BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 25652482)

  • 1. Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources.
    Martínez-Rovira I; Fois G; Prezado Y
    Med Phys; 2015 Feb; 42(2):685-93. PubMed ID: 25652482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dose evaluation of Grid Therapy using a 6 MV flattening filter-free (FFF) photon beam: A Monte Carlo study.
    Martínez-Rovira I; Puxeu-Vaqué J; Prezado Y
    Med Phys; 2017 Oct; 44(10):5378-5383. PubMed ID: 28736809
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minibeam radiation therapy for the management of osteosarcomas: a Monte Carlo study.
    Martínez-Rovira I; Prezado Y
    Med Phys; 2014 Jun; 41(6):061706. PubMed ID: 24877801
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improving the dose distributions in minibeam radiation therapy: Helium ions vs protons.
    Schneider T; Patriarca A; Prezado Y
    Med Phys; 2019 Aug; 46(8):3640-3648. PubMed ID: 31173369
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo dose enhancement studies in microbeam radiation therapy.
    Martínez-Rovira I; Prezadoa Y
    Med Phys; 2011 Jul; 38(7):4430-9. PubMed ID: 21859044
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mini-GRID radiotherapy on the CLEAR very-high-energy electron beamline: collimator optimization, film dosimetry, and Monte Carlo simulations.
    Clements N; Esplen N; Bateman J; Robertson C; Dosanjh M; Korysko P; Farabolini W; Corsini R; Bazalova-Carter M
    Phys Med Biol; 2024 Feb; 69(5):. PubMed ID: 38295408
    [No Abstract]   [Full Text] [Related]  

  • 7. Optimization of the mechanical collimation for minibeam generation in proton minibeam radiation therapy.
    Guardiola C; Peucelle C; Prezado Y
    Med Phys; 2017 Apr; 44(4):1470-1478. PubMed ID: 28129665
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spatial fractionation of the dose using neon and heavier ions: A Monte Carlo study.
    Peucelle C; Martínez-Rovira I; Prezado Y
    Med Phys; 2015 Oct; 42(10):5928-36. PubMed ID: 26429267
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Theoretical dosimetric evaluation of carbon and oxygen minibeam radiation therapy.
    González W; Peucelle C; Prezado Y
    Med Phys; 2017 May; 44(5):1921-1929. PubMed ID: 28236644
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Proton-minibeam radiation therapy: a proof of concept.
    Prezado Y; Fois GR
    Med Phys; 2013 Mar; 40(3):031712. PubMed ID: 23464307
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Proton minibeam radiation therapy: Experimental dosimetry evaluation.
    Peucelle C; Nauraye C; Patriarca A; Hierso E; Fournier-Bidoz N; Martínez-Rovira I; Prezado Y
    Med Phys; 2015 Dec; 42(12):7108-13. PubMed ID: 26632064
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatial fractionation of the dose in heavy ions therapy: An optimization study.
    González W; Prezado Y
    Med Phys; 2018 Jun; 45(6):2620-2627. PubMed ID: 29633284
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and commissioning of a Monte Carlo photon beam model for the forthcoming clinical trials in microbeam radiation therapy.
    Martínez-Rovira I; Sempau J; Prezado Y
    Med Phys; 2012 Jan; 39(1):119-31. PubMed ID: 22225281
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proton microbeam radiotherapy with scanned pencil-beams--Monte Carlo simulations.
    Kłodowska M; Olko P; Waligórski MP
    Phys Med; 2015 Sep; 31(6):621-6. PubMed ID: 25982232
    [TBL] [Abstract][Full Text] [Related]  

  • 15. X-ray energy optimization in minibeam radiation therapy.
    Prezado Y; Thengumpallil S; Renier M; Bravin A
    Med Phys; 2009 Nov; 36(11):4897-902. PubMed ID: 19994498
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo optimization of a GRID collimator for preclinical megavoltage ultra-high dose rate spatially-fractionated radiation therapy.
    Clements N; Bazalova-Carter M; Esplen N
    Phys Med Biol; 2022 Sep; 67(18):. PubMed ID: 35998651
    [No Abstract]   [Full Text] [Related]  

  • 17. Spatially fractionated (GRID) radiation therapy using proton pencil beam scanning (PBS): Feasibility study and clinical implementation.
    Gao M; Mohiuddin MM; Hartsell WF; Pankuch M
    Med Phys; 2018 Apr; 45(4):1645-1653. PubMed ID: 29431867
    [TBL] [Abstract][Full Text] [Related]  

  • 18. First experimental measurement of the effect of cardio-synchronous brain motion on the dose distribution during microbeam radiation therapy.
    Duncan M; Donzelli M; Pellicioli P; Brauer-Krisch E; Davis JA; Lerch MLF; Rosenfeld AB; Petasecca M
    Med Phys; 2020 Jan; 47(1):213-222. PubMed ID: 31680274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A feasibility study of ultra-high dose rate mini-GRID therapy using very-high-energy electron beams for a simulated pediatric brain case.
    Clements N; Esplen N; Bazalova-Carter M
    Phys Med; 2023 Aug; 112():102637. PubMed ID: 37454482
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of dose size in single fraction spatially fractionated (grid) radiotherapy for melanoma.
    Zhang H; Zhong H; Barth RF; Cao M; Das IJ
    Med Phys; 2014 Feb; 41(2):021727. PubMed ID: 24506618
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.