BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 25645414)

  • 1. Comparison of symmetric hemodialysis catheters using computational fluid dynamics.
    Clark TW; Isu G; Gallo D; Verdonck P; Morbiducci U
    J Vasc Interv Radiol; 2015 Feb; 26(2):252-9.e2. PubMed ID: 25645414
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational flow dynamics and preclinical assessment of a novel hemodialysis catheter.
    Clark TW; Van Canneyt K; Verdonck P
    Semin Dial; 2012; 25(5):574-81. PubMed ID: 22353667
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of recirculation percentage of the palindrome catheter and standard hemodialysis catheters in a swine model.
    Tal MG
    J Vasc Interv Radiol; 2005 Sep; 16(9):1237-40. PubMed ID: 16151065
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Clinical Performance of VectorFlow and Palindrome Symmetric-Tip Dialysis Catheters: A Multicenter, Randomized Trial.
    Nadolski GJ; Redmond J; Shin B; Shamimi-Noori S; Vance A; Hammelman B; Clark TWI; Cohen R; Rudnick M
    J Vasc Interv Radiol; 2020 Jul; 31(7):1148-1155. PubMed ID: 32534972
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Initial Clinical Experience: Symmetric-Tip Dialysis Catheter with Helical Flow Characteristics Improves Patient Outcomes.
    Clark TW; Redmond JW; Mantell MP; Nadolski GJ; Mondschein JI; Dowd MF; Dagli MS; Sudheendra D; Shlansky-Goldberg RD; Cohen RD
    J Vasc Interv Radiol; 2015 Oct; 26(10):1501-8. PubMed ID: 26239895
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodialysis catheter tip design: observations on fluid flow and recirculation.
    Vesely TM; Ravenscroft A
    J Vasc Access; 2016; 17(1):29-39. PubMed ID: 26349860
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemodialysis catheter design and catheter performance: a randomized controlled trial.
    Van Der Meersch H; De Bacquer D; Vandecasteele SJ; Van den Bergh B; Vermeiren P; De Letter J; De Vriese AS
    Am J Kidney Dis; 2014 Dec; 64(6):902-8. PubMed ID: 24713222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Longitudinal dialysis adequacy and clinical performance of the VectorFlow hemodialysis catheter: a prospective study.
    Ross JR; Puga TA; Philbeck TE
    J Vasc Access; 2017 Nov; 18(6):492-497. PubMed ID: 28862725
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical/experimental synergy: more than just a reality check.
    Ballyk PD
    J Vasc Interv Radiol; 2015 Feb; 26(2):259-61. PubMed ID: 25645415
    [No Abstract]   [Full Text] [Related]  

  • 10. All currently used measurements of recirculation in blood access by chemical methods are flawed due to intradialytic disequilibrium or recirculation at low flow.
    Twardowski ZJ; Van Stone JC; Haynie JD
    Am J Kidney Dis; 1998 Dec; 32(6):1046-58. PubMed ID: 9856523
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational fluid dynamics-analysis of the Niagara hemodialysis catheter in a right heart model.
    Mareels G; De Wachter DS; Verdonck PR
    Artif Organs; 2004 Jul; 28(7):639-48. PubMed ID: 15209857
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blood recirculation in temporary central catheters for acute hemodialysis.
    Leblanc M; Fedak S; Mokris G; Paganini EP
    Clin Nephrol; 1996 May; 45(5):315-9. PubMed ID: 8738663
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Particle image velocimetry-validated, computational fluid dynamics-based design to reduce shear stress and residence time in central venous hemodialysis catheters.
    Mareels G; Kaminsky R; Eloot S; Verdonck PR
    ASAIO J; 2007; 53(4):438-46. PubMed ID: 17667228
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluid mechanics and clinical success of central venous catheters for dialysis--answers to simple but persisting problems.
    Ash SR
    Semin Dial; 2007; 20(3):237-56. PubMed ID: 17555490
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Blood flow in hemodialysis catheters: a numerical simulation and microscopic analysis of in vivo-formed fibrin.
    Lucas TC; Tessarolo F; Jakitsch V; Caola I; Brunori G; Nollo G; Huebner R
    Artif Organs; 2014 Jul; 38(7):556-65. PubMed ID: 24341622
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computational fluid dynamics of the right atrium: Assessment of modelling criteria for the evaluation of dialysis catheters.
    de Oliveira DC; Owen DG; Qian S; Green NC; Espino DM; Shepherd DET
    PLoS One; 2021; 16(2):e0247438. PubMed ID: 33630903
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Recirculation of urea and dialysis efficiency using dual-lumen dialysis catheters in various locations: may the venous lumen of the catheter be used as the arterial lumen and vice versa?].
    Sefer S; Kes P; Degoricija V; Heinrich B; Vrsalović M
    Lijec Vjesn; 2003; 125(1-2):1-5. PubMed ID: 12812016
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of side-hole geometry on the performance of hemodialysis catheter tips: A computational fluid dynamics assessment.
    Owen DG; de Oliveira DC; Qian S; Green NC; Shepherd DET; Espino DM
    PLoS One; 2020; 15(8):e0236946. PubMed ID: 32764790
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Numerical and experimental flow analysis of the Wang-Zwische double-lumen cannula.
    De Bartolo C; Nigro A; Fragomeni G; Colacino FM; Wang D; Jones CC; Zwischenberger J
    ASAIO J; 2011; 57(4):318-27. PubMed ID: 21654494
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical application of long-term Palindrome catheter in hemodialysis patients.
    Li M; Zhang Z; Yu Y; Chen H; Li X; Ma J; Dong Z
    Iran J Kidney Dis; 2014 Mar; 8(2):123-9. PubMed ID: 24685735
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.