BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 25639426)

  • 1. Simultaneous double valve-in-valve TAVI procedure for failed bioprostheses.
    Schlömicher M; Haldenwang PL; Moustafine V; Bechtel M; Strauch JT
    Ann Thorac Surg; 2015 Feb; 99(2):722-4. PubMed ID: 25639426
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Double transcatheter valve-in-valve implantation for degenerated aortic and mitral bioprostheses.
    Faria R; Rodrigues A; Santos N; Vouga L; Gama V
    Rev Port Cir Cardiotorac Vasc; 2013; 20(3):131-4. PubMed ID: 25177739
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous transcatheter aortic and mitral valve-in-valve implantation in a patient with degenerated bioprostheses and high surgical risk.
    Seiffert M; Baldus S; Conradi L; Koschyk D; Schirmer J; Meinertz T; Reichenspurner H; Treede H
    Thorac Cardiovasc Surg; 2011 Dec; 59(8):490-2. PubMed ID: 22081322
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transapical transcatheter valve-in-valve replacement for deteriorated mitral valve bioprosthesis without radio-opaque indicators: the "invisible" mitral valve bioprosthesis.
    Rossi ML; Barbaro C; Pagnotta P; Cappai A; Ornaghi D; Belli G; Presbitero P
    Heart Lung Circ; 2015 Feb; 24(2):e19-22. PubMed ID: 25456504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. First Australian transapical mitral valve-in-valve implant for a failed mitral bioprosthesis: how to do it.
    Poon KK; Clarke A; Luis SA; Wiemers P; Incani A; Scalia G; Tesar P; Raffel OC; Aroney CN; Walters DL
    Heart Lung Circ; 2012 Nov; 21(11):737-9. PubMed ID: 22595453
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis.
    Attia R; Bapat V
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):324-7. PubMed ID: 22120953
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter ACURATE-TA Aortic Valve Implantation in a Patient With a Previous Mechanical Mitral Valve.
    Bagur R; Kiaii B; Teefy PJ; Diamantouros P; Harle C; Goela A; Chan I; Chu MW
    Ann Thorac Surg; 2015 Nov; 100(5):e115-7. PubMed ID: 26522576
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcatheter valve-in-valve implantation for deteriorated aortic bioprosthesis: initial clinical results and follow-up in a series of high-risk patients.
    Wilbring M; Sill B; Tugtekin SM; Alexiou K; Simonis G; Matschke K; Kappert U
    Ann Thorac Surg; 2012 Mar; 93(3):734-41. PubMed ID: 22304904
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
    Ruel M; Kulik A; Rubens FD; Bédard P; Masters RG; Pipe AL; Mesana TG
    Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Morphologic findings in explanted Hancock II porcine bioprostheses.
    Butany J; Yu W; Silver MD; David TE
    J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Short- and mid-term safety and effectiveness of transcatheter aortic valve implantation in a failing surgical aortic bioprosthesis.
    Ong SH; Bauernschmitt R; Schuler G; Mueller R
    Eur J Cardiothorac Surg; 2012 Aug; 42(2):268-76; discussion 276. PubMed ID: 22334629
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
    Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves.
    Eggebrecht H; Schäfer U; Treede H; Boekstegers P; Babin-Ebell J; Ferrari M; Möllmann H; Baumgartner H; Carrel T; Kahlert P; Lange P; Walther T; Erbel R; Mehta RH; Thielmann M
    JACC Cardiovasc Interv; 2011 Nov; 4(11):1218-27. PubMed ID: 22115663
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Late results of heart valve replacement with the Hancock II bioprosthesis.
    David TE; Ivanov J; Armstrong S; Feindel CM; Cohen G
    J Thorac Cardiovasc Surg; 2001 Feb; 121(2):268-77. PubMed ID: 11174732
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fifteen-year results with the Hancock II valve: a multicenter experience.
    Rizzoli G; Mirone S; Ius P; Polesel E; Bottio T; Salvador L; Zussa C; Gerosa G; Valfrè C
    J Thorac Cardiovasc Surg; 2006 Sep; 132(3):602-9, 609.e1-4. PubMed ID: 16935116
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Long-term follow-up of aortic or mitral valve replacement. Comparison of results following implantation of a mechanical or biological artificial valve].
    Mudra H; Rudolph W
    Herz; 1986 Apr; 11(2):97-115. PubMed ID: 3699678
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position].
    Hayashi K; Nakano H; Sakamoto T; Okamura H
    Kyobu Geka; 2000 Jan; 53(1):79-82. PubMed ID: 10639799
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the quantity of calcific deposits in bovine pericardial bioprostheses in the mitral and aortic valve positions in the same patient late after double-valve replacement.
    Roberts WC; Velasco CE; Ko JM; Matter GJ
    J Thorac Cardiovasc Surg; 2009 Dec; 138(6):1448-50. PubMed ID: 19660352
    [No Abstract]   [Full Text] [Related]  

  • 19. [Redo double valve replacement in a patient with bioprosthetic valve malfunction by pannus formation; report of a case].
    Hiranuma S; Nabuchi A; Okuyama H; Muto Y; Endo M
    Kyobu Geka; 2014 Oct; 67(11):1017-20. PubMed ID: 25292380
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Short-term results of transapical transcatheter mitral valve implantation for mitral regurgitation.
    Cheung A; Webb J; Verheye S; Moss R; Boone R; Leipsic J; Ree R; Banai S
    J Am Coll Cardiol; 2014 Oct; 64(17):1814-9. PubMed ID: 25443704
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.