KO; Krings T
    J Neurointerv Surg; 2015 Dec; 7(12):920-5. PubMed ID: 25280568
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endovascular treatment of intracranial aneurysms using the Pipeline Flex embolization device: a case series of 30 consecutive patients.
    Martínez-Galdámez M; Pérez S; Vega A; Ruiz P; Caniego JL; Bárcena E; Saura P; Méndez JC; Delgado F; Ortega-Gutierrez S; Romance A; Diaz T; Gonzalez E; Gil A; Murias E; Vega P
    J Neurointerv Surg; 2016 Apr; 8(4):396-401. PubMed ID: 25770120
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intra-DIC (distal intracranial catheter) deployment of the Pipeline embolization device: a novel rescue strategy for failed device expansion.
    Lin LM; Colby GP; Jiang B; Nundkumar N; Huang J; Tamargo RJ; Coon AL
    J Neurointerv Surg; 2016 Aug; 8(8):840-6. PubMed ID: 26101269
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pipeline flow diversion of ruptured blister aneurysms of the supraclinoid carotid artery using a single-device strategy.
    Ryan RW; Khan AS; Barco R; Choulakian A
    Neurosurg Focus; 2017 Jun; 42(6):E11. PubMed ID: 28565992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of the 0.027-inch VIA microcatheter for delivery of Pipeline Flex: a technical note.
    Lin LM; Colby GP; Bender MT; Xu R; Huang J; Tamargo RJ; Coon AL
    J Neurointerv Surg; 2017 Jul; 9(7):689-693. PubMed ID: 28151413
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pipeline-assisted coiling versus pipeline in flow diversion treatment of intracranial aneurysms.
    Sweid A; Atallah E; Herial N; Saad H; Mouchtouris N; Barros G; Gooch MR; Tjoumakaris S; Zarzour H; Hasan D; Chalouhi N; Rosenwasser RH; Jabbour P
    J Clin Neurosci; 2018 Dec; 58():20-24. PubMed ID: 30454690
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center.
    Briganti F; Leone G; Cirillo L; de Divitiis O; Solari D; Cappabianca P
    Neurosurg Focus; 2017 Jun; 42(6):E3. PubMed ID: 28565988
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study.
    Martínez-Galdámez M; Lamin SM; Lagios KG; Liebig T; Ciceri EF; Chapot R; Stockx L; Chavda S; Kabbasch C; Farago G; Nordmeyer H; Boulanger T; Piano M; Boccardi EP
    J Neurointerv Surg; 2017 Aug; 9(8):772-776. PubMed ID: 28223428
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Age-related outcomes following intracranial aneurysm treatment with the Pipeline Embolization Device: a subgroup analysis of the IntrePED registry.
    Brinjikji W; Kallmes DF; Cloft HJ; Lanzino G
    J Neurosurg; 2016 Jun; 124(6):1726-30. PubMed ID: 26544776
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical and angiographic outcomes in patients with intracranial aneurysms treated with the pipeline embolization device: intra-procedural technical difficulties, major morbidity, and neurological mortality decrease significantly with increased operator experience in device deployment and patient management.
    Delgado Almandoz JE; Kayan Y; Tenreiro A; Wallace AN; Scholz JM; Fease JL; Milner AM; Mulder M; Uittenbogaard KM; Tenreiro-Picón O
    Neuroradiology; 2017 Dec; 59(12):1291-1299. PubMed ID: 28986614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Incidence of delivery wire recapture failure with the Pipeline Flex device.
    Mooney MA; Moon K; Gross BA; Ducruet AF; Albuquerque FC
    J Neurointerv Surg; 2017 Jun; 9(6):571-573. PubMed ID: 28100649
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow diversion with the pipeline embolization device for patients with intracranial aneurysms and antiplatelet therapy: A systematic literature review.
    Texakalidis P; Bekelis K; Atallah E; Tjoumakaris S; Rosenwasser RH; Jabbour P
    Clin Neurol Neurosurg; 2017 Oct; 161():78-87. PubMed ID: 28863286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.