843 related articles for article (PubMed ID: 25653321)
1. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.
Richter H; Plecko M; Andermatt D; Frigg R; Kronen PW; Klein K; Nuss K; Ferguson SJ; Stöckle U; von Rechenberg B
J Bone Joint Surg Am; 2015 Feb; 97(3):208-15. PubMed ID: 25653321
[TBL] [Abstract][Full Text] [Related]
2. Dynamic Stabilization with Active Locking Plates Delivers Faster, Stronger, and More Symmetric Fracture-Healing.
Bottlang M; Tsai S; Bliven EK; von Rechenberg B; Klein K; Augat P; Henschel J; Fitzpatrick DC; Madey SM
J Bone Joint Surg Am; 2016 Mar; 98(6):466-74. PubMed ID: 26984914
[TBL] [Abstract][Full Text] [Related]
3. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
[TBL] [Abstract][Full Text] [Related]
4. The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy.
Plecko M; Lagerpusch N; Pegel B; Andermatt D; Frigg R; Koch R; Sidler M; Kronen P; Klein K; Nuss K; Gedet P; Bürki A; Ferguson SJ; Stoeckle U; Auer JA; von Rechenberg B
Injury; 2012 Jul; 43(7):1041-51. PubMed ID: 22284334
[TBL] [Abstract][Full Text] [Related]
5. Clinical and radiologic outcomes associated with the use of dynamic locking screws (DLS) in distal tibia fractures.
Acklin YP; Stöckle U; Sommer C
Eur J Trauma Emerg Surg; 2016 Jun; 42(3):351-6. PubMed ID: 26063411
[TBL] [Abstract][Full Text] [Related]
6. The dynamisation of locking plate osteosynthesis by means of dynamic locking screws (DLS)-an experimental study in sheep.
Plecko M; Lagerpusch N; Andermatt D; Frigg R; Koch R; Sidler M; Kronen P; Klein K; Nuss K; Bürki A; Ferguson SJ; Stoeckle U; Auer JA; von Rechenberg B
Injury; 2013 Oct; 44(10):1346-57. PubMed ID: 23182750
[TBL] [Abstract][Full Text] [Related]
7. Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating.
Bottlang M; Tsai S; Bliven EK; von Rechenberg B; Kindt P; Augat P; Henschel J; Fitzpatrick DC; Madey SM
J Orthop Trauma; 2017 Feb; 31(2):71-77. PubMed ID: 27861456
[TBL] [Abstract][Full Text] [Related]
8. Variable fixation promotes callus formation: an experimental study on transverse tibial osteotomies stabilized with locking plates.
Plecko M; Klein K; Planzer K; Wähnert D; Behm P; Ferguson SJ; Brianza S; Stadelmann VA; von Rechenberg B
BMC Musculoskelet Disord; 2020 Dec; 21(1):806. PubMed ID: 33272239
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of mono- and bicortical screws in an experimentally induced gap fracture.
Demner D; Garcia TC; Serdy MG; Hayashi K; Nir BA; Stover SM
Vet Comp Orthop Traumatol; 2014; 27(6):422-9. PubMed ID: 25327936
[TBL] [Abstract][Full Text] [Related]
10. Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating.
Röderer G; Gebhard F; Duerselen L; Ignatius A; Claes L
Injury; 2014 Oct; 45(10):1648-52. PubMed ID: 24813098
[TBL] [Abstract][Full Text] [Related]
11. Fixation of HA-coated unicortical locking screws in a sheep gap model: a comparative biomechanical study.
Moroni A; Pegreffi F; Hoang-Kim A; Tesei F; Giannini S; Wippermann B
J Orthop Trauma; 2008 Jan; 22(1):37-42. PubMed ID: 18176163
[TBL] [Abstract][Full Text] [Related]
12. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.
Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S
Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863
[TBL] [Abstract][Full Text] [Related]
13. Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study.
Travascio F; Buller LT; Milne E; Latta L
Eur J Orthop Surg Traumatol; 2021 Jan; 31(1):121-130. PubMed ID: 32725431
[TBL] [Abstract][Full Text] [Related]
14. The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness.
Döbele S; Horn C; Eichhorn S; Buchholtz A; Lenich A; Burgkart R; Nüssler AK; Lucke M; Andermatt D; Koch R; Stöckle U
Langenbecks Arch Surg; 2010 Apr; 395(4):421-8. PubMed ID: 20358382
[TBL] [Abstract][Full Text] [Related]
15. Plate stabilization with bone rivets: an alternative method for internal fixation of fractures.
Zeiter S; Montavon P; Schneider E; Ito K
J Orthop Trauma; 2004; 18(5):279-85. PubMed ID: 15105749
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
Cullen AB; Curtiss S; Lee MA
J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
[TBL] [Abstract][Full Text] [Related]
17. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.
Madey SM; Tsai S; Fitzpatrick DC; Earley K; Lutsch M; Bottlang M
Iowa Orthop J; 2017; 37():1-10. PubMed ID: 28852327
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical comparison of bicortical locking versus unicortical far-cortex-abutting locking screw-plate fixation for comminuted radial shaft fractures.
Overturf SJ; Morris RP; Gugala Z; Lindsey RW
J Hand Surg Am; 2014 Oct; 39(10):1907-13. PubMed ID: 25149898
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
[TBL] [Abstract][Full Text] [Related]
20. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]