These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 25648017)

  • 1. Automated cell analysis of cerebrospinal fluid with XE-5000.
    Liang X; Chen J; Xiao X; Yu Y; Li W; Zhang Z
    Clin Lab; 2014; 60(11):1785-93. PubMed ID: 25648017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the automated hematology analyzer ADVIA® 120 for cerebrospinal fluid analysis and usage of unique hemolysis reagent.
    Tanada H; Ikemoto T; Masutani R; Tanaka H; Takubo T
    Int J Lab Hematol; 2014 Feb; 36(1):83-91. PubMed ID: 23937551
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A New Automated Technology for Cerebrospinal Fluid Cell Counts: Comparison of Accuracy and Clinical Impact of GloCyte, Sysmex XN, and Manual Methods.
    Sandhaus LM; Dillman CA; Hinkle WP; MacKenzie JM; Hong G
    Am J Clin Pathol; 2017 May; 147(5):507-514. PubMed ID: 28419185
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i.
    Buoro S; Apassiti Esposito S; Alessio M; Crippa A; Ottomano C; Lippi G
    J Clin Lab Anal; 2016 Sep; 30(5):381-91. PubMed ID: 26302990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid.
    Boer K; Deufel T; Reinhoefer M
    Clin Biochem; 2009 May; 42(7-8):684-91. PubMed ID: 19233149
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated white blood cell counts in cerebrospinal fluid using the body fluid mode on the platform Sysmex XE-5000.
    Li A; Grönlund E; Brattsand G
    Scand J Clin Lab Invest; 2014 Nov; 74(8):673-80. PubMed ID: 25180445
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated cerebrospinal fluid cell counts using the Sysmex XE-5000: is it time for new reference ranges?
    Sandhaus LM; Ciarlini P; Kidric D; Dillman C; O'Riordan M
    Am J Clin Pathol; 2010 Nov; 134(5):734-8. PubMed ID: 20959656
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids.
    de Jonge R; Brouwer R; de Graaf MT; Luitwieler RL; Fleming C; de Frankrijker-Merkestijn M; Sillevis Smitt PA; Boonstra JG; Lindemans J
    Clin Chem Lab Med; 2010 May; 48(5):665-75. PubMed ID: 20187854
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Sysmex XN-1000 High-Sensitive Analysis (hsA) Research Mode for Counting and Differentiating Cells in Cerebrospinal Fluid.
    Fleming C; Russcher H; Brouwer R; Lindemans J; de Jonge R
    Am J Clin Pathol; 2016 Mar; 145(3):299-307. PubMed ID: 27124911
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Cell Counting in Body Fluids: Comparison of Two Automated Hematology Analyzers with Manual Microscopy.
    Genc S; Dervisoglu E; Omer D; Kucukates E; Omer B; Ademoglu E
    Clin Lab; 2016 Dec; 62(12):2449-2453. PubMed ID: 28164566
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An evaluation of the cell-dyn 3200 for counting cells in cerebrospinal and other body fluids.
    Andrews J; Setran E; McDonnel L; Kussick S; Wood BL; Sabath DE
    Lab Hematol; 2005; 11(2):98-106. PubMed ID: 16024333
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance evaluation of the Sysmex XE-5000 hematology analyzer for white blood cell analysis in cerebrospinal fluid.
    Perné A; Hainfellner JA; Womastek I; Haushofer A; Szekeres T; Schwarzinger I
    Arch Pathol Lab Med; 2012 Feb; 136(2):194-8. PubMed ID: 22288968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of white and red blood cell estimates in urine sediment with hemocytometer and automated counts in dogs and cats.
    O'Neil E; Burton S; Horney B; MacKenzie A
    Vet Clin Pathol; 2013 Mar; 42(1):78-84. PubMed ID: 23205885
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.
    Hod EA; Brugnara C; Pilichowska M; Sandhaus LM; Luu HS; Forest SK; Netterwald JC; Reynafarje GM; Kratz A
    Int J Lab Hematol; 2018 Feb; 40(1):56-65. PubMed ID: 28880455
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance evaluation of the application of body fluids on the Sysmex XE-2100 series automated hematology analyzer.
    Kresie L; Benavides D; Bollinger P; Walters J; Pierson D; Richmond T; Issa-Dyer K; Fahs M
    Lab Hematol; 2005; 11(1):24-30. PubMed ID: 15790549
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cell analysis in cerebrospinal fluid (CSF) using Sysmex® hematology analyzers XT-4000i and XE-5000: evaluation with CSF controls of the Joint German Society for Clinical Chemistry and Laboratory Medicine (DGKL).
    Kleine TO; Nebe CT; Löwer C; Geilenkeuser WJ; Dorn-Beineke A
    Cytometry A; 2012 Mar; 81(3):255-64. PubMed ID: 22253065
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance evaluation of the body fluid mode on the platform Sysmex XE-5000 series automated hematology analyzer.
    Paris A; Nhan T; Cornet E; Perol JP; Malet M; Troussard X
    Int J Lab Hematol; 2010 Oct; 32(5):539-47. PubMed ID: 20236183
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interpretation of traumatic lumbar punctures: who can go home?
    Mazor SS; McNulty JE; Roosevelt GE
    Pediatrics; 2003 Mar; 111(3):525-8. PubMed ID: 12612231
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of the performances of the UF-1000i(®) automated urine analyzer].
    Fabbro C; Darolles J; Rault JP
    Ann Biol Clin (Paris); 2011; 69(4):431-9. PubMed ID: 21896408
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated counting of white and red blood cells in the cerebrospinal fluid.
    Aune MW; Sandberg S
    Clin Lab Haematol; 2000 Aug; 22(4):203-10. PubMed ID: 11012631
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.