BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 25640900)

  • 1. In vivo implant forces acting on a vertebral body replacement during upper body flexion.
    Dreischarf M; Albiol L; Zander T; Arshad R; Graichen F; Bergmann G; Schmidt H; Rohlmann A
    J Biomech; 2015 Feb; 48(4):560-565. PubMed ID: 25640900
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spinal loads as influenced by external loads: a combined in vivo and in silico investigation.
    Zander T; Dreischarf M; Schmidt H; Bergmann G; Rohlmann A
    J Biomech; 2015 Feb; 48(4):578-584. PubMed ID: 25648494
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo hip and lumbar spine implant loads during activities in forward bent postures.
    Damm P; Reitmaier S; Hahn S; Waldheim V; Firouzabadi A; Schmidt H
    J Biomech; 2020 Mar; 102():109517. PubMed ID: 31767284
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measured loads on a vertebral body replacement during sitting.
    Rohlmann A; Zander T; Graichen F; Dreischarf M; Bergmann G
    Spine J; 2011 Sep; 11(9):870-5. PubMed ID: 21775218
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Loads on a vertebral body replacement during locomotion measured in vivo.
    Rohlmann A; Dreischarf M; Zander T; Graichen F; Bergmann G
    Gait Posture; 2014 Feb; 39(2):750-5. PubMed ID: 24211089
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Loads on a telemeterized vertebral body replacement measured in two patients.
    Rohlmann A; Graichen F; Kayser R; Bender A; Bergmann G
    Spine (Phila Pa 1976); 2008 May; 33(11):1170-9. PubMed ID: 18469689
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correlation between back shape and spinal loads.
    Srbinoska H; Dreischarf M; Consmüller T; Bergmann G; Rohlmann A
    J Biomech; 2013 Jul; 46(11):1972-5. PubMed ID: 23726182
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of an orthosis on the loads acting on a vertebral body replacement.
    Rohlmann A; Zander T; Graichen F; Bergmann G
    Clin Biomech (Bristol, Avon); 2013 Jun; 28(5):490-4. PubMed ID: 23623494
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month.
    Rohlmann A; Graichen F; Bender A; Kayser R; Bergmann G
    Clin Biomech (Bristol, Avon); 2008 Feb; 23(2):147-58. PubMed ID: 17983694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability.
    Rohlmann A; Bergmann G; Graichen F; Mayer HM
    Spine (Phila Pa 1976); 1995 Dec; 20(24):2683-9. PubMed ID: 8747246
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Trunk active response and spinal forces in sudden forward loading: analysis of the role of perturbation load and pre-perturbation conditions by a kinematics-driven model.
    Shahvarpour A; Shirazi-Adl A; Larivière C; Bazrgari B
    J Biomech; 2015 Jan; 48(1):44-52. PubMed ID: 25476501
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How does the way a weight is carried affect spinal loads?
    Rohlmann A; Zander T; Graichen F; Schmidt H; Bergmann G
    Ergonomics; 2014; 57(2):262-70. PubMed ID: 24559120
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of lumbar spine rhythms and intra-abdominal pressure on spinal loads and trunk muscle forces during upper body inclination.
    Arshad R; Zander T; Dreischarf M; Schmidt H
    Med Eng Phys; 2016 Apr; 38(4):333-8. PubMed ID: 26922676
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Braces do not reduce loads on internal spinal fixation devices.
    Rohlmann A; Bergmann G; Graichen F; Neff G
    Clin Biomech (Bristol, Avon); 1999 Feb; 14(2):97-102. PubMed ID: 10619096
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo loads on a vertebral body replacement during different lifting techniques.
    Dreischarf M; Rohlmann A; Graichen F; Bergmann G; Schmidt H
    J Biomech; 2016 Apr; 49(6):890-895. PubMed ID: 26603872
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Load-sharing in the lumbosacral spine in neutral standing & flexed postures - A combined finite element and inverse static study.
    Liu T; Khalaf K; Naserkhaki S; El-Rich M
    J Biomech; 2018 Mar; 70():43-50. PubMed ID: 29153706
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Spinal load bearing during sitting in an office chair with a tilting back].
    Rohlmann A; Wilke HJ; Graichen F; Bergmann G
    Biomed Tech (Berl); 2002 Apr; 47(4):91-6. PubMed ID: 12051139
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spinal loads during position changes.
    Rohlmann A; Petersen R; Schwachmeyer V; Graichen F; Bergmann G
    Clin Biomech (Bristol, Avon); 2012 Oct; 27(8):754-8. PubMed ID: 22571842
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lumbar spinal loads and lumbar muscle forces evaluation with various lumbar supports and backrest inclination angles in driving posture.
    Gao K; Du J; Ding R; Zhang Z
    Eur Spine J; 2023 Feb; 32(2):408-419. PubMed ID: 36380009
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis.
    Rohlmann A; Burra NK; Zander T; Bergmann G
    Eur Spine J; 2007 Aug; 16(8):1223-31. PubMed ID: 17206401
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.