286 related articles for article (PubMed ID: 25652506)
1. Feasibility of RACT for 3D dose measurement and range verification in a water phantom.
Alsanea F; Moskvin V; Stantz KM
Med Phys; 2015 Feb; 42(2):937-46. PubMed ID: 25652506
[TBL] [Abstract][Full Text] [Related]
2. Acoustic time-of-flight for proton range verification in water.
Jones KC; Vander Stappen F; Sehgal CM; Avery S
Med Phys; 2016 Sep; 43(9):5213. PubMed ID: 27587053
[TBL] [Abstract][Full Text] [Related]
3. Ionoacoustic application of an optical hydrophone to detect proton beam range in water.
Sueyasu S; Takayanagi T; Miyazaki K; Kuriyama Y; Ishi Y; Uesugi T; Unlu MB; Kudo N; Chen Y; Kasamatsu K; Fujii M; Kobayashi M; Rohringer W; Matsuura T
Med Phys; 2023 Apr; 50(4):2438-2449. PubMed ID: 36565440
[TBL] [Abstract][Full Text] [Related]
4. Theoretical detection threshold of the proton-acoustic range verification technique.
Ahmad M; Xiang L; Yousefi S; Xing L
Med Phys; 2015 Oct; 42(10):5735-44. PubMed ID: 26429247
[TBL] [Abstract][Full Text] [Related]
5. Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy.
Assmann W; Kellnberger S; Reinhardt S; Lehrack S; Edlich A; Thirolf PG; Moser M; Dollinger G; Omar M; Ntziachristos V; Parodi K
Med Phys; 2015 Feb; 42(2):567-74. PubMed ID: 25652477
[TBL] [Abstract][Full Text] [Related]
6. Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation.
Faddegon BA; Shin J; Castenada CM; Ramos-Méndez J; Daftari IK
Med Phys; 2015 Jul; 42(7):4199-210. PubMed ID: 26133619
[TBL] [Abstract][Full Text] [Related]
7. Proton beam characterization by proton-induced acoustic emission: simulation studies.
Jones KC; Witztum A; Sehgal CM; Avery S
Phys Med Biol; 2014 Nov; 59(21):6549-63. PubMed ID: 25322212
[TBL] [Abstract][Full Text] [Related]
8. Range verification of a clinical proton beam in an abdominal phantom by co-registration of ionoacoustics and ultrasound.
Schauer J; Wieser HP; Lascaud J; Huang Y; Vidal M; Herault J; Ntziachristos V; Dollinger G; Parodi K
Phys Med Biol; 2023 Jun; 68(12):. PubMed ID: 37220766
[No Abstract] [Full Text] [Related]
9. Spread-out Bragg peak proton FLASH irradiation using a clinical synchrocyclotron: Proof of concept and ion chamber characterization.
Darafsheh A; Hao Y; Zhao X; Zwart T; Wagner M; Evans T; Reynoso F; Zhao T
Med Phys; 2021 Aug; 48(8):4472-4484. PubMed ID: 34077590
[TBL] [Abstract][Full Text] [Related]
10. How proton pulse characteristics influence protoacoustic determination of proton-beam range: simulation studies.
Jones KC; Seghal CM; Avery S
Phys Med Biol; 2016 Mar; 61(6):2213-42. PubMed ID: 26913839
[TBL] [Abstract][Full Text] [Related]
11. Thermoacoustic range verification in the presence of acoustic heterogeneity and soundspeed errors - Robustness relative to ultrasound image of underlying anatomy.
Patch SK; Santiago-Gonzalez D; Mustapha B
Med Phys; 2019 Jan; 46(1):318-327. PubMed ID: 30362132
[TBL] [Abstract][Full Text] [Related]
12. Dose ratio proton radiography using the proximal side of the Bragg peak.
Doolan PJ; Royle G; Gibson A; Lu HM; Prieels D; Bentefour EH
Med Phys; 2015 Apr; 42(4):1871-83. PubMed ID: 25832077
[TBL] [Abstract][Full Text] [Related]
13. Acoustic-based proton range verification in heterogeneous tissue: simulation studies.
Jones KC; Nie W; Chu JCH; Turian JV; Kassaee A; Sehgal CM; Avery S
Phys Med Biol; 2018 Jan; 63(2):025018. PubMed ID: 29176057
[TBL] [Abstract][Full Text] [Related]
14. A novel design of proton computed tomography detected by multiple-layer ionization chamber with strip chambers: A feasibility study with Monte Carlo simulation.
Chen X; Liu R; Zhou S; Sun B; Reynoso FJ; Mutic S; Zhang T; Zhao T
Med Phys; 2020 Feb; 47(2):614-625. PubMed ID: 31705662
[TBL] [Abstract][Full Text] [Related]
15. Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber.
Farace P; Righetto R; Deffet S; Meijers A; Vander Stappen F
Med Phys; 2016 Dec; 43(12):6405. PubMed ID: 27908151
[TBL] [Abstract][Full Text] [Related]
16. Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy.
Min CH; Lee HR; Kim CH; Lee SB
Med Phys; 2012 Apr; 39(4):2100-7. PubMed ID: 22482631
[TBL] [Abstract][Full Text] [Related]
17. Two-stage ionoacoustic range verification leveraging Monte Carlo and acoustic simulations to stably account for tissue inhomogeneity and accelerator-specific time structure - A simulation study.
Patch SK; Hoff DEM; Webb TB; Sobotka LG; Zhao T
Med Phys; 2018 Feb; 45(2):783-793. PubMed ID: 29159885
[TBL] [Abstract][Full Text] [Related]
18. Thermoacoustic range verification using a clinical ultrasound array provides perfectly co-registered overlay of the Bragg peak onto an ultrasound image.
Patch SK; Kireeff Covo M; Jackson A; Qadadha YM; Campbell KS; Albright RA; Bloemhard P; Donoghue AP; Siero CR; Gimpel TL; Small SM; Ninemire BF; Johnson MB; Phair L
Phys Med Biol; 2016 Aug; 61(15):5621-38. PubMed ID: 27385261
[TBL] [Abstract][Full Text] [Related]
19. Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy.
Schellhammer SM; Gantz S; Lühr A; Oborn BM; Bussmann M; Hoffmann AL
Med Phys; 2018 Jul; 45(7):3429-3434. PubMed ID: 29763970
[TBL] [Abstract][Full Text] [Related]
20. Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements.
Bentefour el H; Tang S; Cascio EW; Testa M; Samuel D; Prieels D; Gottschalk B; Lu HM
Med Phys; 2015 Apr; 42(4):1936-47. PubMed ID: 25832084
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]